减少四极谐振器中的寄生损耗,从而能够直接测量SRF样品的低残余电阻
Mitigation of parasitic losses in the quadrupole resonator enabling direct measurements of low residual resistances of SRF samples
摘要:
四极谐振器(QPR)是一种专用的样品测试腔,用于在宽的温度、RF场和频率范围内对超导样品进行RF表征。它的主要用途是高分辨率测量表面电阻,由于第一工作四极模式的低频,可以直接获得残余电阻。除了众所周知的高分辨率的QPR,偏置的测量数据向更高的值已被观察到,特别是在高次谐波四极模。数值研究表明,这可以解释为寄生的RF损耗的适配器法兰用于安装样品到QPR。在暴露于RF场的不锈钢凸缘的那些表面上涂覆几微米的铌显著地降低了这种偏置,使得能够在2 K和413 MHz下直接测量小于5 n $Ω$的残余电阻。基于模拟的恒定校正是不可行的,因为从一个测量到另一个测量存在偏差。然而,鉴于这些新结果,这个问题得到了解决。
英文摘要:
The quadrupole resonator (QPR) is a dedicated sample-test cavity for the RF characterization of superconducting samples in a wide temperature, RF field and frequency range. Its main purpose are high resolution measurements of the surface resistance with direct access to the residual resistance thanks to the low frequency of the first operating quadrupole mode. Besides the well-known high resolution of the QPR, a bias of measurement data towards higher values has been observed, especially at higher harmonic quadrupole modes. Numerical studies show that this can be explained by parasitic RF losses on the adapter flange used to mount samples into the QPR. Coating several micrometer of niobium on those surfaces of the stainless steel flange that are exposed to the RF fields significantly reduced this bias, enabling a direct measurement of a residual resistance smaller than 5 n$Ω$ at 2 K and 413 MHz. A constant correction based on simulations was not feasible due to deviations from one measurement to another. However, this issue is resolved given these new results.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。