GECAM上多个SiPM-based gamma-ray检测器的增益稳定和一致性校正方法
Gain stabilization and consistency correction approach for multiple SiPM-based gamma-ray detectors on GECAM
摘要:
引力波高能电磁对应物全天监测器(GECAM,飞行任务)的每颗卫星都由25个基于SiPM的伽马射线探测器组成。虽然SiPM GRD具有体积小、偏压低等优点,但SiPM增益随温度的漂移是影响GRD性能的一个严重问题。设计了一种自适应电压源,用于自动调节SiPM偏置电压,以补偿温度效应并保持增益稳定。该方法在地面和空中试验中均被证明是有效的。飞行中测量的SiPM增益的变化在2%以内。为了减小GRD的增益不均匀性,提出并实现了一种迭代偏置电压调整方法。增益非均匀性从17%降低到0.6%。本文详细讨论了增益稳定和一致性校正方法。
英文摘要:
Each satellite of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM, mission) consists of 25 SiPM based gamma-ray detectors (GRDs). Although SiPM based GRD has merits of compact size and low bias-voltage, the drift of the SiPM gain with temperature is a severe problem for GRD performance. An adaptive voltage supply source was designed to automatically adjust the SiPM bias voltage to compensate the temperature effects and keep the gain stable. This approach has been proved to be effective during both the on-ground and in-flight tests. The in-flight measured variation of the SiPM gain is within 2%. To reduce the gain non-uniformity of GRDs, an iterative bias voltage adjustment approach is proposed and implemented. The gain non-uniformity is reduced from 17% to 0.6%. In this paper, the gain stabilization and consistency correction approach are presented and discussed in detail.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。