Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
University of Texas Southwestern Medical Center(德克萨斯大学西南医学中心);University of Utah(犹他大学);Peking University(北京大学);Rensselaer Polytechnic Institute(伦斯勒理工学院);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院)
Ti Bai, Biling Wang, Dan Nguyen, Bao Wang, Bin Dong, Wenxiang Cong, Mannudeep K. Kalra, Steve Jiang
Low dose computed tomography (LDCT) is desirable for both diagnostic imaging and image guided interventions. Denoisers are openly used to improve the quality of LDCT. Deep learning (DL)-based denoisers have shown state-of-the-art performance and are becoming one of the mainstream methods. However, there exists two challenges regarding the DL-based denoisers: 1) a trained model typically does not generate different image candidates with different noise-resolution tradeoffs which sometimes are needed for different clinical tasks; 2) the model generalizability might be an issue when the noise level in the testing images is different from that in the training dataset. To address these two challenges, in this work, we introduce a lightweight optimization process at the testing phase on top of any existing DL-based denoisers to generate multiple image candidates with different noise-resolution tradeoffs suitable for different clinical tasks in real-time. Consequently, our method allows the users to interact with the denoiser to efficiently review various image candidates and quickly pick up the desired one, and thereby was termed as deep interactive denoiser (DID). Experimental results demonstrated that DID can deliver multiple image candidates with different noise-resolution tradeoffs, and shows great generalizability regarding various network architectures, as well as training and testing datasets with various noise levels.
Optical Coherence Tomography (OCT) is pervasive in both the research and clinical practice of Ophthalmology. However, OCT images are strongly corrupted by noise, limiting their interpretation. Current OCT denoisers leverage assumptions on noise distributions or generate targets for training deep supervised denoisers via averaging of repeat acquisitions. However, recent self-supervised advances allow the training of deep denoising networks using only repeat acquisitions without clean targets as ground truth, reducing the burden of supervised learning. Despite the clear advantages of self-superv…
University of Oulu(奥卢大学);University College London(伦敦大学学院)
Multi-energy computed tomography (CT) with photon counting detectors (PCDs) enables spectral imaging as PCDs can assign the incoming photons to specific energy channels. However, PCDs with many spectral channels drastically increase the computational complexity of the CT reconstruction, and bespoke reconstruction algorithms need fine-tuning to varying noise statistics. \rev{Especially if many projections are taken, a large amount of data has to be collected and stored. Sparse view CT is one solution for data reduction. However, these issues are especially exacerbated when sparse imaging scenar…
Joint ptycho-tomography is a powerful computational imaging framework to recover the refractive properties of a 3D object while relaxing the requirements for probe overlap that is common in conventional phase retrieval. We use an augmented Lagrangian scheme for formulating the constrained optimization problem and employ an alternating direction method of multipliers (ADMM) for the joint solution. ADMM allows the problem to be split into smaller and computationally more efficient subproblems: ptychographic phase retrieval, tomographic reconstruction, and regularization of the solution. We exten…
This work systematically investigates the adversarial robustness of deep image denoisers (DIDs), i.e, how well DIDs can recover the ground truth from noisy observations degraded by adversarial perturbations. Firstly, to evaluate DIDs' robustness, we propose a novel adversarial attack, namely Observation-based Zero-mean Attack ({\sc ObsAtk}), to craft adversarial zero-mean perturbations on given noisy images. We find that existing DIDs are vulnerable to the adversarial noise generated by {\sc ObsAtk}. Secondly, to robustify DIDs, we propose an adversarial training strategy, hybrid adversarial t…
Hunan University of Science and Technology(湖南科技大学);Nanjing First Hospital, Nanjing Medical University(南京医科大学附属南京第一医院);University of Macau(澳门大学);Nanjing University of Posts and Telecommunications(南京邮电大学)
Compressive sensing (CS) based computed tomography (CT) image reconstruction aims at reducing the radiation risk through sparse-view projection data. It is usually challenging to achieve satisfying image quality from incomplete projections. Recently, the nonconvex ${L_ {1/2}} $-norm has achieved promising performance in sparse recovery, while the applications on imaging are unsatisfactory due to its nonconvexity. In this paper, we develop a ${L_ {1/2}} $-regularized nonlocal self-similarity (NSS) denoiser for CT reconstruction problem, which integrates low-rank approximation with group sparse …
University of Texas Southwestern Medical Centre(德克萨斯大学西南医学中心)
Low Dose Computed Tomography (LDCT) is clinically desirable due to the reduced radiation to patients. However, the quality of LDCT images is often sub-optimal because of the inevitable strong quantum noise. Inspired by their unprecedent success in computer vision, deep learning (DL)-based techniques have been used for LDCT denoising. Despite the promising noise removal ability of DL models, people have observed that the resolution of the DL-denoised images is compromised, decreasing their clinical value. Aiming at relieving this problem, in this work, we developed a more effective denoiser by …
A new Plug-and-Play (PnP) alternating direction of multipliers (ADMM) scheme is proposed in this paper, by embedding a recently introduced adaptive denoiser using the Schroedinger equation's solutions of quantum physics. The potential of the proposed model is studied for Poisson image deconvolution, which is a common problem occurring in number of imaging applications, such as limited photon acquisition or X-ray computed tomography. Numerical results show the efficiency and good adaptability of the proposed scheme compared to recent state-of-the-art techniques, for both high and low signal-to-…
Washington University in St. Louis(圣路易斯华盛顿大学);Los Alamos National Laboratory(洛斯阿拉莫斯国家实验室)
Plug-and-play priors (PnP) is a powerful framework for regularizing imaging inverse problems by using advanced denoisers within an iterative algorithm. Recent experimental evidence suggests that PnP algorithms achieve state-of-the-art performance in a range of imaging applications. In this paper, we introduce a new online PnP algorithm based on the iterative shrinkage/thresholding algorithm (ISTA). The proposed algorithm uses only a subset of measurements at every iteration, which makes it scalable to very large datasets. We present a new theoretical convergence analysis, for both batch and on…
Institute for Information Transmission Problems (Kharhevich Institute) Russian Academy of Sciences(俄罗斯科学院信息传输问题研究所(哈恰耶维奇研究所));Smart Engines(Smart Engines公司);Institute of Microelectronics Technology and High-Purity Materials Russian Academy of Sciences(俄罗斯科学院微电子技术与高纯材料研究所);FSRC “Crystallography and Photonics” Russian Academy of Sciences(俄罗斯科学院“晶体学和光子学”联邦研究中心);Merzhanov Institute of Structural Macrokinetics and Materials Science Russian Academy of Sciences(俄罗斯科学院梅尔扎诺夫结构宏观动力学与材料科学研究所)
Porous materials are widely used in different applications, in particular they are used to create various filters. Their quality depends on parameters that characterize the internal structure such as porosity, permeability and so on. Computed tomography (CT) allows one to see the internal structure of a porous object without destroying it. The result of tomography is a gray image. To evaluate the desired parameters, the image should be segmented. Traditional intensity threshold approaches did not reliably produce correct results due to limitations with CT images quality. Errors in the evaluati…
Two features desired in a three-dimensional (3D) optical tomographic image reconstruction algorithm are the ability to reduce imaging artifacts and to do fast processing of large data volumes. Traditional iterative inversion algorithms are impractical in this context due to their heavy computational and memory requirements. We propose and experimentally validate a novel scalable iterative mini-batch algorithm (SIMBA) for fast and high-quality optical tomographic imaging. SIMBA enables high-quality imaging by combining two complementary information sources: the physics of the imaging system cha…
Centrum Wiskunde & Informatica(荷兰国家数学与计算机科学研究中心);Leiden Institute of Advanced Computer Science, Leiden Universiteit(莱顿大学高级计算机科学研究所)
Recovering a high-quality image from noisy indirect measurements is an important problem with many applications. For such inverse problems, supervised deep convolutional neural network (CNN)-based denoising methods have shown strong results, but the success of these supervised methods critically depends on the availability of a high-quality training dataset of similar measurements. For image denoising, methods are available that enable training without a separate training dataset by assuming that the noise in two different pixels is uncorrelated. However, this assumption does not hold for inve…
Discriminating retinal microvascular and neuronal differences related to migraines: Deep Learning based Crossectional Study
Monash University(莫纳什大学);University of New South Wales(新南威尔士大学);School of Optometry & Vision Science(视光与视觉科学学院);School of Computer Science and Engineering(计算机科学与工程学院)
Michigan State University(密歇根州立大学);Los Alamos National Laboratory(洛斯阿拉莫斯国家实验室)
Object density reconstruction from projections containing scattered radiation and noise is of critical importance in many applications. Existing scatter correction and density reconstruction methods may not provide the high accuracy needed in many applications and can break down in the presence of unmodeled or anomalous scatter and other experimental artifacts. Incorporating machine-learned models could prove beneficial for accurate density reconstruction particularly in dynamic imaging, where the time-evolution of the density fields could be captured by partial differential equations or by le…
Washington University in St. Louis(圣路易斯华盛顿大学);Mallinckrodt Institute of Radiology(马林克罗特放射学研究所)
Multiple objective assessment of image-quality-based studies have reported that several deep-learning-based denoising methods show limited performance on signal-detection tasks. Our goal was to investigate the reasons for this limited performance. To achieve this goal, we conducted a task-based characterization of a DL-based denoising approach for individual signal properties. We conducted this study in the context of evaluating a DL-based approach for denoising SPECT images. The training data consisted of signals of different sizes and shapes within a clustered-lumpy background, imaged with a…
Korea Advanced Institute of Science and Technology (KAIST)(韩国科学技术院);Chung-Ang University Hospital(中央大学医院);Chung-Ang University College of Medicine(中央大学医学院)
Patient scans from MRI often suffer from noise, which hampers the diagnostic capability of such images. As a method to mitigate such artifact, denoising is largely studied both within the medical imaging community and beyond the community as a general subject. However, recent deep neural network-based approaches mostly rely on the minimum mean squared error (MMSE) estimates, which tend to produce a blurred output. Moreover, such models suffer when deployed in real-world sitautions: out-of-distribution data, and complex noise distributions that deviate from the usual parametric noise models. In…
Center for Advanced Medical Computing and Analysis(高级医学计算与分析中心);Gordon Center for Medical Imaging(戈登医学成像中心);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院)
Dynamic computed tomography perfusion (CTP) imaging is a promising approach for acute ischemic stroke diagnosis and evaluation. Hemodynamic parametric maps of cerebral parenchyma are calculated from repeated CT scans of the first pass of iodinated contrast through the brain. It is necessary to reduce the dose of CTP for routine applications due to the high radiation exposure from the repeated scans, where image denoising is necessary to achieve a reliable diagnosis. In this paper, we proposed a self-supervised deep learning method for CTP denoising, which did not require any high-dose referenc…
University of Texas Southwestern Medical Center(德克萨斯大学西南医学中心)
Since the outbreak of the COVID-19 pandemic, worldwide research efforts have focused on using artificial intelligence (AI) technologies on various medical data of COVID-19-positive patients in order to identify or classify various aspects of the disease, with promising reported results. However, concerns have been raised over their generalizability, given the heterogeneous factors in training datasets. This study aims to examine the severity of this problem by evaluating deep learning (DL) classification models trained to identify COVID-19-positive patients on 3D computed tomography (CT) datas…