质点模型在非共振动态原子力显微镜中的有效性
Validity of point-mass model in off-resonance dynamic atomic force microscopy
摘要:
纳米尺度物质粘弹性的定量测量是纳米技术研究的重要目标,随着动态原子力显微镜的出现,纳米尺度物质粘弹性的定量测量有了长足的进展.悬臂梁作为AFM测量中的力传感器,其流体力学特性在纳米尺度粘弹性的定量估计中起着关键作用。质点模型,其中原子力显微镜悬臂近似为一个质点与无质量弹簧被广泛用于动态原子力显微镜分析和其有效性,特别是在液体环境中,是有争议的。有人建议,悬臂梁必须被视为一个连续的矩形梁,以获得准确的估计纳米尺度的材料的粘弹性,它是探测。在这里,我们推导出方程,其中涉及的刚度和阻尼系数的材料进行调查的测量参数,通过近似悬臂作为一个质点,并考虑到完整的几何细节。这些方程都是由尖激励和基激励的悬臂梁导出的。我们对单个蛋白质分子进行了非共振动态原子力光谱研究,以考察广泛使用的质点模型的有效性。我们进行了测量与AFM配备了不同的悬臂梁激励方法以及检测方案来测量悬臂梁的响应。使用连续束模型和质点模型分析数据。我们发现,这两个模型产生相同的结果时,实验是在真正的非共振制度与小振幅和悬臂刚度是远远高于相互作用的刚度。我们的研究结果表明,一个简单的质点近似为基础的模型是足以描述的动态,提供照顾,同时进行实验,使这些模型中使用的近似是有效的。
英文摘要:
The quantitative measurement of viscoelasticity of nano-scaleentities is an important goal of nanotechnology research and there is considerable progress with advent of dynamic Atomic Force Microscopy. The hydrodynamics of cantilever, the force sensor in AFM measurements, plays a pivotal role in quantitative estimates of nano-scale viscoelasticity. The point-mass model,wherein the AFM cantilever is approximated as a point mass with mass-less spring is widely used in dynamic AFM analysis and its validity, particularly in liquid environments, is debated. It is suggested that the cantilever must be treated as a continuous rectangular beam to obtain accurate estimates of nano-scale viscoelasticity of materials it is probing. Here, we derived equations, which relate stiffness and damping coefficient of the material under investigation to measured parameters, by approximating cantilever as a point mass and also considering the full geometric details. These equations are derived for both tip-excited as well as base excited cantilevers. We have performed off-resonance dynamic atomic force spectroscopy on a single protein molecule to investigate the validity of widely used point-mass model. We performed measurements with AFMs equipped with different cantilever excitation methods as well as detection schemes to measure cantilever response. The data was analyzed using both, continuous-beam model and the point-mass model. We found that both models yield same results when the experiments are performed in truly off-resonance regime with small amplitudes and the cantilever stiffness is much higher than the interaction stiffness. Our findings suggest that a simple point-mass approximation based model is adequate to describe the dynamics, provided care is taken while performing experiments so that the approximations used in these models are valid.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。