arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2107.13558astro-ph.IM
收藏

SCUBA-2的十年:在JCMT校准450 $μ$ m和850 $μ$ m连续数据的综合指南

A Decade of SCUBA-2: A Comprehensive Guide to Calibrating 450 $μ$m and 850 $μ$m Continuum Data at the JCMT

Steve Mairs, Jessica T. Dempsey, Graham S. Bell, Harriet Parsons, Malcolm J. Currie, Per Friberg, Xue-Jian Jiang, Alexandra J. Tetarenko, Dan Bintley, Jamie Coo… 展开作者

Steve Mairs, Jessica T. Dempsey, Graham S. Bell, Harriet Parsons, Malcolm J. Currie, Per Friberg, Xue-Jian Jiang, Alexandra J. Tetarenko, Dan Bintley, Jamie Cookson, Shaoliang Li, Mark G. Rawlings, Jan Wouterloot, David Berry, Sarah Graves, Izumi Mizuno, Alexis Ann Acohido, Alyssa Clark, Jeff Cox, Miriam Fuchs, James Hoge, Johnathon Kemp, E'lisa Lee, Callie Matulonis, William Montgomerie, Kevin Silva, Patrice Smith

摘要:

亚毫米波段普通用户测辐射热仪阵列2(SCUBA-2)是詹姆斯·克拉克·麦克斯韦望远镜的连续谱成像仪,可同时工作在450和850~ $μ$ m波段。SCUBA-2于2009- 2011年投入使用,自那时以来,每当仪器使用时,都会对点状标准源进行定期观测。本文将定标器观测样本比以往工作扩大了一个数量级,推导了新的大气消光校正在每个波长处的更新不透明度关系,分析了用于将仪器单位转换为物理通量单位的通量转换因子(FCF)作为日期和观测时间的函数,给出了每个波长的光束轮廓信息,并更新次级校准源通量。在07:00 ~ 17:00 UTC期间,对温度梯度引起的碟形形变最稳定的夜间部分,在450 $μ$ m处测得的总通量不确定度和峰值通量不确定度分别为14%和17%。在850~ $μ$ m处测量,总通量和峰值通量的不确定度分别为6%和7%。本工作中的分析适用于自2011年以来观察到的所有SCUBA-2项目。

英文摘要:

The Submillimetre Common User Bolometer Array 2 (SCUBA-2) is the James Clerk Maxwell Telescope's continuum imager, operating simultaneously at 450 and 850~$μ$m. SCUBA-2 was commissioned in 2009--2011 and since that time, regular observations of point-like standard sources have been performed whenever the instrument is in use. Expanding the calibrator observation sample by an order of magnitude compared to previous work, in this paper we derive updated opacity relations at each wavelength for a new atmospheric-extinction correction, analyze the Flux-Conversion Factors (FCFs) used to convert instrumental units to physical flux units as a function of date and observation time, present information on the beam profiles for each wavelength, and update secondary-calibrator source fluxes. Between 07:00 and 17:00 UTC, the portion of the night that is most stable to temperature gradients that cause dish deformation, the total-flux uncertainty and the peak-flux uncertainty measured at 450~$μ$m are found to be 14\% and 17\%, respectively. Measured at 850~$μ$m, the total-flux and peak-flux uncertainties are 6\%, and 7\%, respectively. The analysis presented in this work is applicable to all SCUBA-2 projects observed since 2011.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑