苯基聚合物闪烁体辐射诱导变化中的剂量率效应

Dose rate effects in radiation-induced changes to phenyl-based polymeric scintillators

Christos Papageorgakis, Mohamad Al-Sheikhly, Alberto Belloni, Timothy K. Edberg, Sarah C. Eno, Yongbin Feng, Geng-Yuan Jeng, Abraham Kahn, Yihui Lai, Tyler McDo… 展开作者

Christos Papageorgakis, Mohamad Al-Sheikhly, Alberto Belloni, Timothy K. Edberg, Sarah C. Eno, Yongbin Feng, Geng-Yuan Jeng, Abraham Kahn, Yihui Lai, Tyler McDonnell, Christopher Palmer, Ruhi Perez-Gokhale, Francesca Ricci-Tam, Yao Yao, Zishuo Yang

AI总结:

本文系统研究了剂量率对苯基聚合物闪烁体辐射损伤的影响,发现剂量常数与剂量率对数近似线性相关,并揭示了不同基质、荧光剂和厚度下光输出损伤与色心形成的相对贡献。

摘要:

本文给出了电离辐射对Eljen Technology公司生产的塑料闪烁棒信号产生的影响结果,涵盖了不同的基质材料、掺杂浓度、荧光剂(EJ-200和EJ-260)、抗氧化剂浓度、闪烁体厚度、剂量和剂量率。辐照前后的光输出使用α源和光电倍增管测量,光透射率使用分光光度计测量。假设光输出随剂量呈指数下降,光输出的变化用指数剂量常数$D$来量化。对于1倍和2倍的主掺杂和次掺杂浓度,以及0倍、1倍和2倍抗氧化剂浓度(制造商默认浓度),$D$值相似。对于所有材料,在2.2 Gy/hr至70 Gy/hr的剂量率范围内,$D$值近似线性地依赖于剂量率的对数。对于EJ-200聚乙烯基甲苯基(PVT)闪烁体,剂量常数在高达3400 Gy/hr的剂量率范围内近似与剂量率的对数成线性关系,而对于聚苯乙烯基(PS)闪烁体或使用EJ-260荧光剂的两种材料,在约100 Gy/hr以上,剂量常数保持不变或下降(取决于掺杂浓度)。不同厚度闪烁棒和不同荧光剂的结果表明,对于厚度$\leq1$ cm的闪烁体,初始光输出的损伤比色心形成的影响更大。对于蓝色闪烁体(EJ-200),透射率测量表明荧光剂受到了损伤。我们还发现,对于EJ-200荧光剂,在剂量率高于约100 Gy/hr时,PVT比PS更耐辐射损伤,但在较低剂量率下以及使用EJ-260荧光剂时,它们表现出相似的损伤。

英文摘要:

Results on the effects of ionizing radiation on the signal produced by plastic scintillating rods manufactured by Eljen Technology company are presented for various matrix materials, dopant concentrations, fluors (EJ-200 and EJ-260), anti-oxidant concentrations, scintillator thickness, doses, and dose rates. The light output before and after irradiation is measured using an alpha source and a photomultiplier tube, and the light transmission by a spectrophotometer. Assuming an exponential decrease in the light output with dose, the change in light output is quantified using the exponential dose constant $D$. The $D$ values are similar for primary and secondary doping concentrations of 1 and 2 times, and for antioxidant concentrations of 0, 1, and 2 times, the default manufacturer's concentration. The $D$ value depends approximately linearly on the logarithm of the dose rate for dose rates between 2.2 Gy/hr and 70 Gy/hr for all materials. For EJ-200 polyvinyltoluene-based (PVT) scintillator, the dose constant is approximately linear in the logarithm of the dose rate up to 3400 Gy/hr, while for polystyrene-based (PS) scintillator or for both materials with EJ-260 fluors, it remains constant or decreases (depending on doping concentration) above about 100 Gy/hr. The results from rods of varying thickness and from the different fluors suggest damage to the initial light output is a larger effect than color center formation for scintillator thickness $\leq1$ cm. For the blue scintillator (EJ-200), the transmission measurements indicate damage to the fluors. We also find that while PVT is more resistant to radiation damage than PS at dose rates higher than about 100 Gy/hr for EJ-200 fluors, they show similar damage at lower dose rates and for EJ-260 fluors.