Alkali-metal atomic magnetometers suffer from heading errors in geomagnetic fields as the measured magnetic field depends on the orientation of the sensor with respect to the field. In addition to the nonlinear Zeeman splitting, the difference between Zeeman resonances in the two hyperfine ground states can also generate heading errors depending on initial spin polarization. We examine heading errors in an all-optical scalar magnetometer that uses free precession of polarized $^{87}\text{Rb}$ atoms by varying the direction and magnitude of the magnetic field at different spin polarization regimes. In the high polarization limit where the lower hyperfine ground state $F = 1$ is almost depopulated, we show that heading errors can be corrected with an analytical expression, reducing the errors by two orders of magnitude in Earth's field. We also verify the linearity of the measured Zeeman precession frequency with the magnetic field. With lower spin polarization, we find that the splitting of the Zeeman resonances for the two hyperfine states causes beating in the precession signals and nonlinearity of the measured precession frequency with the magnetic field. We correct for the frequency shifts by using the unique probe geometry where two orthogonal probe beams measure opposite relative phases between the two hyperfine states during the spin precession.
The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in-phase with the precessing magnetization. In an earth-range field, a multi-component asymmetric magnetic-resonance line with ? 60 Hz width collapses into …
When optically pumped magnetometers are aimed for the use in Earth's magnetic field, the orientation of the sensor to the field direction is of special importance to achieve accurate measurement result. Measurement errors and inaccuracies related to the heading of the sensor can be an even more severe problem in the case of special operational configurations, such as for example the use of strong off-resonant pumping. We systematically study the main contributions to the heading error in systems that promise high magnetic field resolutions at Earth's magnetic field strengths, namely the non-li…
We experimentally investigate the influence of the orientation of optically pumped magnetometers in Earth's magnetic field. We focus our analysis to an operational mode that promises femtotesla field resolu-tions at such field strengths. For this so-called light-shift dispersed Mz(LSD-Mz) regime, we focus on the key parameters defining its performance. That are the reconstructed Larmor frequency, the transfer function between output signal and magnetic field amplitude as well as the shot noise limited field resolution. We demonstrate that due to the use of two well balanced laser beams for opt…
Atomic magnetometry was performed at Earth's magnetic field over a free-space distance of ten meters. Two laser beams aimed at a distant alkali-vapor cell excited and detected the $^{87}$Rb magnetic resonance, allowing the magnetic field within the cell to be interrogated remotely. Operated as a driven oscillator, the magnetometer measured the geomagnetic field with \lessgtrsim{\lesssim}3.5\,pT precision in a $\sim$2\,s data acquisition; this precision was likely limited by ambient field fluctuations. The sensor was also operated in self-oscillating mode with a 5.3\,pT/$\sqrt{\textrm{Hz}}$ noi…
We present a portable optically pumped magnetometer instrument for ultra-sensitive measurements within the Earth's magnetic field. The central part of the system is a sensor head operating a MEMS-based Cs vapor cell in the light-shift dispersed Mz mode. It is connected to a compact, battery-driven electronics module by a flexible cable. We briefly review the working principles of the device and detail on the realization of both, sensor head and electronics. We show shielded and unshielded measurements within a static magnetic field amplitude of 50 uT demonstrating a noise level of the sensor s…
An Accurate Vector Magnetometer via Zeeman Rabi Oscillations
JILA, National Institute of Standards and Technology and University of Colorado(美国国家标准与技术研究院与科罗拉多大学JILA联合研究所);Department of Physics, University of Colorado(科罗拉多大学物理系);ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology(巴塞罗那科学技术研究所光子科学研究所);Paul M. Rady Department of Mechanical Engineering, University of Colorado(科罗拉多大学保罗·M·雷迪机械工程系);FieldLine Medical(FieldLine医疗公司)
The Bell-Bloom-type optically-pumped FID Rubidium atomic magnetometer with a multi-passing probe beam and two counter-propagating pump beams
State Key Laboratory of Quantum Optics Technologies and Devices, and Institute of Optoelectronics, Shanxi University(山西大学量子光学器件与量子光学技术国家重点实验室及光电研究所);School of Physics and Electronic Engineering, Shanxi University(山西大学物理电子工程学院);Collaborative Innovation Center of Extreme Optics, Shanxi University(山西大学极端光学协同创新中心)
Alkali-metal-vapor magnetometers, using coherent precession of polarized atomic spins for magnetic field measurement, have become one of the most sensitive magnetic field detectors. Their application areas range from practical uses such as detections of NMR signals to fundamental physics research such as searches for permanent electric dipole moments. One of the main noise sources of atomic magnetometers comes from the light shift that depends on the frequency of the pump laser. In this work, we theoretically study the light shift, taking into account the relaxation due to the optical pumping …
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating…
Portable Single-Beam Atomic Total-Field Magnetometer for Stand-off Magnetic Sensing
OAQ Co. Ltd.(OAQ有限公司);Department of Physics, Korea Advanced Institute of Science and Technology(韩国科学技术院物理系);Graduate School of Data Science, Pusan National University(釜山国立大学数据科学研究生院)
Phase projection errors in rf-driven optically pumped magnetometers
Institute of Physics Belgrade, University of Belgrade(贝尔格莱德物理研究所,贝尔格莱德大学);Physics Department, University of Fribourg(弗里堡大学物理系);Leibniz Institute of Photonic Technology(莱布尼茨光子技术研究所)