JWST MIRI中分辨光谱仪的波长定标和分辨本领

Wavelength Calibration and Resolving Power of the JWST MIRI Medium Resolution Spectrometer

A. Labiano, I. Argyriou, J. Alvarez-Marquez, A. Glasse, A. Glauser, P. Patapis, D. Law, B. R. Brandl, K. Justtanont, F. Lahuis, J. R. Martinez-Galarza, M. Muell… 展开作者

A. Labiano, I. Argyriou, J. Alvarez-Marquez, A. Glasse, A. Glauser, P. Patapis, D. Law, B. R. Brandl, K. Justtanont, F. Lahuis, J. R. Martinez-Galarza, M. Mueller, A. Noriega-Crespo, P. Royer, B. Shaughnessy, B. Vandenbussche

摘要:

JWST上的中红外仪器(MIRI)将在中红外波长范围内以前所未有的灵敏度水平提供成像,日冕照相,低分辨率光谱和中分辨率光谱。MIRI的中分辨率光谱仪(MRS)是一种积分场光谱仪,可在13至56平方英寸的FOV范围内提供4.9至28.3 μ m的衍射极限光谱。从地面测试,我们计算的物理参数基本的一般观察者和校准的波长解决方案和分辨率的MRS的能力是至关重要的,最大限度地提高仪器的科学性能。我们已经使用了地面观测的离散光谱特征与法布里-珀罗标准具光谱相结合,以表征的波长解决方案和光谱分辨率的MRS。我们提出的方法来获得MRS光谱表征,其中包括精确的波长覆盖的每个MRS子带,计算的分辨率作为波长的函数,和测量切片相关的光谱失真。分辨率从通道1的R3500到通道4的R1500不等。基于地面测试数据,波长校准精度被估计为低于十分之一像素,由于未分辨源的切片内的目标位置而具有小的系统偏移,其具有约0.25光谱分辨率元素的最大幅度。根据地面测试数据,MRS符合其设计的R和波长精度的光谱要求。我们还提出了调试策略和目标,将遵循更新MRS的光谱表征。

英文摘要:

The Mid-Infrared Instrument (MIRI) on-board JWST will provide imaging, coronagraphy, low-resolution spectroscopy and medium-resolution spectroscopy at unprecedented sensitivity levels in the mid-infrared wavelength range. The Medium-Resolution Spectrometer (MRS) of MIRI is an integral field spectrograph that provides diffraction-limited spectroscopy between 4.9 and 28.3 um, within a FOV varying from 13 to 56" square. From ground testing, we calculate the physical parameters essential to general observers and calibrating the wavelength solution and resolving power of the MRS is critical for maximising the scientific performance of the instrument. We have used ground-based observations of discrete spectral features in combination with Fabry-Perot etalon spectra to characterize the wavelength solution and spectral resolving power of the MRS. We present the methodology used to derive the MRS spectral characterisation, which includes the precise wavelength coverage of each MRS sub-band, computation of the resolving power as a function of wavelength, and measuring slice-dependent spectral distortions. The resolving power varies from R3500 in channel 1 to R1500 in channel 4. Based on the ground test data, the wavelength calibration accuracy is estimated to be below one tenth of a pixel, with small systematic shifts due to the target position within a slice for unresolved sources, that have a maximum amplitude of about 0.25 spectral resolution elements. Based on ground test data, the MRS complies with the spectral requirements for both the R and wavelength accuracy for which it was designed. We also present the commissioning strategies and targets that will be followed to update the spectral characterisation of the MRS.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑