arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2101.11252eess.IV
收藏

基于自适应三U网的三维超声图像颈总动脉和颈内动脉分割

Segmentation of common and internal carotid arteries from 3D ultrasound images using adaptive triple U-Net

Mingjie Jiang, Yuan Zhao, Bernard Chiu

摘要:

目标:血管壁容积(VWV)和局部血管壁厚度(VWT)从3D超声(US)颈动脉图像测量是敏感的抗动脉粥样硬化药物/饮食治疗的效果。VWV和VWT测量需要颈总动脉和颈内动脉(CCA和ICA)的管腔-内膜(LIB)和中膜-外膜边界(MAB)。然而,大多数现有的分割技术只能自动化CCA分割。需要能够从CCA和ICA分割MAB和LIB的方法来加速VWV和VWT定量。研究方法:CCA和ICA的分割独立地使用所提出的双通道U-网络,这是由一种新的损失函数称为自适应三重骰子损失(ADTL)驱动。一个测试时间增强(TTA)的方法,其中分割进行了三次轴向图像及其翻转版本的基础上,最终的分割产生的像素多数表决。结果如下:涉及224个3DUS体积的实验产生的CCA中MAB和LIB的Dice相似系数(DSC)分别为95.1% $\pm$ 4.1%和91.6% $\pm$ 6.6%,ICA中MAB和LIB的Dice相似系数(DSC)分别为94.2% $\pm$ 3.3%和89.0% $\pm$ 8.1%。TTA和ATDL独立地对ICA中除LIB外的所有边界的统计学显著改善做出了贡献。分割整个3DUS容积(CCA+ICA)所需的总时间为1.4秒。结论:基于ADTL和TTA的双通道U-Net能够准确有效地从三维超声图像中分割出CCA和ICA。意义:我们的方法有可能加速颈动脉粥样硬化3DUS测量向临床研究的过渡。

英文摘要:

Objective: Vessel-wall-volume (VWV) and localized vessel-wall-thickness (VWT) measured from 3D ultrasound (US) carotid images are sensitive to anti-atherosclerotic effects of medical/dietary treatments. VWV and VWT measurements require the lumen-intima (LIB) and media-adventitia boundaries (MAB) at the common and internal carotid arteries (CCA and ICA). However, most existing segmentation techniques were capable of automating only CCA segmentation. An approach capable of segmenting the MAB and LIB from the CCA and ICA was required to accelerate VWV and VWT quantification. Methods: Segmentation for CCA and ICA were performed independently using the proposed two-channel U-Net, which was driven by a novel loss function known as the adaptive triple Dice loss (ADTL). A test-time augmentation (TTA) approach is used, in which segmentation was performed three times based on axial images and its flipped versions; the final segmentation was generated by pixel-wise majority voting. Results: Experiments involving 224 3DUS volumes produce a Dice-similarity-coefficient (DSC) of 95.1%$\pm$4.1% and 91.6%$\pm$6.6% for the MAB and LIB, in the CCA, respectively, and 94.2%$\pm$3.3% and 89.0%$\pm$8.1% for the MAB and LIB, in the ICA, respectively. TTA and ATDL independently contributed to a statistically significant improvement to all boundaries except the LIB in ICA. The total time required to segment the entire 3DUS volume (CCA+ICA) is 1.4s. Conclusion: The proposed two-channel U-Net with ADTL and TTA can segment the CCA and ICA accurately and efficiently from the 3DUS volume. Significance: Our approach has the potential to accelerate the transition of 3DUS measurements of carotid atherosclerosis to clinical research.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑