Numerical qualification of an eco-friendly alternative gas mixture for avalanche mode operation of Resistive Plate Chambers is the soul of this work. To identify the gas mixture, a numerical model developed elsewhere by the authors has been first established by comparing the simulated figure of merits (efficiency and streamer probability) with the experimental data for the gas mixture used in INO-ICAL. Then it has been used to simulate the same properties of a gas mixture based on argon, carbon di-oxide and nitrogen, identified as potential replacement by studying its different properties. Efficacy of this eco-friendly gas mixture has been studied by comparing the simulated result with the standard gas mixture used in INO-ICAL as well as with experimental data of other eco-friendly hydrofluorocarbon (HFO1234ze) based potential replacements. To increase the efficacy of the proposed gas mixture, studies of the traditional way (addition of a little amount of SF$_6$) and an alternative approach (exploring the option of high-end electronics) were carried out.
Sub-relativistic magnetic monopoles are predicted from the GUT era by theory. To date there have been no confirmed observations of such exotic particles. The Iron CALorimeter (ICAL) at India-based Neutrino Observatory (INO) aims to measure the neutrino oscillation parameters precisely. As it is a tracking detector there is also the possibility of detecting magnetic monopoles in the sub-relativistic region. Using ICAL the magnetic monopole event is characterised by the large time intervals of upto 30 microsec between the signals in successive layers of the active detectors. The aim of this stud…
We present the reach of the proposed INO-ICAL in measuring the atmospheric-neutrino-oscillation parameters $θ_{23}$ and $Δm^2_{32}$ using full event-by-event reconstruction for the first time. We also study the fluctuations in the data and their effect on the precision measurements and mass-hierarchy analysis for a five-year exposure of the 50 kton ICAL detector. We find a mean resolution of $Δχ^2 \approx 2.9$, which rules out the wrong mass hierarchy of the neutrinos with a significance of approximately $1.7σ$. These results are similar to those to presented earlier studies that approximated …
India-based Neutrino Observatory (INO) is a planned neutrino experiment to be build up in southern part of India.The INO observatory will host a 51 kton Iron Calorimeter (ICAL) detector to detect atmospheric neutrinos. Resistive Plate Chamber (RPC) has been chosen as the active detector element for the ICAL experiment. The ICAL experiment will consist of about 28,000 RPC's of dimension $2~m\times 2~m$, divided into three modules. The experiment is planned to take data at least for 20 years from its start date. Due to the large number of RPC needed for ICAL experiment and the long lifetime of t…
The India-based Neutrino Observatory (INO) collaboration has chosen glass Resistive Plate Chambers (RPCs) as the active detector elements for the Iron Calorimeter (ICAL) experiment. In the present work, we study the electrical properties such as bulk resistivity and relative permittivity of the glasses from two different manufacturers and compared the performances of RPCs built using these glasses. We conclude that the glass electrodes with larger bulk resistivy and permittivity are better suited for manufacturing RPCs for the ICAL experiment, as these detectors could be operated at lower bias…
Glass based Resistive Plate Chambers (RPCs) are going to be used as an active element in the Iron Calorimeter (ICAL) experiment at the India based Neutrino Observatory (INO), which is being constructed to study atmospheric neutrinos. Though the RPC detector operational parameters are more or less finalized, the readout electronics is being developed using various technologies. The ICAL experiment will consist of about 29,000 RPC detectors of 2 m $\times$ 2 m in size with each detector having 64 readout channels both in the X and Y directions. The present study focusses on multi-channel electro…
The Resistive Plate Chambers (RPCs) are going to be used as the active detectors in the India-based Neutrino Observatory (INO)-Iron Calorimeter (ICAL) experiment for the detection and study of atmospheric neutrinos. In this paper, an extensive study of structural and electrical properties for different kind of bakelite RPC electrodes is presented. RPCs fabricated from these electrodes are tested for their detector efficiency and noise rate. The study concludes with the variation of efficiency, leakage current and counting rate over the period of operation with different gas compositions and op…
The primary physics signal events in the ICAL at INO are the $ν_μ$ charged current (CC) interactions with a well defined muon track. Apart from these events, ICAL can also detect other types of neutrino interactions, i.e. the electron neutrino charged current interactions and the neutral current events. It is possible to have a dataset containing mostly $ν_e$CC events, by imposing appropriate selection cuts on the events. The $ν_μ$ CC and the neutral current events form the background to these events. This study uses the Monte Carlo generated neutrino events, to design the necessary selection …
We report on a detailed simulation study of the hadron energy resolution as a function of the thickness of the absorber plates for the proposed Iron Calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO). We compare the hadron resolutions obtained with absorber thicknesses in the range 1.5--8 cm for neutrino interactions in the energy range 2--15 GeV, which is relevant to hadron production in atmospheric neutrino interactions. We find that at lower energies, the thickness dependence of energy resolution is steeper than at higher energies, however there is a thickness-indepen…
The proposed India-based Neutrino Observatory will host a 50 kton magnetized iron calorimeter (ICAL) with resistive plate chambers as its active detector element. Its primary focus is to study charged-current interactions of atmospheric muon neutrinos via the reconstruction of muons in the detector. We present the first study of the energy and direction reconstruction of the final state lepton and hadrons produced in charged current interactions of atmospheric electron neutrinos at ICAL and the sensitivity of these events to neutrino oscillation parameters $θ_{23}$ and $Δm_{32}^2$. However, th…
The proposed Iron Calorimeter (ICAL) detector at Indian Neutrino Observatory(INO) will be a large (50 kt) magnetized detector located 1270 m underground at Bodi West Hills in Tamilnadu. ICAL is capable of identifying the charge of the particles. In this paper its potential for the measurement of the muon charge ratio is explored by means of a detailed simulation-based study, first using the CORSIKA code and then comparing it with an analytical model (the "pika" model). The estimated muon charge ratio is in agreement with the existing experimental observations, its measure can be extended by IN…
The Iron Calorimeter (ICAL) detector at the proposed India-based Neutrino Observatory (INO) aims to detect atmospheric neutrinos and antineutrinos separately in the multi-GeV range of energies and over a wide range of baselines. By utilizing its charge identification capability, ICAL can efficiently distinguish $μ^-$ and $μ^+$ events. Atmospheric neutrinos passing long distances through Earth can be detected at ICAL with good resolution in energy and direction, which enables ICAL to see the density-dependent matter oscillations experienced by upward-going neutrinos in the multi-GeV range of en…
The India-based Neutrino Observatory (INO) collaboration is planning to build a massive 50kton magnetised Iron Calorimeter (ICAL) detector, to study atmospheric neutrinos and to make precision measurements of the parameters related to neutrino oscillations. Glass Resistive Plate Chambers (RPCs) of about 2m X 2m in size are going to be used as active elements for the ICAL detector. We have fabricated a large number of glass RPC prototypes of 1m X 1m in size and have studied their performance and long term stability. In the process, we have developed and produced a number of materials and compon…
We perform a detailed analysis for the prospects of detecting active-sterile oscillations involving a light sterile neutrino, over a large $Δm^2_{41}$ range of $10^{-5}$ eV$^2$ to $10^2$ eV$^2$, using 10 years of atmospheric neutrino data expected from the proposed 50 kt magnetized ICAL detector at the INO. This detector can observe the atmospheric $ν_μ$ and $\barν_μ$ separately over a wide range of energies and baselines, making it sensitive to the magnitude and sign of $Δm^2_{41}$ over a large range. If there is no light sterile neutrino, ICAL can place competitive upper limit on $|U_{μ4}|^2…
The recently approved India-based Neutrino Observatory will use the world's largest magnet to study atmospheric muon neutrinos. The 50 kiloton Iron Calorimeter consists of iron alternating with single-gap resistive plate chambers. A uniform magnetic field of $\sim$1.5 T is produced in the iron using toroidal-shaped copper coils. Muon neutrinos interact with the iron target to produce charged muons, which are detected by the resistive plate chambers, and tracked using orthogonal pick up strips. Timing information for each layer is used to discriminate between upward and downward traveling muons…
India-based Neutrino Observatory (INO) is a multi-institutional facility, planned to be built up in South India. The INO facility will host a 51 kton magnetized Iron CALorimeter (ICAL) detector to study atmospheric muon neutrinos. Iron plates have been chosen as the target material whereas Resistive Plate Chambers (RPCs) have been chosen as the active detector element for the ICAL experiment. Due to the large number of RPCs needed ($\sim$ 28,000 of $2~m \times 2~m$ in size) for ICAL experiment and for the long lifetime of the experiment, it is necessary to perform a detailed $R\&D$ such that e…
We report on the simulation studies on the possibility of dark matter particle (DMP) decaying into leptonic modes. While not much is known about the properties of dark matter particles except through their gravitational effect, it has been recently conjectured that the so called "anomalous Kolar Events" observed some decades ago may be due to the decay of unstable dark matter particles (M.V.N. Murthy and G.Rajasekaran, Pramana, {\bf 82}, 609 (2014)). The aim of this study is to see if this conjecture can be verified at the proposed Iron Calorimeter (ICAL) detector at INO. We study the possible…
The possibility of Lorentz Invariance Violation (LIV) may appear in unified theories, such as string theory, which allow the existence of a new space-time structure at the Planck scale ($M_p \sim 10^{19}$ GeV). This effect can be observed at low energies with a strength of $\sim 1/M_p$ using the perturbative approach. In the minimal Standard Model extension (SME) framework, the neutrino mass-induced flavor oscillation gets modified in the presence of LIV. The Iron Calorimeter (ICAL) detector at the proposed India-based Neutrino Observatory (INO) offers a unique window to probe these LIV parame…
The iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) will be used to measure neutrino mass hierarchy. The magnet in the ICAL detector will be used to distinguish the {μ^-} and {μ^+} events induced by {ν_μ} and {\bar{ν_μ}}, respectively. Due to the importance of the magnet in ICAL, an electromagnetic simulation has been carried out to study the B-field distribution in iron using various designs. The simulation shows better uniformity in the portion of the iron layer between the coils, which is bounded by regions which have lesser field strength as we move to the pe…
The proposed ICAL experiment at INO aims to identify the neutrino mass hierarchy from observations of atmospheric neutrinos, and help improve the precision on the atmospheric neutrino mixing parameters. While the design of ICAL is primarily optimized to measure muon momentum, it is also capable of measuring the hadron energy in each event. Although the hadron energy is measured with relatively lower resolution, it nevertheless contains crucial information on the event, which may be extracted when taken concomitant with the muon data. We demonstrate that by adding the hadron energy information …
The proposed ICAL detector at INO is a large sized underground magnetized iron detector. ICAL is designed to reconstruct muon momentum using magnetic spectrometers. Energy measurement using magnets fail for muons in TeV range, since the angular deflection of the muon in the magnetic field is negligible and the muon tracks become nearly straight. A new technique for measuring the energy of muons in the TeV range is used by the CCFR neutrino detector, known as the Pair-Meter technique. This technique estimates muon energy from measurements of the energy deposited by the muon in many layers of an…
Studies on Response Uniformity of RPC and Exploring Oscillation Dip and Valley, Non-Standard Interactions, and Earth's Core using Atmospheric Neutrinos at ICAL-INO detector
The neutral current non-standard interactions (NSI's) of neutrino with matter fermions while propagating through long distances inside the Earth matter can give rise to the extra matter potentials apart from the standard MSW potential due to the $W$-mediated interactions in matter. In this paper, we explore the impact of flavor violating neutral current NSI parameter $\varepsilon_{μτ}$ in the oscillation of atmospheric neutrino and antineutrino using the 50 kt magnetized ICAL detector at INO. We find that due to non-zero $\varepsilon_{μτ}$, $ν_μ\rightarrowν_μ$ and $\barν_μ\rightarrow\barν_μ$ t…
The proposed 50 kt Iron Calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) aims to detect atmospheric muon neutrinos and antineutrinos separately in the multi-GeV range of energies and over a wide range of path lengths. While passing through the Earth, the upward-going neutrinos experience a density-dependent matter effect, which can be utilized to extract information about the internal structure of Earth. Since the Earth's matter effect modifies the neutrino oscillation patterns differently for neutrinos and antineutrinos, the capability of ICAL to distinguish $μ^-$ and…
Flavor-dependent long-range leptonic forces mediated by the ultra-light and neutral bosons associated with gauged $L_e-L_μ$ or $L_e-L_τ$ symmetry constitute a minimal extension of the Standard Model. In presence of these new anomaly free abelian symmetries, the SM remains invariant and renormalizable, and can lead to interesting phenomenological consequences. For an example, the electrons inside the Sun can generate a flavor-dependent long-range potential at the Earth surface, which can enhance $ν_μ$ and $\barν_μ$ survival probabilities over a wide range of energies and baselines in atmospheri…
Impact of errors in the magnetic field measurement on the precision determination of neutrino oscillation parameters at the proposed ICAL detector at INO
The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The primary focus of this experiment is to explore the Earth matter effects by observing the energy and zenith angle dependence of the atmospheric neutrinos in the multi-GeV range. This study will be crucial to address some of the outstanding issues in neutrino oscillation physics, including the fundamental issue of neutrino mass hierarchy. In this document, we pre…
The Resistive Plate Chamber is a widely used detector in high energy physics. The operating potential of this chamber is determined by the optimisation of the efficiency and noise rate of the device. This optimisation is based on the assumption that the performance of the device over the whole surface area is uniform. The INO-ICAL experiment is going to use $\sim$ 30000 RPC of size $\sim$2\,m$\times$2\,m. All the RPC will have to pass a minimum quality assurance criteria, but may not be able to maintain a good uniformity over the whole surface area, particularly for the whole running period of…
The India-based Neutrino Observatory (INO) is a project aimed at building a large underground laboratory to explore the Earth's mater effects on the atmospheric neutrinos in multi-GeV range. INO will host a 50 kton magnetized iron calorimeter detector (ICAL) in which Resistive Plate Chambers(RPCs) will be the active detector elements. In ICAL, 28,800 glass RPCs of 2 m $\times$ 2 m size will be operated in the avalanche mode. A small variation in the compositions of ionizing gaseous medium in the RPC affects its performance. Study of the charge distribution of the RPC at different gas compositi…
The proposed 50 \,kton\, INO-ICAL experiment is an upcoming underground high energy physics experiment planned to be commissioned at Bodi hills near Theni, India ($9^{\circ}57'N$, $77^{\circ}16'E$) to study various properties of neutrino oscillations using atmospheric neutrinos produced by extensive air shower phenomenon. The resistive plate chamber has been chosen as the active detector element for the proposed INO-ICAL. An experimental setup consisting a stack of 12 layers of glass resistive plate chambers each with a size of $\sim$2\,m$\times$2\,m has been built at IICHEP, Madurai to study …
The 50 \,kton\, INO-ICAL is a proposed underground high energy physics experiment at Theni, India ($9^{\circ}57'N$, $77^{\circ}16'E$) to study the neutrino oscillation parameters using atmospheric neutrinos. The Resistive Plate Chamber (RPC) has been chosen as the active detector element for the ICAL detector. An experimental setup consisting of 12 layers of glass RPCs of size 2\,m\,$\times$\,2\,m has been built at IICHEP, Madurai to study the long term stability and performance of RPCs which are produced on a large scale in Indian industry. In this paper, the studies on the performance of RPC…
A detailed numerical simulation has been performed to investigate the timing properties of a standard RPC geometry in order to optimize its application in INO-ICAL experiment designed for studying atmospheric neutrinos. The timing information provided by the RPC is an important observable in the experiment to determine the direction of the neutrinos. Effects of various operating conditions and design components on the RPC timing response, mainly the average signal arrival time and the time resolution have been studied in this context. The dependence of the detector efficiency on the same param…
India-based Neutrino Observatory (INO) facility is going to have a 50 kton magnetized Iron CALorimeter (ICAL) detector for precision measurements of neutrino oscillations using atmospheric neutrinos. The proposed ICAL detector will be a stack of magnetized iron plates (acting as target material) interleaved with glass Resistive Plate Chambers (RPCs) as the active detector elements. An RPC is a gaseous detector made up of two parallel electrode plates having high bulk resistivity like that of float glass and bakelite. For the ICAL detector, glass is preferred over bakelite as it does not need a…
The India-based Neutrino Observatory Project (INO) is a proposed underground high energy physics experiment at Theni, India to study the neutrino oscillation parameters using atmospheric neutrinos. The 50 kton magnetised INO-ICAL detector will require approximately 30,000 of 2m$\times$2m Resistive Plate Chambers (RPC) as sensitive detectors and proposed to operate for about 20 years. For success of the experiment, each of the RPCs has to function without showing any significant aging during the period of operation. Hence, various tests including a proper leak test are performed during and afte…
Several high energy physics and neutrino physics experiments worldwide require large-size RPCs to cover wide acceptances. The muon tracking systems in the Iron calorimeter (ICAL) in the INO experiment, India and the near detector in DUNE at Fermilab are two such examples. A (240 cm $\times$ 120 cm $\times$ 0.2 cm) bakelite RPC has been built and tested at Variable Energy Cyclotron Centre, Kolkata, using indigenous materials procured from the local market. No additional lubricant, like oil has been used on the electrode surfaces for smoothening. The chamber is in operation for $>$ 365 days. We …