Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response of the scintillator for nearly mono-energetic neutrons has been reported in case of neutron energies E$_n$ =3, 6 and 9 MeV. Important properties (figure-of-merit (FOM), time resolution, detection efficiency) of the detector has been compared with a commonly used liquid organic scintillator based detector of the same size coupled to the same PMT for uniformity in comparison. The results show that the plastic scintillator detector has about 12$\%$ better time resolution. However, the FOM and detection efficiency were found to be lower than that of the liquid scintillator detector by 40 - 50$\%$ and $\sim $25$\%$, respectively. The possibility of using the new plastic scintillator in large-scale nuclear physics experiments has been pointed out.
The Plastic Scintillator Detector (PSD) is one of the main sub-detectors in the DArk Matter Particle Explorer (DAMPE) project. It will be operated over a large temperature range from -$10$ to $30^{\circ}$C, so the temperature effect of the whole detection system should be studied in detail. The temperature dependence of the PSD system is mainly contributed by the three parts: the plastic scintillator bar, the photomultiplier tube (PMT), and the Front End Electronics (FEE). These three parts have been studied in detail and the contribution of each part has been obtained and discussed. The tempe…
The simulation study of the light yield and attenuation in the plastic scintillator was performed. The wavelength shifting fiber readout was embedded in the grooves machined along the entire strip surface. The scintillator strips was irradiated with a radiation source {}^{90}Sr or cosmic muons along and across the strip.
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the anthracene light output. There is a potential to improve this value in the future by the optimization of the additives concentrations.
The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.
We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillator, two solutions that have not been extensively considered. We present a study of the energy distribution in plastic-scintillator tiles, the hit efficiency as a function of the hit position, and a study of the…
In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely proportional to the square root of the energy deposited in the scintillator, and scales to 18ps (sigma) at 1MeV. This result competes with the best ones reported for photomultiplier tubes.
In this study, simulation-based design and optimization studies of a gadolinium loaded segmented plastic scintillator detector are presented for monitoring applications of nuclear reactors in Turkey using antineutrinos. For the first time in the literature, a multivariate analysis technique is introduced to suppress cosmic background for such a reactor antineutrino detector.
Plastic scintillator detectors have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. On the other hand, several articles have reported undesired response dependencies on beam energy and temperature, which enhances the necessity to determine appropriate correction factors. In this work, we studied the light yield temperature dependency of four plastic scintillators (BCF-10, BCF-60, BC-404 and RP-200A) and two clear fibers (BCF-98 and SK-80). Measurements were made using a 50 kVp X-ray beam to produce the scintillation and/or radiol…
We report on the optical and structural properties of plastic scintillators irradiated with neutron beams produced by the IBR-2 reactor of the Frank Laboratory of Neutron Physics in JINR, Dubna. Blue UPS-923A and green plastic scintillators were irradiated with neutron fluence ranging from 10$^{13}$ to 10$^{17}$ n/cm$^2$. Discolouring in the plastic scintillators was observed after irradiation. The effects of radiation damage on the optical and structural properties of the samples were characterized by conducting light yield, light transmission, light fluorescence and Raman spectroscopy studie…
Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the expected time resolution assuming the deposited energy in the scintillator equals to 1MeV and all the scintillation light is collected to the photosensor. In this work we measure this parameter with BC422 plastic scintillator read out by different SiPMs. The best obtained value is about 6ps, which is almost a factor of 3 better compared to our earlier result fr…
Results are presented on R&D efforts to design and build large size veto panels, optimized for underground low background experiments, in the most efficient and economical way using commercially available components. A variety of plastic scintillators, photomultiplier tubes, wavelength shifting fibers, and light reflector combinations were tested. Results of these studies and performance of a 2.2 meter long panel are presented.
A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out at both ends by photomultiplier tubes whose pulse shapes were recorded by waveform digitizers. Results obtained with the WAVECATCHER and SAMPIC digitizers are analyzed and compared. A discussion of the various factors affecting the timing resolution is presented. Prospects for applications of plastic scintillator technology in large-scale particle physics d…
An air shower array of seven plastic scintillation detectors has been built and commissioned at an altitude of 2200 meter above sea level in the Eastern Himalayas (Darjeeling). Continuous measurement of shower rate using this array is going on since the end of January, 2018. The method of measurement and experimental results are presented in this article.
Three-dimensional finely grained plastic scintillator detectors bring many advantages in particle detectors, allowing a massive active target which enables a high-precision tracking of interaction products, excellent calorimetry and a sub-nanosecond time resolution. Whilst such detectors can be scaled up to several-tonnes, as required by future neutrino experiments, a relatively long production time, where each single plastic-scintillator element is independently manufactured and machined, together with potential challenges in the assembly, complicates their realisation. In this manuscript we …
Plastic scintillator detectors are used in high energy physics as well as for diagnostic imaging in medicine, beam monitoring on hadron therapy, muon tomography, dosimetry and many security applications. To combine particle tracking and calorimetry it is necessary to build detectors with three-dimensional granularity, i.e. small voxels of scintillator optically isolated from each other. Recently, the 3DET collaboration demonstrated the possibility to 3D print polystyrene-based scintillators with a light output performance close to that obtained with standard production methods. In this article…
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will eventually comprise a central module of 64 elongated segments of $^{6}$Li-doped pulse-shape-sensitive scintillator rods, each with a square cross section of 5.4 mm $\times$ 5.4 mm, surrounded by larger cro…
A novel plastic scintillator, referred to as J-PET scintillator, has been developed for the application in the digital positron emission tomography (PET). The novelty of the concept lies in application of the 2-(4-styrylphenyl)benzoxazole as a wavelength shifter. To date, the chemical compound has not been used as scintillator additive. A role of wavelength shifter is to shift the scintillation spectrum towards longer wavelengths making it more suitable for applications in scintillators of long strips geometry because of larger attenuation length, and light detection with digital silicon photo…
We have constructed and tested a novel plastic-scintillator-based solid-state active proton target for use in nuclear spectroscopic studies with nuclear reactions induced by an ion beam in inverse kinematics. The active target system, named Stack Structure Solid organic Scintillator Active Target (S4AT), consists of five layers of plastic scintillators, each with a 1-mm thickness. To determine the reaction point in the thickness direction, we exploit the difference in the energy losses due to the beam particle and the charged reaction product(s) in the scintillator material. S4AT offers the pr…
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse beta decay (IBD) signal. ISMRAN detector, an above-ground experiment close to the reactor core (~13m), deals with an active fast neutron background inside the reactor hall. A good understanding of fa…
The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this is accomplished by using 3000 monolithic scintillator bars of 270$\times$5$\times$5 cm$^3$ size made of a fast plastic. Each bar is read out on the two long ends, and the needed time resolution of $σ_t$ $<$ 150 ps is reached with fast timing photomultipliers. In the present work, it is investigated whether silicon photomultiplier (SiPM) photosensors can be …
The NUCLEUS experiment aims at measuring the coherent elastic scattering of nuclear reactor antineutrinos off nuclei using cryogenic calorimeters. Operating at an overburden of 3m.w.e., muon-induced backgrounds are expected to be dominant. It is therefore essential to develop an efficient muon veto, with a detection efficiency of more than 99%. This will be realized in NUCLEUS through a compact cube assembly of plastic scintillator panels. In order to prevent a large unshielded area where the cryostat intersects the shielding arrangement without unnecessarily increasing the induced detector de…
Compact neutron imagers using double-scatter kinematic reconstruction are being designed for localization and characterization of special nuclear material. These neutron imaging systems rely on scintillators with a rapid prompt temporal response as the detection medium. As n-p elastic scattering is the primary mechanism for light generation by fast neutron interactions in organic scintillators, proton light yield data are needed for accurate assessment of scintillator performance. The proton light yield of a series of commercial fast plastic organic scintillators---EJ-200, EJ-204, and EJ-208--…
We demonstrated the feasibility of measuring the axial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons escaping from the scintillator with an array of wavelength-shifting (WLS) strips. Using a test set-up comprising a BC-420 scintillator bar and an~array of sixteen BC-482A WLS strips we achieved a spatial resolution of~5\,mm~($σ$) for annihilation photons from a $^{22}$Na isotope. The studied method can be used to improve the spatial resolution of a plastic-scintillator-based PET scanner which is being developed by the J-…
This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillator, revealing properties which fulfill the requirements of novel positron emission tomography scanners based on plastic scintillators. The key parameters of the manufacturing process are determined and discussed.
The performance of several trigger counters based on plastic scintillators with silicon photomultiplier readout is investigated with cosmic rays. Efficiency and time resolution are measured using digital waveform analysis. The obtained results are relevant for trigger subsystems of Multi-Purpose Detector (MPD) and Baryonic Matter at the Nuclotron (BM@N) at the NICA heavy-ion collider. The results show very high efficiency and good timing performance of the counters.
A new and simple technique has been developed using plastic scintillator detectors for gamma ray and cosmic ray spectroscopy without single channel analyzer (SCA) or multichannel analyzer (MCA). In these experiments only a leading edge discriminator (LED) and NIM scalers have been used. Energy calibration of gamma spectra in plastic scintillators has been done using Co$^{60}$ and Cs$^{137}$ sources. The details experimental technique, analysis procedure and experimental results has been presented in this article.
We propose a new type segmented antineutrino detector made of plastic scintillators for the nuclear safeguard application. A small prototype was built and tested to measure background events. A satisfactory unmanned field operation of the detector system was demonstrated. Besides, a detailed Monte Carlo simulation code was developed to estimate the antineutrino detection efficiency of the detector.
Plastic organic scintillators have been tailored in composition to achieve ultra-fast temporal response, thereby enabling the design and development of fast neutron detection systems with high timing resolution. Eljen Technology's plastic organic scintillators -- EJ-230, EJ-232, and EJ-232Q -- are prospective candidates for use in emerging neutron imaging systems, where fast timing is paramount. To support the neutron response characterization of these materials, the relative proton light yields of EJ-230, EJ-232, and EJ-232Q were measured at the 88-Inch Cyclotron at Lawrence Berkeley National…
We developed a segmented reactor-antineutrino detector made of plastic scintillators for application as a tool in nuclear safeguards inspection and performed mostly unmanned field operations at a commercial power plant reactor. At a position outside the reactor building, we measured the difference in reactor antineutrino flux above the ground when the reactor was active and inactive.
Technology developed for the T2K electromagnetic calorimeter has been adapted to make a small footprint, reliable, segmented detector to characterise anti-neutrinos emitted by nuclear reactors. The device has been developed and demonstrated by the University of Liverpool and underwent field tests at the Wylfa Magnox Reactor on Anglesey, UK. It was situated in a 20\,ft ISO shipping container, above ground, roughly 60\,m from the 1.5\,\GWt\ reactor core. Based on the design of the T2K Near Detector ECal, the device detects anti-neutrinos through the distinctive delayed coincidence signal of inve…
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.
A comparative study of the neutron-$γ$ Pulse Shape Discrimination (PSD) with seven organic scintillators is performed using an identical setup and digital electronics. The scintillators include plastics (EJ-299-33 and a plastic prototype), single crystals (stilbene and the recent doped $p$-terphenyl) and liquids (BC501A, NE213 and the deuterated liquid BC537). First, the overall PSD performance of the different scintillators is compared and threshold neutron energies for a given discrimination quality are determined. Then, using statistical arguments, two intrinsic contributions to the PSD cap…
A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $γ$ rays under high-counting rate has been constructed and tested. To achieve $\it{n}$-$γ$ discrimination, we exploit the difference in the ranges of the secondary charged particles produced by the interactions of neutrons and $γ$ rays in the scintillator material. The thickness of a plastic scintillator layer was determined based on the results of Monte Carlo simulations using the Geant4 toolkit. With layer thicknesses…
In this short note we present results of background measurements carried out with a polystyrene based cast plastic 12.0x12.0x3.0 cm^3 size scintillator counter with a wavelength shifting fibre and a multi-pixel Geiger mode avalanche photodiode readout in the Baksan underground laboratory at a depth of 200 meters of water equivalent. The total counting rate of the scintillator counter measured at this depth and at a threshold corresponding to ~0.37 of a minimum ionizing particle is approximately 1.3 Hz.
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy deposition, number of bars hit as well as topological event selection criteria in position and time. Each of these selection criteria are compared with Monte Carlo based simulations and further an embe…
The High Energy cosmic-Radiation Detector (HERD) facility is planned to go onboard China's Space Station, planned to be operational starting in around 2025 for about 10 years. The main scientific objectives of HERD are the search for signals of dark matter annihilation products, precise cosmic electron/positron spectrum and measurements of anisotropy up to 10 TeV, precise cosmic ray spectrum and composition measurements up to the knee energy (1 PeV), and high energy $γ$-ray monitoring and survey. HERD consists of a 3D cubic crystals calorimeter (CALO) surrounded by microstrip silicon trackers …
Plastic scintillators are widely used in high-energy and medical physics, often for measuring the energy of ionizing radiation. Their main disadvantage is their non-linear response to highly ionizing radiation, called ionization quenching. This nonlinearity must be modeled and corrected for in applications where an accurate energy measurement is required. We present a new experimental technique to granularly measure the dependence of quenching on energy-deposition density. Based on this method, we determine the parameters for four commonly used quenching models for two commonly used plastic sc…
Plastic scintillators are widely used as particle detectors in many fields, mainly, medicine, particle physics and astrophysics. Traditionally, they are coupled to a photo-multplier (PMT) but now silicon photo-multipliers (SiPM) are evolving as a promising robust alternative, specially in space born experiments since plastic scintillators may be a light option for low Earth orbit missions. Therefore it is timely to make a new analysis of the optimal design for experiments based on plastic scintillators in realistic conditions in such a configuration. We analyze here their response to an isotro…
Pixelated Plastic Scintillator Array Manufacturing using Fast-, Photo-Curable Resin
Air Force Institute of Technology(空军理工学院);Oak Ridge National Laboratory(橡树岭国家实验室);Defense Threat Reduction Agency Nuclear Science and Engineering Research Center(国防威胁降低局核科学与工程研究中心)
The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its final configuration, NeuLAND will consist of 3000 2.7 m $\times$ 5 cm $\times$ 5 cm big plastic scintillator bars that are read out on each end by fast timing photomultipliers. Here, data from a comprehensive study of an alternative light readout scheme using silicon photomultipliers (SiPM) are reported. For this purpose, a NeuLAND bar was instrumented on each …
The results of a development of a scintillator counter with wavelength shifting (WLS) fibre and a multi-pixel Geiger-mode avalanche photodiode readout are presented. The photodiode has a metal-resistor-semiconductor layered structure and operates in the limited Geiger mode. The scintillator counter has been developed for the EMMA underground cosmic ray experiment.
This work presents the design and performance study of compact strips of plastic scintillator with WLS-fiber readout in a dimension of 0.1 * 0.02 * 2 m3, which evaluates as a candidate for cosmic-ray muon detector for JUNO-TAO. The strips coupling with 3-inch PMTs are measured and compared between the single-end and double-end readout options first, and the strip of double-end option coupling with SiPM is further measured and compared with the results of that with the PMTs. The performance of the strips determined by a detailed survey along their length with cosmic-ray muon after a detailed ch…
In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided…
A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presently used Positron Emission Tomography scanners.
Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the balance between processing and performance at the kilogram scale. These trade-offs were necessitated by the inclusion of 0.1 wt. % lithium-6 to enable detection of thermal neutrons. The synthesis and processing of these plastic scintillators on the kilogram scale required consideration of many factors. First, a comonomer (methacrylic acid) was used to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that pr…
Scintillator doped with a high neutron-capture cross-section material can be used to detect neutrons via their resulting gamma rays. Examples of such detectors using liquid scintillator have been successfully used in high-energy physics experiments. However, a liquid scintillator can leak and is not as amenable to modular or complex shapes as a solid scintillator. Polystyrene-based scintillators from a variety of gadolinium compounds with varying concentrations were polymerized in our laboratory. The light output, emission spectra, and attenuation length of our samples were measured and light …