基于一维卷积神经网络的低质量动态心电图R峰检测

Robust R-Peak Detection in Low-Quality Holter ECGs using 1D Convolutional Neural Network

Qatar University(卡塔尔大学);Izmir University of Economics(伊兹密尔经济大学);Tampere University(坦佩雷大学)

Muhammad Uzair Zahid, Serkan Kiranyaz, Turker Ince, Ozer Can Devecioglu, Muhammad E. H. Chowdhury, Amith Khandakar, Anas Tahir, Moncef Gabbouj

摘要:

从Holter或可穿戴设备采集的ECG信号的噪声和低质量恶化了R峰检测算法的准确性和鲁棒性。本文提出了一种通用且鲁棒的动态心电图信号R峰检测系统。虽然许多提出的算法已经成功地解决了ECG R峰检测的问题,但这些检测器在这种低质量ECG记录上的性能仍然存在显著的差距。因此,在这项研究中,一维卷积神经网络(CNN)的一种新的实现与验证模型集成使用,以减少误报的数量。该CNN架构由编码器块和对应的解码器块组成,随后是逐样本分类层,以从输入ECG信号构建R峰的1D分割图。一旦所提出的模型已经被训练,它可以单独用于快速和准确地检测可能在单通道ECG数据流中的R峰,或者可替代地,这样的解决方案可以方便地用于在轻量级便携式设备上的实时监测。该模型在两个开放访问的ECG数据库上进行了测试:中国生理信号挑战(2020)数据库(CPSC-DB)超过一百万次心跳,以及常用的MIT-BIH心律失常数据库(MIT-DB)。实验结果表明,所提出的系统方法在CPSC-DB中实现了99.30%的F1分数,99.69%的召回率和98.91%的准确率,这是有史以来最好的R峰检测性能。与所有竞争方法相比,所提出的方法可以减少Holter ECG信号中的假阳性和假阴性分别超过54%和82%。结果还表明,与MIT-DB上的大多数竞争算法相比,其性能相似或更好,F1分数为99.83%,召回率为99.85%,准确率为99.82%。

英文摘要:

Noise and low quality of ECG signals acquired from Holter or wearable devices deteriorate the accuracy and robustness of R-peak detection algorithms. This paper presents a generic and robust system for R-peak detection in Holter ECG signals. While many proposed algorithms have successfully addressed the problem of ECG R-peak detection, there is still a notable gap in the performance of these detectors on such low-quality ECG records. Therefore, in this study, a novel implementation of the 1D Convolutional Neural Network (CNN) is used integrated with a verification model to reduce the number of false alarms. This CNN architecture consists of an encoder block and a corresponding decoder block followed by a sample-wise classification layer to construct the 1D segmentation map of R- peaks from the input ECG signal. Once the proposed model has been trained, it can solely be used to detect R-peaks possibly in a single channel ECG data stream quickly and accurately, or alternatively, such a solution can be conveniently employed for real-time monitoring on a lightweight portable device. The model is tested on two open-access ECG databases: The China Physiological Signal Challenge (2020) database (CPSC-DB) with more than one million beats, and the commonly used MIT-BIH Arrhythmia Database (MIT-DB). Experimental results demonstrate that the proposed systematic approach achieves 99.30% F1-score, 99.69% recall, and 98.91% precision in CPSC-DB, which is the best R-peak detection performance ever achieved. Compared to all competing methods, the proposed approach can reduce the false-positives and false-negatives in Holter ECG signals by more than 54% and 82%, respectively. Results also demonstrate similar or better performance than most competing algorithms on MIT-DB with 99.83% F1-score, 99.85% recall, and 99.82% precision.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑