AI总结:

本文构建气管音数据库 HF_Tracheal_V1,并与肺音数据库 HF_Lung_V2 结合,提出基于混合集训练或领域自适应的 CNN-BiGRU 模型,证明其能同时提升肺音与气管音中吸气、呼气及连续附加音检测性能。

摘要:

此前已有许多基于深度学习的计算机化呼吸音分析方法被开发出来。然而,这些研究要么只关注肺音,要么只关注气管音。将肺音分析算法用于气管音以及将气管音分析算法用于肺音的有效性从未被研究过。此外,没有人知道在训练呼吸音分析模型时同时使用肺音和气管音是否有益。在本研究中,我们首先构建了一个气管音数据库 HF_Tracheal_V1,其中包含 10448 段 15 秒气管音录音、21741 个吸气标签、15858 个呼气标签和 6414 个连续附加音(CAS)标签。我们将 HF_Tracheal_V1 与我们此前构建的肺音数据库 HF_Lung_V2 进行组合(混合集)、先后使用(领域自适应)或单独使用,以训练卷积神经网络双向门控循环单元模型,用于肺音和气管音中的吸气、呼气及 CAS 检测。结果表明,仅使用肺音训练的模型在气管音分析中表现不佳,反之亦然。然而,与阳性对照(仅使用肺音训练并用于肺音分析的模型,以及仅使用气管音训练并用于气管音分析的模型)相比,混合集训练或领域自适应改善了以下性能:1)肺音中的吸气和呼气检测;2)气管音中的吸气、呼气和 CAS 检测。特别是,在混合集上训练的模型具有极大的灵活性,可以同时服务于肺音分析和气管音分析两个目的。

英文摘要:

Many deep learning-based computerized respiratory sound analysis methods have previously been developed. However, these studies focus on either lung sound only or tracheal sound only. The effectiveness of using a lung sound analysis algorithm on tracheal sound and vice versa has never been investigated. Furthermore, no one knows whether using lung and tracheal sounds together in training a respiratory sound analysis model is beneficial. In this study, we first constructed a tracheal sound database, HF_Tracheal_V1, containing 10448 15-s tracheal sound recordings, 21741 inhalation labels, 15858 exhalation labels, and 6414 continuous adventitious sound (CAS) labels. HF_Tracheal_V1 and our previously built lung sound database, HF_Lung_V2, were either combined (mixed set), used one after the other (domain adaptation), or used alone to train convolutional neural network bidirectional gate recurrent unit models for inhalation, exhalation, and CAS detection in lung and tracheal sounds. The results revealed that the models trained using lung sound alone performed poorly in tracheal sound analysis and vice versa. However, mixed set training or domain adaptation improved the performance for 1) inhalation and exhalation detection in lung sounds and 2) inhalation, exhalation, and CAS detection in tracheal sounds compared to positive controls (the models trained using lung sound alone and used in lung sound analysis and vice versa). In particular, the model trained on the mixed set had great flexibility to serve two purposes, lung and tracheal sound analyses, at the same time.