基于投影域的视点一致性金属分割在CBCT中的应用--一种潜在的改进方法

View-Consistent Metal Segmentation in the Projection Domain for Metal Artifact Reduction in CBCT -- An Investigation of Potential Improvement

Friedrich-Alexander University Erlangen-Nuremberg(埃尔朗根-纽伦堡大学);Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander University Erlangen-Nuremberg(埃尔朗根-纽伦堡大学先进光学技术研究生院);Siemens Healthcare GmbH(西门子医疗有限公司)

Tristan M. Gottschalk, Andreas Maier, Florian Kordon, Björn W. Kreher

摘要:

创伤干预的积极结果取决于对插入的金属植入物的术中评估。由于金属伪影的出现,该评估的质量在很大程度上取决于所谓的金属伪影减少方法(MAR)的性能。这些MAR方法中的大多数需要预先分割插入的金属物体。因此,通常在重建的3D体积中应用相当简单的基于阈值的分割方法,尽管存在一些主要缺点。通过该出版物,研究了将分割任务转移到基于学习的、基于视图一致的2D投影的方法对下游MAR结果的潜在影响。为了分割本金属,一个相当简单的学习为基础的2D投影明智的分割网络,使用在尸体研究过程中获得的真实数据进行训练,检查。为了克服2D投影分割带来的缺点,提出了一致性过滤器。移位的分割域的影响进行了研究,通过比较标准fsMAR与修改后的fsMAR版本使用新的分割掩模的结果。通过对真实尸体数据的定量和定性评价,所研究的方法显示出增加的MAR性能和对金属伪影的高度不敏感性。对于金属在重建的FoV之外的病例或金属消失的病例,可以显示伪影的显著减少。因此,增加高达约3 dB w.r.t.实现了所有切片上的平均PSNR度量和单个切片的高达9dB。所示的结果揭示了转移到基于2D的分割方法对实际数据的有益影响,用于下游使用MAR方法,如fsMAR。

英文摘要:

The positive outcome of a trauma intervention depends on an intraoperative evaluation of inserted metallic implants. Due to occurring metal artifacts, the quality of this evaluation heavily depends on the performance of so-called Metal Artifact Reduction methods (MAR). The majority of these MAR methods require prior segmentation of the inserted metal objects. Therefore, typically a rather simple thresholding-based segmentation method in the reconstructed 3D volume is applied, despite some major disadvantages. With this publication, the potential of shifting the segmentation task to a learning-based, view-consistent 2D projection-based method on the downstream MAR's outcome is investigated. For segmenting the present metal, a rather simple learning-based 2D projection-wise segmentation network that is trained using real data acquired during cadaver studies, is examined. To overcome the disadvantages that come along with a 2D projection-wise segmentation, a Consistency Filter is proposed. The influence of the shifted segmentation domain is investigated by comparing the results of the standard fsMAR with a modified fsMAR version using the new segmentation masks. With a quantitative and qualitative evaluation on real cadaver data, the investigated approach showed an increased MAR performance and a high insensitivity against metal artifacts. For cases with metal outside the reconstruction's FoV or cases with vanishing metal, a significant reduction in artifacts could be shown. Thus, increases of up to roughly 3 dB w.r.t. the mean PSNR metric over all slices and up to 9 dB for single slices were achieved. The shown results reveal a beneficial influence of the shift to a 2D-based segmentation method on real data for downstream use with a MAR method, like the fsMAR.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑