arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2109.00802physics.med-phcs.CVcs.LG
收藏

解剖引导注意力增强无监督PET图像去噪性能

Anatomical-Guided Attention Enhances Unsupervised PET Image Denoising Performance

Hamamatsu Photonics K. K.(滨松光子学株式会社);Hamamatsu University School of Medicine(滨松医科大学)

Yuya Onishi, Fumio Hashimoto, Kibo Ote, Hiroyuki Ohba, Ryosuke Ota, Etsuji Yoshikawa, Yasuomi Ouchi

摘要:

尽管监督卷积神经网络(CNN)在对正电子发射断层成像(PET)图像进行去噪方面通常优于传统的替代方案,但它们需要许多低质量和高质量的参考PET图像对。本文提出了一种基于解剖信息引导注意机制的无监督三维PET图像去噪方法。提出的磁共振引导深度解码器(MR-GDD)通过引入编码器-解码器和深度解码器子网络,更有效地利用MR引导图像的空间细节和语义特征。此外,引导图像的特定形状和图案不影响去噪的PET图像,因为引导图像通过注意门输入到网络。在[ $^{18}$ F]氟代-2-脱氧-D-葡萄糖(FDG)的蒙特卡罗模拟中,所提出的方法获得了最高的峰信噪比和结构相似性(27.92 $\pm$ 0.44 dB/0.886 $\pm$ 0.007),与高斯滤波相比(26.68 $\pm$ 0.10 dB/0.807 $\pm$ 0.004),图像引导滤波(27.40 $\pm$ 0.11 dB/0.849 $\pm$ 0.003),深度图像先验(DIP)(24.22 $\pm$ 0.43 dB/0.737 $\pm$ 0.017)和MR-DIP(27.65 $\pm$ 0.42 dB/0.879 $\pm$ 0.007)。此外,我们通过实验可视化了优化过程的行为,这在无监督的基于CNN的恢复问题中通常是未知的。对于临床前(使用[ $^{18}$ F]FDG和[ $^{11}$ C]雷氯必利)和临床(使用[ $^{18}$ F]florbetapir)研究,所提出的方法证明了最先进的去噪性能,同时保留了空间分辨率和定量准确性,尽管使用了具有全计数1/10的各种噪声PET图像的通用网络架构。这些结果表明,所提出的MR-GDD可以大大减少PET扫描时间和PET示踪剂剂量,而不会影响患者。

英文摘要:

Although supervised convolutional neural networks (CNNs) often outperform conventional alternatives for denoising positron emission tomography (PET) images, they require many low- and high-quality reference PET image pairs. Herein, we propose an unsupervised 3D PET image denoising method based on an anatomical information-guided attention mechanism. The proposed magnetic resonance-guided deep decoder (MR-GDD) utilizes the spatial details and semantic features of MR-guidance image more effectively by introducing encoder-decoder and deep decoder subnetworks. Moreover, the specific shapes and patterns of the guidance image do not affect the denoised PET image, because the guidance image is input to the network through an attention gate. In a Monte Carlo simulation of [$^{18}$F]fluoro-2-deoxy-D-glucose (FDG), the proposed method achieved the highest peak signal-to-noise ratio and structural similarity (27.92 $\pm$ 0.44 dB/0.886 $\pm$ 0.007), as compared with Gaussian filtering (26.68 $\pm$ 0.10 dB/0.807 $\pm$ 0.004), image guided filtering (27.40 $\pm$ 0.11 dB/0.849 $\pm$ 0.003), deep image prior (DIP) (24.22 $\pm$ 0.43 dB/0.737 $\pm$ 0.017), and MR-DIP (27.65 $\pm$ 0.42 dB/0.879 $\pm$ 0.007). Furthermore, we experimentally visualized the behavior of the optimization process, which is often unknown in unsupervised CNN-based restoration problems. For preclinical (using [$^{18}$F]FDG and [$^{11}$C]raclopride) and clinical (using [$^{18}$F]florbetapir) studies, the proposed method demonstrates state-of-the-art denoising performance while retaining spatial resolution and quantitative accuracy, despite using a common network architecture for various noisy PET images with 1/10th of the full counts. These results suggest that the proposed MR-GDD can reduce PET scan times and PET tracer doses considerably without impacting patients.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑