arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2103.12095cs.LGcs.AI
收藏

我适合这种体力活动吗?惯性传感器物理条件的神经嵌入

Am I fit for this physical activity? Neural embedding of physical conditioning from inertial sensors

Universidade Federal de Minas Gerais(米纳斯吉拉斯联邦大学)

Davi Pedrosa de Aguiar, Fabricio Murai

摘要:

惯性测量单元(IMU)传感器存在于智能手机和健身手表等日常设备中。因此,利用这些数据的一系列健康相关研究和应用一直在增长,但很少有人关注在进行体力活动时从IMU数据预测个人的心率(HR)。这可能吗如果是这样的话,例如,这可以用来设计个性化的有氧运动。在这项工作中,我们证明了使用递归神经网络从IMU数据中获得准确的HR预测是可行的,前提是只能访问来自短期的先前执行的活动的HR和IMU数据。我们提出了一种新的方法来初始化RNN的隐藏状态向量,使用一个专门的网络,试图提取一个主题的物理条件(PCE)的嵌入。我们表明,在训练阶段使用一个训练器来帮助模型学习两个PCE是否属于同一个人,进一步降低了预测误差。我们评估了所提出的模型时,预测23名受试者进行各种身体活动的公共数据集(PAMAP 2,PPG-DaLiA)的IMU数据的HR。为了进行比较,我们使用专门为此任务提出的唯一模型作为基线,并使用一种适用于人类活动识别(HAR)的最先进模型,这是一项密切相关的任务。我们的方法PCE-LSTM的平均绝对误差降低了10%以上。我们的经验表明,这种错误的减少部分是由于使用的PCE。最后,我们使用两个数据集(PPG-DaLiA,WESAD)来证明,当光电体积描记(PPG)传感器可用时,PCE-LSTM也可以成功应用,比最先进的深度学习基线性能高出30%以上。

英文摘要:

Inertial Measurement Unit (IMU) sensors are present in everyday devices such as smartphones and fitness watches. As a result, the array of health-related research and applications that tap onto this data has been growing, but little attention has been devoted to the prediction of an individual's heart rate (HR) from IMU data, when undergoing a physical activity. Would that be even possible? If so, this could be used to design personalized sets of aerobic exercises, for instance. In this work, we show that it is viable to obtain accurate HR predictions from IMU data using Recurrent Neural Networks, provided only access to HR and IMU data from a short-lived, previously executed activity. We propose a novel method for initializing an RNN's hidden state vectors, using a specialized network that attempts to extract an embedding of the physical conditioning (PCE) of a subject. We show that using a discriminator in the training phase to help the model learn whether two PCEs belong to the same individual further reduces the prediction error. We evaluate the proposed model when predicting the HR of 23 subjects performing a variety of physical activities from IMU data available in public datasets (PAMAP2, PPG-DaLiA). For comparison, we use as baselines the only model specifically proposed for this task and an adapted state-of-the-art model for Human Activity Recognition (HAR), a closely related task. Our method, PCE-LSTM, yields over 10% lower mean absolute error. We demonstrate empirically that this error reduction is in part due to the use of the PCE. Last, we use the two datasets (PPG-DaLiA, WESAD) to show that PCE-LSTM can also be successfully applied when photoplethysmography (PPG) sensors are available, outperforming the state-of-the-art deep learning baselines by more than 30%.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑