With steadily increasing wind turbine penetration, regulatory standards for grid interconnection are evolving to require that wind generation systems ride-through disturbances such as faults and support the grid during such events. Conventional modifications to the doubly fed induction generation (DFIG) architecture for providing ride-through result in limited control of the turbine shaft and grid current during fault events. A DFIG architecture in which the grid side converter is connected in series as opposed to parallel with the grid connection has shown improved low voltage ride through but poor power processing capabilities. In this paper a unified DFIG wind turbine architecture which employs a parallel grid side rectifier and series grid side converter is presented. The combination of these two converters enables unencumbered power processing and improved voltage disturbance ride through. A dynamic model and control structure for this unified architecture is developed. The operation of the system is illustrated using computer simulations.
This paper proposes a novel integrated multiport bidirectional back-to-back power converter for a type-4 wind turbine that accommodates a battery and supercapacitor for energy storage. The circuit topology reduces 4 switches compared to the traditional configuration. Moreover, owing to the dual-buck structure embedded in the phase leg, the circuitry has no short-circuit path, therefore it withstands short-circuited events for a much longer time than the normal phase-leg and prevents the reverse current in turn-off recovery. The use of a hybrid energy storage system with battery and supercapaci…
In this work we present a novel dual-port grid-forming control strategy, for permanent magnet synchronous generator wind turbines with back-to-back voltage source converters, that unifies the entire range of functions from maximum power point tracking (MPPT) to providing inertia and fast frequency response without explicit mode switching between grid-following and grid-forming control. The controls impose a well-defined AC voltage at the grid-side converter (GSC) and the machine-side converter (MSC) AC terminals and explicitly stabilize the DC-link capacitor voltage through both GSC and MSC. T…
This paper presents the development of a non-linear model predictive controller (MPC) for controlling variable speed hydropower (VSHP) plants. The MPC coordinates the turbine controller with the virtual synchronous generator (VSG) control of the power electronics converter to optimize the plant's performance. The main objective is to deliver a fast power response to frequency deviations by utilizing the kinetic energy of the turbine and generator. This is made possible by allowing the turbine rotational speed to deviate temporarily from its optimal speed. In addition, the efficiency should be …
Wind turbine condition monitoring based on intra- and inter-farm federated learning
Bern University of Applied Sciences, School of Engineering(伯恩应用科学大学工程学院);Università della Svizzera italiana, Faculty of Informatics(瑞士联合大学信息学院);Delft University of Technology, Department of Geoscience(代尔夫特理工大学地质学院);Remote Sensing, Stevinweg 1, 2628 Delft, The Netherlands(遥感学院,Stevinweg 1,2628 Delft,荷兰)
In this work, an advanced motion controller is proposed for buck converter-fed DC motor systems. The design is based on an idea of active disturbance rejection control (ADRC) with its key component being a custom observer capable of reconstructing various types of disturbances (including complex, harmonic signals). A special formulation of the proposed design allows the control action to be expressed in a concise and practically appealing form reducing its implementation requirements. The obtained experimental results show increased performance of the introduced approach over conventionally us…
Current-fed half bridge converter with bidirectional switches on ac side and a full bridge converter on dc side of a high frequency transformer is an optimal topology for single stage galvanically isolated ac-dc converter for onboard vehicle charging application. AC side switches are actively commutated to achieve zero current switching (ZCS) using single phase shift modulation (SPSM) and discontinuous current phase shift modulation (DCPSM). Furthermore, zero voltage turn-on (ZVS) is achieved for dc side switches. Compared to SPSM, DCPSM maintains a constant peak current in the converter throu…
The current paper presents a Sliding Mode Controller (SMC) for indirect field-oriented Cascaded Doubly Fed Induction Generator (CDFIG) powered through a Matrix Converter (MC). The proposed SMC employs a continuous control strategy to accomplish free chattering fractional-order sliding-mode control and to ensure that the control of the first DFIG stator's reactive and active power is separated. An MC is used to control the current provided to the second stator of the CDFIG as an alternative to standard voltage source inverters. The two MCs are controlled via Space-Vector Pulse-Width Modulation …
Rising wind energy integration, accompanied by a decreasing level of system inertia, requires additional sources of ancillary services. Wind turbines based on doubly fed induction generators (DFIG) can provide inertial and primary frequency support, when equipped with specific controls. This paper investigates the effect of frequency support provision by DFIGs on the small-signal stability of power systems. To this end, a modified version of the Kundur two-area test system is employed to analyze different scenarios. Wind energy generation is either added to the existing system or displaces par…
In this paper, a new fault tolerant dc-ac converter-fed induction motor drive is proposed to maintain motor as close as possible to its desired normal operation under open- and short-circuit switch failures. The operational principles for fault detection and isolation schemes are provided. Two control strategies including predictive control and voltage mode-controlled PWM with integral-double-lead controller for two stage of the converter are presented in conjunction with the elaborated discussion. The control strategy determines appropriate switching states for continuous operation of the dri…
The undergoing transition from conventional to converter-interfaced renewable generation leads to significant challenges in maintaining frequency stability due to declining system inertia. In this paper, a novel control framework for Synthetic Inertia (SI) provision from Wind Turbines (WTs) is proposed, which eliminates the secondary frequency dip and allows the dynamics of SI from WTs to be analytically integrated into the system frequency dynamics. Furthermore, analytical system frequency constraints with SI provision from WTs are developed and incorporated into a stochastic system schedulin…
In recent years, the use of multilevel inverter has become popular due to its many advantages. Due to the popularity of multilevel inverters in industries and in applications that require a wide range of voltages, there have been many challenges to achieve high-quality voltage. Many pieces of research have been done to solve the problem of annoying harmonics in multilevel inverters. In this study, pulse width modulation (PWM) has been proposed as a switching method. Using the Selective Harmonic Elimination (SHE) technique, the inverter switching can be carried out in low frequency, and also, t…
Modern power systems present low levels of inertia due to the growing shares of converter-interfaced generation. Consequently, renewable energy sources are increasingly requested to provide frequency support. In addition, due to the inertia loss, the requirements regarding frequency containment reserves (FCR) are becoming tough to meet with traditional units such as hydro, whose non-minimum phase (NMP) characteristic reduces the closed-loop stability margins. The shortcomings of traditional synchronous generation motivates new protocols for fast frequency reserves (FFR). In this work, we desig…
A major concern associated to the massive connection of distributed energy resources is the increasing share of power electronic interfaces resulting in the global inertia reduction of power systems. The recent literature advocated the use of voltage source converter (VSC) interfaced battery energy storage system (BESS) as a potential way to counterbalance this lack of inertia. However, the impact of VSCs on the dynamics of reduced-inertia grids is not well understood especially with respect to large transmission grids interfacing a mix of rotating machines and resources interfaced with power …
This paper proposes a novel coordinating mechanism between synchronous generators (SGs) and wind turbines (WTs) based on doubly-fed induction generators (DFIGs) for enhanced primary frequency regulation. WTs are urged to participate on frequency regulation, specially if wind power penetration keeps increasing. WTs control support is possible, but it is transient due to the WTs lack of energy storage. This drawback can result in either a further delayed response from the governors of SGs or further frequency decay when WTs support is over. The proposed coordination attempt to tackle this issue.…
With increased wind power penetration in modern power systems, wind plants are required to provide frequency support similar to conventional plants. However, for the existing frequency regulation scheme of wind turbines, the control gains in the auxiliary frequency controller are difficult to set because of the compromise of the frequency regulation performance and the stable operation of wind turbines, especially when the wind speed remains variable. This paper proposes a novel frequency regulation scheme (FRS) for de-loaded wind turbines. Instead of an auxiliary frequency controller, frequen…
With the increasing interest in converter-fed islanded microgrids, particularly for resilience, it is becoming more critical to understand the dynamical behavior of these systems. This paper takes a holistic view of grid-forming converters and considers control approaches for both modeling and regulating the DC-link voltage when the DC-source is a battery energy storage system. We are specifically interested in understanding the performance of these controllers, subject to large load changes, for decreasing values of the DC-side capacitance. We consider a fourth, second, and zero-order model o…
There is an ongoing trend of reduction in short circuit power at the grid connection point due to decommissioning of synchronous generation plants causing system strength issues in wind power plants. Whereas wind power plant rating and export cable length are increasing, further weakening the system strength and accompanied by stability challenges. Under such a scenario, a grid forming control demonstrated to operate in a weaker system has value creation potential for application in wind turbine generators. In addition, the grid forming control can also enable a wind power plant to operate in …
This paper proposes a new non-iterative time-domain simulation approach using Differential Transform Method (DTM) to solve the set of non-linear Differential-Algebraic Equations (DAEs) involved in a DFIG-based wind power system. The DTM is an analytical as well as numerical approach applied to solve high dimensional non-linear dynamical systems and the solution can be expressed in the form of a series. In this approach, there is no need to compute higher-order derivatives as DAEs are converted into a set of linear equations after applying transformation rules so that the power series coefficie…