arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2011.03871nucl-ex
收藏

$^{12}$ C(p,po)的激发函数,Ep=16 $÷$ 19.5 MeV,通过MSS测量,分辨率约为10 keV

Excitation Function of $^{12}$C(p,po) for Ep=16 $÷$ 19.5 MeV measured by MSS with resolution ~10 keV

A. Gafarov

摘要:

弹性散射$^{12}$ C(p,在14角磁谱仪(Apelsin)上,用MSS谱叠加法测量了能区Ep =16 - 19.5MeV的激发函数(EF),分辨率约为10 keV乌兹别克斯坦科学院(塔什干)[1-8]。所获得的EF具有与阈值和水平数据精确一致的异常范围结构[2,9 -12]。在厚度为13 mg/cm 2、Apelsin中心面积为1 cm 2的12 C自支撑靶上进行测量。20步能量调节器控制质子能量,提供3.5 MeV宽的Ep间隔,无需重新调整回旋加速器和41米长的束管上的所有离子光学器件。Apelsin对质子的能量分辨率在整个焦平面上优于5 keV,其中粒子产物由专门设计的坐标敏感混合气体MWPC与两个粒子计数器同时探测。采集系统基于IBM PC联机,带有快速CAMAC分支(在圣彼得堡PNPI定制设计),具有快速TDC模块和其他快速电子设备,可立即选择和积累来自MWPC的事件。NMR监测系统将光谱仪的磁场稳定在3 ppm [1,9]。12 C(p,po)散射的EF具有许多精确对应于g.s.和已知产物核的水平。但80%的异常现象没有任何解释。提出了一个新的概念来解释所有未被识别的异常。写作I和写作II提出了两个表达式来解释对应于A13相体积态布居的未知峰。所提出的解释的结果看起来非常有希望(图13)。提出了组合等压共振的概念

英文摘要:

The elastic scattering $^{12}$C(p,po) Excitation Function (EF) was measured in the energy range Ep =16 - 19.5 MeV with resolution about 10 keV by means of innovative approach - MSS - the Method of Spectra Superposition at the 14-angle Magnetic Spectrograph (Apelsin) at beam with an energy spread of about 200 keV from U-150 cyclotron of INP Ulugbek (Tashkent) of Science Academy of Uzbekistan [1-8]. The obtained EF has a reach structure of anomalies in precise agreement with thresholds and levels data [2,9-12]. Measurements were done on the 12C self-supporting target with thickness 13 mg/cm2 and an area of 1 cm2 in the center of Apelsin. The 20-step Energy Moderator controlled the proton energy, providing a 3.5 MeV wide Ep interval with no readjustment of cyclotron and all the ionic-optics on the 41-meter-long beam-pipe. Energy resolution of Apelsin for protons is better than 5 keV along all focal plane, where particle-product were detected by specially designed coordinate-sensitive gas mixture MWPC with two particle counters in coincidence. The acquisition system was based on IBM PC online with a fast CAMAC branch (custom designed at St-Petersburg PNPI) with fast TDC modules and other fast electronics providing immediate selection and accumulations of events from MWPCs. The NMR-monitor system stabilized spectrographs magnetic field to 3ppm [1,9]. The EF of 12C (p,po) scattering has many resonances that precisely correspond to g.s. and levels of well-known product-nuclei. But 80 percent of anomalies did not have any explanation. A new concept is proposed to explain all unrecognized anomalies. Two expressions Writing I and Writing II proposed to explain the unknown peaks which corresponds to population of A13 phase volume states. The results of the proposed explanation look very promising (Fig. 13). Concept of the Combinative Isobaric Resonances (CIRs) proposed

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑