Dermo-DOCTOR:使用具有端到端双编码器的深度卷积神经网络进行并发皮肤病变检测和识别的框架

Dermo-DOCTOR: A framework for concurrent skin lesion detection and recognition using a deep convolutional neural network with end-to-end dual encoders

Khulna University of Engineering & Technology(库尔纳工程技术大学)

Md. Kamrul Hasan, Shidhartho Roy, Chayan Mondal, Md. Ashraful Alam, Md. Toufick E Elahi, Aishwariya Dutta, S. M. Taslim Uddin Raju, Md. Tasnim Jawad, Mohiuddin Ahmad

摘要:

用于同时检测和识别的自动皮肤病变分析对于类间同质性和类内异质性仍然具有挑战性,导致具有有限数据集的单卷积神经网络(CNN)的低通用能力。本文提出了一个端到端的基于深度CNN的框架,用于同时检测和识别皮肤病变,名为Dermo-DOCTOR,由两个编码器组成。来自两个编码器的特征图是按通道融合的,称为融合特征图(FFM)。FFM用于检测子网络中的解码,将两个编码器的输出的每一级与对应的解码器层连接,以检索由于编码器中的池化而丢失的空间信息。对于识别子网络,利用两个编码器和FFM的特征图,将三个完全连接的层的输出聚合以获得最终的病变类。我们利用两个公开的基准数据集(如ISIC-2016和ISIC-2017)对拟议的Dermo-Doctor进行训练和评估。对于ISIC-2016和ISIC-2017测试数据集,实现的分割结果分别显示出85.0%和80.0%的平均交集。所提出的Dermo-DOCTOR还证明了在病变识别方面值得称赞的成功,为这两个数据集分别提供了0.98和0.91的受试者工作特征曲线下的面积。实验结果表明,建议Dermo-DOCTOR优于文献中提到的替代方法,皮肤病变检测和识别。由于Dermo-DOCTOR在两个不同的测试数据集上提供了更好的结果,即使训练数据有限,它也可以成为皮肤科医生的吉祥计算机辅助工具。

英文摘要:

Automated skin lesion analysis for simultaneous detection and recognition is still challenging for inter-class homogeneity and intra-class heterogeneity, leading to low generic capability of a Single Convolutional Neural Network (CNN) with limited datasets. This article proposes an end-to-end deep CNN-based framework for simultaneous detection and recognition of the skin lesions, named Dermo-DOCTOR, consisting of two encoders. The feature maps from two encoders are fused channel-wise, called Fused Feature Map (FFM). The FFM is utilized for decoding in the detection sub-network, concatenating each stage of two encoders' outputs with corresponding decoder layers to retrieve the lost spatial information due to pooling in the encoders. For the recognition sub-network, the outputs of three fully connected layers, utilizing feature maps of two encoders and FFM, are aggregated to obtain a final lesion class. We train and evaluate the proposed Dermo-Doctor utilizing two publicly available benchmark datasets, such as ISIC-2016 and ISIC-2017. The achieved segmentation results exhibit mean intersection over unions of 85.0 % and 80.0 % respectively for ISIC-2016 and ISIC-2017 test datasets. The proposed Dermo-DOCTOR also demonstrates praiseworthy success in lesion recognition, providing the areas under the receiver operating characteristic curves of 0.98 and 0.91 respectively for those two datasets. The experimental results show that the proposed Dermo-DOCTOR outperforms the alternative methods mentioned in the literature, designed for skin lesion detection and recognition. As the Dermo-DOCTOR provides better-results on two different test datasets, even with limited training data, it can be an auspicious computer-aided assistive tool for dermatologists.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑