arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2111.05790eess.IVcs.AIcs.CVcs.LGphysics.med-ph

早期心肌梗死多视图超声心动图检测

Early Myocardial Infarction Detection over Multi-view Echocardiography

Tampere University(坦佩雷大学);Qatar University(卡塔尔大学);Hamad Medical Corporation(哈马德医疗公司)

Aysen Degerli, Serkan Kiranyaz, Tahir Hamid, Rashid Mazhar, Moncef Gabbouj

AI总结:

本研究提出融合A4C和A2C视图的多视图超声心动图方法,利用主动多项式估计左心室壁运动,通过机器学习分类器检测心肌梗死,在260个记录上达到90.91%灵敏度和86.36%精确度。

摘要:

心肌梗死(MI)是全球范围内导致死亡的主要原因,其发生是由于供应心肌的冠状动脉阻塞所致。早期诊断心肌梗死及其定位可以通过促进早期治疗干预来减轻心肌损伤的程度。冠状动脉阻塞后,缺血心肌节段的区域性室壁运动异常(RWMA)是最早出现的变化。超声心动图是评估任何RWMA的基本工具。仅从单个超声心动图视图评估左心室(LV)壁的运动可能会导致心肌梗死诊断的遗漏,因为RWMA可能在该特定视图上不可见。因此,在本研究中,我们提出融合心尖四腔(A4C)和心尖两腔(A2C)视图,其中总共可以分析12个心肌节段用于心肌梗死检测。所提出的方法首先通过主动多项式(APs)估计左心室壁的运动,这些多项式提取并跟踪心内膜边界以计算心肌节段位移。从A4C和A2C视图位移中提取特征,这些特征被拼接并输入分类器以检测心肌梗死。本研究的主要贡献包括:1)通过包含A4C和A2C视图共260个超声心动图记录创建了一个新的基准数据集,该数据集已公开共享给研究社区;2)通过基于机器学习的方法改进了先前基于阈值的APs工作的性能;3)通过融合A4C和A2C视图的信息,开创了一种通过多视图超声心动图检测心肌梗死的方法。实验结果表明,所提出的方法在多视图超声心动图上实现了90.91%的灵敏度和86.36%的精确度用于心肌梗死检测。软件实现已在https://github.com/degerliaysen/MultiEchoAI上共享。

英文摘要:

Myocardial infarction (MI) is the leading cause of mortality in the world that occurs due to a blockage of the coronary arteries feeding the myocardium. An early diagnosis of MI and its localization can mitigate the extent of myocardial damage by facilitating early therapeutic interventions. Following the blockage of a coronary artery, the regional wall motion abnormality (RWMA) of the ischemic myocardial segments is the earliest change to set in. Echocardiography is the fundamental tool to assess any RWMA. Assessing the motion of the left ventricle (LV) wall only from a single echocardiography view may lead to missing the diagnosis of MI as the RWMA may not be visible on that specific view. Therefore, in this study, we propose to fuse apical 4-chamber (A4C) and apical 2-chamber (A2C) views in which a total of 12 myocardial segments can be analyzed for MI detection. The proposed method first estimates the motion of the LV wall by Active Polynomials (APs), which extract and track the endocardial boundary to compute myocardial segment displacements. The features are extracted from the A4C and A2C view displacements, which are concatenated and fed into the classifiers to detect MI. The main contributions of this study are 1) creation of a new benchmark dataset by including both A4C and A2C views in a total of 260 echocardiography recordings, which is publicly shared with the research community, 2) improving the performance of the prior work of threshold-based APs by a Machine Learning based approach, and 3) a pioneer MI detection approach via multi-view echocardiography by fusing the information of A4C and A2C views. Experimental results show that the proposed method achieves 90.91% sensitivity and 86.36% precision for MI detection over multi-view echocardiography. The software implementation is shared at https://github.com/degerliaysen/MultiEchoAI.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑