We propose a feature generator backbone composed of an ensemble of convolutional neuralnetworks (CNNs) to improve the recently emerging Vision Transformer (ViT) models. We tackled the RSNA intracranial hemorrhage classification problem, i.e., identifying various hemorrhage types from computed tomography (CT) slices. We show that by gradually stacking several feature maps extracted using multiple Xception CNNs, we can develop a feature-rich input for the ViT model. Our approach allowed the ViT model to pay attention to relevant features at multiple levels. Moreover, pretraining the n CNNs using various paradigms leads to a diverse feature set and further improves the performance of the proposed n-CNN-ViT. We achieved a test accuracy of 98.04% with a weighted logarithmic loss value of 0.0708. The proposed architecture is modular and scalable in both the number of CNNs used for feature extraction and the size of the ViT.
Intracranial hemorrhage segmentation challenge (INSTANCE 2022) offers a platform for researchers to compare their solutions to segmentation of hemorrhage stroke regions from 3D CTs. In this work, we describe our solution to INSTANCE 2022. We use a 2D segmentation network, SegResNet from MONAI, operating slice-wise without resampling. The final submission is an ensemble of 18 models. Our solution (team name NVAUTO) achieves the top place in terms of Dice metric (0.721), and overall rank 2. It is implemented with Auto3DSeg.
Smooth Attention for Deep Multiple Instance Learning: Application to CT Intracranial Hemorrhage Detection
Northwestern University(西北大学);University of Granada(格拉纳达大学);Research Centre for Information and Communication Technologies (CITIC-UGR)(信息与通信技术研究中心(CITIC-UGR))
Data augmentation can effectively resolve a scarcity of images when training machine-learning algorithms. It can make them more robust to unseen images. We present a lesion conditional Generative Adversarial Network LcGAN to generate synthetic Computed Tomography (CT) images for data augmentation. A lesion conditional image (segmented mask) is an input to both the generator and the discriminator of the LcGAN during training. The trained model generates contextual CT images based on input masks. We quantify the quality of the images by using a fully convolutional network (FCN) score and blurrin…
Capital Medical University(首都医科大学);China National Clinical Research Center for Neurological Diseases(国家神经系统疾病临床医学研究中心);Tencent(腾讯);Shandong Jining Medical College(山东济宁医学院)
Background: To develop an artificial intelligence system that can accurately identify acute non-traumatic intracranial hemorrhage (ICH) etiology based on non-contrast CT (NCCT) scans and investigate whether clinicians can benefit from it in a diagnostic setting. Materials and Methods: The deep learning model was developed with 1868 eligible NCCT scans with non-traumatic ICH collected between January 2011 and April 2018. We tested the model on two independent datasets (TT200 and SD 98) collected after April 2018. The model's diagnostic performance was compared with clinicians's performance. We …
SWDL: Stratum-Wise Difference Learning with Deep Laplacian Pyramid for Semi-Supervised 3D Intracranial Hemorrhage Segmentation
School of Computer Science and Engineering, Southeast University(东南大学计算机科学与工程学院);Research Center for Medical Artificial Intelligence, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院医学人工智能研究中心);Beijing Tiantan Hospital, Capital Medical University(首都医科大学北京天坛医院)
Florida Atlantic University(佛罗里达大西洋大学);University of Technology(理工大学);Babylon Health Directorate(巴比伦卫生局)
Traumatic brain injuries could cause intracranial hemorrhage (ICH). ICH could lead to disability or death if it is not accurately diagnosed and treated in a time-sensitive procedure. The current clinical protocol to diagnose ICH is examining Computerized Tomography (CT) scans by radiologists to detect ICH and localize its regions. However, this process relies heavily on the availability of an experienced radiologist. In this paper, we designed a study protocol to collect a dataset of 82 CT scans of subjects with traumatic brain injury. Later, the ICH regions were manually delineated in each sl…
Automatic intracranial hemorrhage segmentation in 3D non-contrast head CT (NCCT) scans is significant in clinical practice. Existing hemorrhage segmentation methods usually ignores the anisotropic nature of the NCCT, and are evaluated on different in-house datasets with distinct metrics, making it highly challenging to improve segmentation performance and perform objective comparisons among different methods. The INSTANCE 2022 was a grand challenge held in conjunction with the 2022 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI). It is intended t…
St. Michael’s Hospital(圣迈克尔医院);University of Toronto(多伦多大学)
Machine learning (ML) holds great promise in transforming healthcare. While published studies have shown the utility of ML models in interpreting medical imaging examinations, these are often evaluated under laboratory settings. The importance of real world evaluation is best illustrated by case studies that have documented successes and failures in the translation of these models into clinical environments. A key prerequisite for the clinical adoption of these technologies is demonstrating generalizable ML model performance under real world circumstances. The purpose of this study was to demo…
Vision Transformer for Intracranial Hemorrhage Classification in CT Scans Using an Entropy-Aware Fuzzy Integral Strategy for Adaptive Scan-Level Decision Fusion
School of Electrical and Computer Engineering, College of Engineering, University of Tehran(塔里斯坦大学电气与计算机工程学院);Department of Computer Science and Engineering, Sejong University(世宗大学计算机科学与工程系)
Multi-task Learning Approach for Intracranial Hemorrhage Prognosis
Advanced Computing and e-Science Group, Institute of Physics of Cantabria (IFCA), CSIC - UC(先进计算与电子科学组,坎塔布里亚物理研究所(IFCA),CSIC-UC);AI Technology for Life, Department of Computing and Information Sciences, Utrecht University(人工智能技术与生命,计算与信息科学系,乌得勒支大学);Department of Radiology, The Netherlands Cancer Institute(放射科,荷兰癌症研究所);Servicio de Radiología, Hospital Reina Sofía(放射科,雷娜·索菲亚医院);Servicio de Radiología, Hospital Universitario Rey Juan Carlos(放射科,雷昂·卡洛斯大学医院);Departamento de Tecnologías de La Información, Universidad CEU San Pablo(信息技术部,CEU桑帕布洛大学)
We propose Artificial Intelligence Prospective Randomized Observer Blinding Evaluation (AI-PROBE) for quantitative clinical performance evaluation of radiology AI systems within prospective randomized clinical trials. AI-PROBE encompasses a study design and a matching radiology IT infrastructure that randomly blinds radiologists for results provided by AI-based image analysis. To demonstrate the applicability of our evaluation framework, we present a first prospective randomized clinical trial on the effect of Intra-Cranial Hemorrhage (ICH) detection in emergent care head CT on radiology study…
Intracranial hemorrhages (ICHs) are life-threatening brain injures with a relatively high incidence. In this paper, the automatic algorithm for the detection and classification of ICHs, including localization, is present. The set of binary convolutional neural network-based classifiers with a designed cascade-parallel architecture is used. This automatic system may lead to a distinct decrease in the diagnostic process's duration in acute cases. An average Jaccard coefficient of 53.7 % is achieved on the data from the publicly available head CT dataset CQ500.
Sberbank AI Lab(俄罗斯联邦储蓄银行人工智能实验室);New York University(纽约大学)
Segmentation of ischemic stroke and intracranial hemorrhage on computed tomography is essential for investigation and treatment of stroke. In this paper, we modified the U-Net CNN architecture for the stroke identification problem using non-contrast CT. We applied the proposed DL model to historical patient data and also conducted clinical experiments involving ten experienced radiologists. Our model achieved strong results on historical data, and significantly outperformed seven radiologist out of ten, while being on par with the remaining three.