We introduce two tractable analytical models to describe dynamic effects at resonant light scattering by subwavelength particles. One of them is based on generalization of the temporal coupled-mode theory, and the other employs the normal mode approach. We show that sharp variations in the envelope of the incident pulse may initiate unusual, counterintuitive dynamics of the scattering associated with interference of modes with fast and slow relaxation. To exhibit the power of the models, we apply them to explain the dynamic light scattering of a square-envelope pulse by an infinite circular cylinder made of $GaP$, when the pulse carrier frequency lies in the vicinity of the destructive interference at the Fano resonances. We observe and explain intensive sharp spikes in scattering cross section just behind the leading and trailing edges of the incident pulse. The latter occurs when the incident pulse is over and is explained by the electromagnetic energy released in the particle at the previous scattering stages. The accuracy of the models is checked against their comparison with results of the direct numerical integration of the complete set of Maxwell's equations and occurs very high. The models' advantages and disadvantages are revealed, and the ways to apply them to other types of dynamic resonant scattering are discussed.
Ultrasensitive THz sensing with high-Q Fano resonances in metasurfaces
高品质因数共振对于设计超灵敏折射率无标记传感器是非常有希望的,因为它允许电磁波和分析物材料之间的强烈相互作用。超材料和等离子体传感由于其谐振结构中电磁场的亚波长限制而引起了人们的广泛关注。然而,在这些系统中激发高品质因数共振一直是一个挑战。我们激发了一个数量级更高的品质因数共振平面太赫兹超材料,我们利用超灵敏传感。具有极窄线宽的低损耗四极和Fano共振使我们能够测量由于周围介质折射率的最小变化而引起的微小光谱偏移。我们用四极子实现了7.75 x 10^3 nm/ RIU的灵敏度水平,用Fano共振实现了5.7 x 10^4 nm/ RIU的灵敏度水平,这可以通过使用更薄的衬底进一步增强。这些发现将有助于设计超灵敏的实时化学和生物分子传感器的指纹区域的太赫兹制度。
Performance improvement of refractometric sensors through hybrid plasmonic-Fano resonances
在本文中,我们提出了一个等离子体折射传感器,工作在正常的入射,允许其集成在光纤尖端。该传感器的材料和几何形状利用了由折射率的高对比度亚波长介质光栅给出的大散射截面。由于表面等离子体共振和光栅响应之间的干涉,我们的设计产生了混合等离子体-Fano共振。我们优化传感器的品质函数,结合了质量参数的共振和等离子体传播的相互作用体积的场增强。我们的器件显示出高灵敏度(1000 nm/RIU)和高品质因数(775 RIU $^{-1}$)。性能下降是可以忽略不计的,通过一个宽的动态范围高达0.7 RIU。与类似的等离子体传感器相比,这些定量参数表现出色。