Purpose: To develop a model to generate volumetric dose distribution from two isodose surfaces (iso-surfaces), and to interactively tune dose distribution by iso-surface dragging. Methods: We model volumetric dose distribution as analytical extension of two iso-surfaces with the extension variables as distances to iso-surfaces. We built a 3D lookup table (LUT) which are generated based on clinical dose distributions. Two LUT tables store the mean and standard deviation of voxel dose values of clinical doses and binned as distance to 100% iso-surface, reference iso-surface and reference dose level. The process of interactive tuning starts from a given base plan. A user drags iso-surface for a desired carving. Our method responds with tuned dose. The derivation of tuned dose follows two steps. Dose is extended from the two user-desired iso-surfaces (eg.100% and 50%) to the whole patient volume by table lookup, using distances to two iso-surfaces and reference dose level as keys. Then we fine tune the extended dose by a correction strategy utilizing the information of base plan. Results: We validated this method on coplanar VMAT doses of post-operative prostate plans. The LUT was populated by dose distributions of 27 clinical plans. We optimized two plans with different rectum sparing for an independent case to mimic the process of dose tuning. The plan with less rectum sparing is set as base plan. The 50% iso-surface of the more-sparing plan is defined as the desired iso-surface input. The dose output by our method (expansion and correction) agrees with the more-sparing plan obtained by optimization, in terms of gamma (97.2%), DVH and profiles. The overall dose reconstruction time is within two seconds. Conclusion: We developed a distance-to-isosurface based volumetric dose reconstruction method, and applied it to interactive tuning with iso-surface dragging.
A volumetric Modulated Arc Therapy (VMAT) combined with deep inspiration breath hold (DIBH) technique for adjuvant irradiation for left sided breast cancer
Treatment plan comparison of Linac step and shoot,Tomotherapy, RapidArc, and Proton therapy for prostate cancer using dosimetrical and biological index
本研究的目的是使用各种剂量学指标来确定治疗前列腺癌患者的最佳调强放射治疗模式技术。本研究纳入了10例前列腺癌患者。调强放射治疗计划旨在包括不同的模式,包括直线加速器步进和发射、断层治疗、RapidArc和质子系统。采用剂量学指标,如处方等剂量与靶区体积比(PITV)、适形指数(CI)、均匀性指数(HI)、靶区覆盖指数(TCI)、修正剂量均匀性指数(MHI)、适形数(CN)、关键器官评分指数(COSI)和品质因数(QF),对不同治疗方案进行比较。生物学指标,如广义等效均匀剂量(gEUD),基于肿瘤控制概率(TCP)和正常组织并发症概率(NTCP)也被计算和用于比较治疗计划。RapidArc计划获得了更好的PTV覆盖,其优越的PITV、CI、TCI、MHI和CN值证明了这一点。关于OAR,质子治疗在低剂量体积中表现出更好的直肠和肠道剂量节省,而断层治疗和RapidArc计划在高剂量体积中实现了更好的剂量节省。QF评分在这些计划之间没有显着差异(p=0.701)。RapidArc、Linac和Proton计划中前列腺肿瘤的平均TCP高于断层治疗的平均TCP(分别为98.79%、98.76%和98.75% vs. 98.70%)。关于直肠NTCP,RapidArc显示了最有利的结果(0.09%),而Linac产生了最好的膀胱NTCP(0.08%)。