arXiv 2108.01274physics.med-ph
收藏

用于等剂量调整的体积剂量扩展

Volumetric dose extension for isodose tuning

Lin Ma, Mingli Chen, Xuejun Gu, Weiguo Lu

摘要:

目的:开发一个模型,从两个等剂量面(等面)生成体积剂量分布,并通过等面拖动交互式调整剂量分布。方法:将体积剂量分布建模为两个等值面的解析扩展,扩展变量为到等值面的距离。我们建立了一个3D查找表(LUT)的基础上产生的临床剂量分布。两个LUT表存储临床剂量的体素剂量值的平均值和标准差,并将其划分为与100%等值面、参考等值面和参考剂量水平的距离。交互式调优过程从给定的基本平面开始。用户拖动等值面进行所需的雕刻。我们的方法响应调整剂量。调谐剂量的推导遵循两个步骤。通过查表,使用到两个等值面的距离和参考剂量水平作为键,将剂量从两个用户期望的等值面(例如100%和50%)扩展到整个患者体积。然后,我们微调扩展剂量的校正策略,利用基本计划的信息。结果:我们在术后前列腺计划的共面VMAT剂量上验证了该方法。LUT由27个临床计划的剂量分布填充。我们优化了两个计划,不同的直肠保留一个独立的情况下,模仿剂量调整的过程。直肠保留较少的方案被设置为基本方案。将更节省计划的50%等值面定义为所需等值面输入。通过我们的方法(扩展和校正)输出的剂量与通过优化获得的更节省的计划一致,在伽马(97.2%),DVH和配置文件方面。总剂量重建时间在两秒内。结论:我们开发了一种基于等值面距离的体积剂量重建方法,并将其应用于等值面拖动的交互式调整。

英文摘要:

Purpose: To develop a model to generate volumetric dose distribution from two isodose surfaces (iso-surfaces), and to interactively tune dose distribution by iso-surface dragging. Methods: We model volumetric dose distribution as analytical extension of two iso-surfaces with the extension variables as distances to iso-surfaces. We built a 3D lookup table (LUT) which are generated based on clinical dose distributions. Two LUT tables store the mean and standard deviation of voxel dose values of clinical doses and binned as distance to 100% iso-surface, reference iso-surface and reference dose level. The process of interactive tuning starts from a given base plan. A user drags iso-surface for a desired carving. Our method responds with tuned dose. The derivation of tuned dose follows two steps. Dose is extended from the two user-desired iso-surfaces (eg.100% and 50%) to the whole patient volume by table lookup, using distances to two iso-surfaces and reference dose level as keys. Then we fine tune the extended dose by a correction strategy utilizing the information of base plan. Results: We validated this method on coplanar VMAT doses of post-operative prostate plans. The LUT was populated by dose distributions of 27 clinical plans. We optimized two plans with different rectum sparing for an independent case to mimic the process of dose tuning. The plan with less rectum sparing is set as base plan. The 50% iso-surface of the more-sparing plan is defined as the desired iso-surface input. The dose output by our method (expansion and correction) agrees with the more-sparing plan obtained by optimization, in terms of gamma (97.2%), DVH and profiles. The overall dose reconstruction time is within two seconds. Conclusion: We developed a distance-to-isosurface based volumetric dose reconstruction method, and applied it to interactive tuning with iso-surface dragging.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑