长方体磁屏蔽线圈间距优化的三步模型
A Three-step Model for Optimizing Coil Spacings Inside Cuboid-shaped Magnetic Shields
摘要:
提出了一种计算磁屏蔽室内线圈产生的磁场的三步模型。屏蔽被建模为两个无限宽的平行板和一个无限高的管。本文提出了一种改进的镜像法,它考虑了有限厚度平行板的影响。通过有限元模拟,引入了反应因子来描述竖管的影响。应用改进的镜像法,将计算结果与反应因子相乘,可快速计算出屏蔽体内的磁通量密度。用有限元法和超导量子干涉装置测量磁流变阻尼器内亥姆霍兹线圈的磁场,对三步模型进行了验证。该模型允许屏蔽耦合线圈间距的快速优化相比,重复耗时的有限元计算。作为一个例子,我们优化了两个平行的方形线圈之间的距离连接到MSR的墙壁。对边长为2.75 m的线圈原型进行了测量,在场强为2.7 \textmu T时,中心5 cm处的磁场变化为18 pT。所获得的6~ppm的相对场变化比我们以前使用的亥姆霍兹线圈小5.4倍。
英文摘要:
A three-step model for calculating the magnetic field generated by coils inside cuboid-shaped shields like magnetically shielded rooms (MSRs) is presented. The shield is modelled as two parallel plates of infinite width and one tube of infinite height. We propose an improved mirror method which considers the effect of the parallel plates of finite thickness. A reaction factor is introduced to describe the influence of the vertical tube, which is obtained from finite element method (FEM) simulations. By applying the improved mirror method and then multiplying the result with the reaction factor, the magnetic flux density within the shielded volume can be determined in a fast computation. The three-step model is verified both with FEM and measurements of the field of a Helmholtz coil inside an MSR with a superconducting quantum interference device. The model allows a fast optimization of shield-coupled coil spacings compared to repetitive time-consuming FEM calculations. As an example, we optimize the distance between two parallel square coils attached to the MSR walls. Measurements of a coil prototype of 2.75~m in side length show a magnetic field change of 18~pT over the central 5~cm at the field strength of 2.7~\textmu T. This obtained relative field change of 6~ppm is a factor of 5.4 smaller than our previously used Helmholtz coil.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。