摘要:
我们提出了一个实验室芯片上的实验,以准确地测量微波和亚毫米波长的超导微带线的损耗。微带是由NbTiN,这是使用反应磁控溅射沉积,和非晶硅,这是使用等离子体增强化学气相沉积(PECVD)沉积。使用工作在$350\ $ GHz附近的片上法布里-珀罗谐振器(FPR)测量亚毫米波损耗。微波损耗测量使用具有相同的几何形状和制造在同一芯片上的分流半波谐振器。我们在$6\ $ GHz和$\tanδ= 2.1\pm 0.1\times10^{-4}$在$350\ $ GHz的$\tanδ=3.7\pm0.5\times10^{-5}$的单光子能量下测量非晶硅的损耗角正切。这些结果代表了沉积物的非常低的损耗,但是亚毫米波损耗明显高于微波损耗,这不能使用标准的两级系统损耗模型来理解。
英文摘要:
We present a lab-on-chip experiment to accurately measure losses of superconducting microstrip lines at microwave and sub-mm wavelengths. The microstrips are fabricated from NbTiN, which is deposited using reactive magnetron sputtering, and amorphous silicon which is deposited using plasma-enhanced chemical vapor deposition (PECVD). Sub-mm wave losses are measured using on-chip Fabry-P{é}rot resonators (FPR) operating around $350\ $GHz. Microwave losses are measured using shunted half-wave resonators with an identical geometry and fabricated on the same chip. We measure a loss tangent of the amorphous silicon at single-photon energies of $\tanδ=3.7\pm0.5\times10^{-5}$ at $6\ $GHz and $\tanδ= 2.1\pm 0.1\times10^{-4}$ at $350\ $GHz. These results represent very low losses for deposited dielectrics, but the sub-mm wave losses are significantly higher than the microwave losses, which cannot be understood using the standard two-level system loss model.