P. J. Hobson, J. Vovrosh, B. Stray, M. Packer, J. Winch, N. Holmes, F. Hayati, K. McGovern, R. Bowtell, M. J. Brookes, K. Bongs, T. M. Fromhold, M. Holynski

摘要:

基于冷原子的量子传感器正在开发中,其测量精度前所未有。由于原子能级的变化,量子传感器通常对其内部磁场环境有严格的要求。通常,使用高磁导率磁屏蔽来衰减背景磁场,其中消除残余磁场并引入利用屏蔽内的线圈实现的量化场。然而,高磁导率屏蔽会使所有磁场失真,包括传感器内部产生的磁场。在这里,我们展示了一种解决方案,通过设计多个线圈覆盖在3D打印的线圈架上,在冷原子干涉仪的带帽圆柱形磁屏蔽内产生三个均匀和三个恒定的线性梯度磁场。这些磁场在现场进行表征,并以高精度匹配其所需的形式。例如,均匀横向场$B_x$在大于$40$ %的屏蔽长度上偏离小于$0.2$ %。我们还直接使用冷原子映射场,并研究线圈系统的潜力,以减少二次塞曼效应的偏差。这种线圈设计技术能够在大的空间体积上进行有针对性的场补偿,并有可能减少许多冷原子系统中的系统偏移和噪声。

英文摘要:

Quantum sensors based on cold atoms are being developed which produce measurements of unprecedented accuracy. Due to shifts in atomic energy levels, quantum sensors often have stringent requirements on their internal magnetic field environment. Typically, background magnetic fields are attenuated using high permeability magnetic shielding, with the cancelling of residual and introduction of quantisation fields implemented with coils inside the shield. The high permeability shield, however, distorts all magnetic fields, including those generated inside the sensor. Here, we demonstrate a solution by designing multiple coils overlaid on a 3D-printed former to generate three uniform and three constant linear gradient magnetic fields inside the capped cylindrical magnetic shield of a cold atom interferometer. The fields are characterised in-situ and match their desired forms to high accuracy. For example, the uniform transverse field, $B_x$, deviates by less than $0.2$% over more than $40$% of the length of the shield. We also map the field directly using the cold atoms and investigate the potential of the coil system to reduce bias from the quadratic Zeeman effect. This coil design technology enables targeted field compensation over large spatial volumes and has the potential to reduce systematic shifts and noise in numerous cold atom systems.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑