提高LUX-ZEPLIN(LZ)暗物质实验对低能信号的灵敏度
Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals
摘要:
两相氙探测器,例如即将到来的LZ暗物质实验的核心,使用光电倍增管来感测液体氙靶中粒子相互作用产生的初级(S1)和次级(S2)闪烁信号。本文描述了一个模拟研究探索两种技术,以降低LZ的能量阈值,获得灵敏度低质量的暗物质和天体物理中微子,这将适用于其他液体氙探测器。能量阈值由检测到的S1光子的数量决定;通常,这些光子必须记录在三个或更多个光电倍增管通道中,以避免模拟真实信号的暗计数重合。要降低此阈值,请执行以下操作:a)我们利用了双光电子发射效应,由此单个真空紫外光子具有从光电倍增管光电阴极发射两个光电子的$\sim20\%$概率;以及b)我们完全放弃了对S1信号的要求,并且仅使用电离信号,这可以更有效地检测。对于这两种技术,我们开发的标称曝光信号和背景模型,并探讨伴随系统的影响,包括在液体氙的自由电子寿命的依赖。当结合双光电子信号,我们预测的$\sim 4$的灵敏度提高的暗物质-核子散射截面在$2.5$ GeV/c $^2$的一个因素,和一个因素的$\sim1.6$增加太阳$^8$ B中微子的检测率。在这两种情况下,降低S1要求可以允许两个数量级的灵敏度增益。最后,我们将这些技术应用到更低的质量,考虑到原子Migdal效应,这可以降低暗物质粒子质量阈值$80$ MeV/c $^2$。
英文摘要:
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。