J-PARC μ子$g-2$ / EDM实验低功率分配系统的研制
A fabrication of low power distribution system for muon $g-2$/EDM experiment at J-PARC
摘要:
J-PARC μ子$g - 2$ /EDM实验旨在测量μ子磁矩异常$a_μ = (g -2) / 2 ~ $和μ子电偶极矩(EDM)$d_μ$。$a_μ$的目标灵敏度是$450 \times 10^{-9}$的统计不确定度,而$d_μ$的目标灵敏度是$1.5 \times 10^{-21}$ $e \cdot \rm{cm}$。读出电子设备需要DC到DC转换器,以在特定环境中提供1.5 V和3.3 V电压。为了捕获来自μ子的正电子衰变,探测器组件被放置在真空中施加3 T磁场的μ子存储区域中。转换器的额外磁场应小于30 $μ$ T,以达到上述$a_μ$的灵敏度。此外,转换器产生的电场必须小至1 V/m,才能达到$d_μ$的目标灵敏度。为此,我们开发了一个降压转换器。讨论了J-PARC μ子$g - 2$ /EDM实验用DC/DC转换器的研制过程和性能。
英文摘要:
The J-PARC muon $g - 2$/EDM experiment aims to measure the muon magnetic moment anomaly $a_μ = (g -2) / 2 ~ $ and the muon electric dipole moment (EDM) $d_μ$. The target sensitivity for $a_μ$ is a statistical uncertainty of $450 \times 10^{-9}$, and for $d_μ$ it is $1.5 \times 10^{-21}$ $e \cdot \rm{cm}$. The readout electronics require a DC to DC converter to provide 1.5 V and 3.3 V electric voltage within a specific environment. To capture the positron decay from the muon, the detector components are placed in the muon storage area where a 3 T magnetic field is applied in a vacuum. The extra magnetic field from the converter should be less than 30 $μ$T to reach the aforementioned sensitivity on $a_μ$. In addition, the electric field produced by the converter has to be as small as 1 V/m to also reach the target sensitivity on $d_μ$. For this purpose, we develop a step-down converter. We discuss the development process and the performance of our DC to DC converter for the J-PARC muon $g - 2$/EDM experiment.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。