arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2201.09279physics.ins-dethep-ex
收藏

利用时间过阈值信息改进RPC探测器的时间和位置分辨率

Improving Time and Position Resolution of RPC detectors using Time Over Threshold Information

Jim M John, S. Pethuraj, G. Majumder, K. C. Ravindran, V. M. Datar, B. Satyanarayana

AI总结:

该研究利用时间过阈值信息改进INO-ICAL实验中RPC探测器的时间和位置分辨率,以提升中微子动量和方向性测量精度。

摘要:

INO-ICAL是一项拟议中的地下粒子物理实验,旨在通过探测大气空气簇射中产生的中微子来研究中微子振荡参数。铁量热器(ICAL)将由151层垂直堆叠的铁层组成,铁层之间放置有源探测器元件。铁层将被磁化,以便能够测量由ν_μ(或反ν_μ)相互作用产生的μ^-(或μ^+)的动量和电荷。阻性板室(RPCs)被选为有源探测器元件,因为它们具有大面积覆盖、无妥协的灵敏度、数十年来一致稳定的性能以及成本效益。决定ICAL实验物理潜力的主要因素是大面积RPC的效率、位置分辨率和时间分辨率。一个名为miniICAL的原型探测器(包含11层铁)已投入使用,以了解建造大规模磁铁及其辅助系统所面临的工程挑战,并研究由INO合作组织开发的RPC探测器和读出电子学的性能。作为RPC探测器性能研究的一部分,我们尝试改进它们的位置和时间分辨率。即使位置和时间分辨率的微小改进也将有助于改善ICAL中中微子动量和方向性的测量。RPC脉冲(信号)的时间过阈值(ToT)由读出电子学记录。ToT是脉冲宽度并因此是振幅的度量。该信息被用于改进RPC的时间分辨率和位置分辨率,从而提升INO的物理潜力。

英文摘要:

INO-ICAL is a proposed underground particle physics experiment to study the neutrino oscillation parameters by detecting neutrinos produced in the atmospheric air showers. Iron CALorimeter (ICAL) is to have 151 layers of iron stacked vertically, with active detector elements in between the iron layers. The iron layers will be magnetized to enable the measurement of momentum and charge of the $μ^-$ (or $μ^+$) produced by $ν_μ$ (or $\barν_μ$) interactions. Resistive Plate Chambers (RPCs) have been chosen as the active detector elements due to their large area coverage, uncompromised sensitivity, consistent performance for decades, as well as cost effectiveness. The major factors that decide the physics potential of the ICAL experiment are efficiency, position resolution and time resolution of the large area RPCs. A prototype detector called miniICAL (with 11 iron layers) was commissioned to understand the engineering challenges in building the large scale magnet and its ancillary systems, and also to study the performance of the RPC detectors and readout electronics developed by the INO collaboration. As part of the performance study of the RPC detectors, an attempt is made to improve the position and time resolution of them. Even a small improvement in the position and time resolution will help to improve the measurements of momentum and directionality of the neutrinos in ICAL. The Time-over-Threshold (ToT) of the RPC pulses (signals) is recorded by the readout electronics. ToT is a measure of the pulse width and consequently the amplitude. This information is used to improve the time and position resolution of the RPCs and consequently INO physics potential.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑