Motivated by the inadequacy of the existing control strategies for power systems affected by time-varying uncontrolled power injections such as loads and the increasingly widespread renewable energy sources, this paper proposes two control schemes based on the well-known output regulation control methodology. The first one is designed based on the classical output regulation theory and addresses the so-called Load Frequency Control (LFC) problem in presence of time-varying uncontrolled power injections. Then, in order to also minimize the generation costs, we use an approximate output regulation method that solves numerically only the partial differential equation of the regulator equation and propose a controller based on this solution, minimizing an appropriate penalty function. An extensive case study shows excellent performance of the proposed control schemes in different and critical scenarios.
This paper proposes a control method for allowing aggregates of thermostatically controlled loads to provide synthetic inertia and primary frequency regulation services to the grid. The proposed control framework is fully distributed and basically consists in the modification of the thermostat logic as a function of the grid frequency. Three strategies are considered: in the first one, the load aggregate provides synthetic inertia by varying its active power demand proportionally to the frequency rate of change; in the second one, the load aggregate provides primary frequency regulation by var…
Rapid developments in power distribution systems and renewable energy have widened the applications of dc--dc buck--boost converters in dc voltage regulation. Applications include vehicular power systems, renewable energy sources that generate power at a low voltage, and dc microgrids. It is noted that the cascade--connection of converters in these applications may cause instability due to the fact that converters acting as loads have a constant power load (CPL) behavior. In this paper, the output voltage regulation problem of a buck--boost converter feeding a CPL is addressed. The constructio…
A voltage regulation method for slow voltage variations at distribution level is proposed, based on a view of the loads, generators and storage along a distribution line as point weights. The "centers of mass" of the absorbed and injected currents (loads & generation, respectively) are compensated by minimizing the distance between them, through proper re-dispatching of the power of the available units and interruptible loads. The technique is recursively applied to lesser parts of the distribution line to address local phenomena and is assumed to be offered as ancillary service to the system …
In this paper, the highly acknowledged advantages of the Model Predictive Control (MPC) approach are utilized to regulate the wind turbines' output power in the partial load region. In this region, the purpose of the designed controller is to capture maximum power from the wind. When the wind speed is above rated wind speed (full load region), control strategy is to keep output power and generator speed at their rated value. Because of the wind turbine's nonlinearities and constraints of the variables this is a challenging problem and two MPC-based methods are proposed, i.e. online and offline…
In this paper we present new (stochastic) passivity properties for Direct Current (DC) power networks, where the unknown and unpredictable load demand is modelled by a stochastic process. More precisely, the considered power network consists of distributed generation units supplying ZIP loads, i.e., nonlinear loads comprised of impedance (Z), current (I) and power (P) components. Differently from the majority of the results in the literature, where each of these components is assumed to be constant, we consider time-varying loads whose dynamics are described by a class of stochastic differenti…
In order to deal with issues caused by the increasing penetration of renewable resources in power systems, this paper proposes a novel distributed frequency control algorithm for each generating unit and controllable load in a transmission network to replace the conventional automatic generation control (AGC). The targets of the proposed control algorithm are twofold. First, it is to restore the nominal frequency and scheduled net inter-area power exchanges after an active power mismatch between generation and demand. Second, it is to optimally coordinate the active powers of all controllable …
Optimising wind turbine performance involves maximising energy harvesting while seeking to minimise load fatigues on the tower structure, blades and rotor. To improve turbine control performance, wind preview measurement technologies such as Light Detection And Ranging (LIDAR) have been a point of interest for researchers in recent years. In this paper, we explore the application of a classical control methodology known as Exact Output Regulation (EOR) for improving the control performance of a LIDAR-enhanced wind turbine. The EOR controller is designed to achieve the rejection of known input …
In this paper, a novel adaptive optimal control strategy is proposed to achieve the cooperative optimal output regulation of continuous-time linear multi-agent systems based on adaptive dynamic programming (ADP). The proposed method is different from those in the existing literature of ADP and cooperative output regulation in the sense that the knowledge of the exosystem dynamics is not required in the design of the exostate observers for those agents with no direct access to the exosystem. Moreover, an optimal control policy is obtained without the prior knowledge of the modeling information …
Cooperative Control of Parallel Actuators for Linear Robust Output Regulation of Uncertain Linear Minimum-phase Plants
School of Mathematics and Statistics, Fuzhou University(福州大学数学与统计学院);Guangdong Provincial Key Laboratory of Fully Actuated System Control Theory and Technology, School of Automation and Intelligent Manufacturing, Southern University of Science and Technology(南方科技大学自动化与智能制造学院)
In this paper we consider the problem of voltage regulation of a proton exchange membrane fuel cell connected to an uncertain load through a boost converter. We show that, in spite of the inherent nonlinearities in the current-voltage behaviour of the fuel cell, the voltage of a fuel cell/boost converter system can be regulated with a simple proportional-integral (PI) action designed following the {Passivity-based Control (PBC) approach. The system under consideration consists of a DC-DC converter interfacing a fuel cell with a resistive load. We show that the output voltage of the converter c…
This paper proposes a new single input multiple output power supply by integrating a flyback converter and several buck converters. The flyback converter works as the main regulator, and the buck converters provide series voltage compensation with the aim of tight regulation. A time multiplexing switching scheme is proposed to deliver multiple output voltage levels via a two winding transformer and to eliminate the cross regulation between output channels. This configuration reduces the size of flyback transformer and filter capacitors, and consequently improves the overall form factor. A deta…
In this paper, a novel robust output regulation control framework is proposed for the system subject to noise, modeled disturbance and unmodeled disturbance to seek tracking performance and robustness simultaneously. The output regulation scheme is utilized in the framework to track the reference in the presence of modeled disturbance, and the effect of unmodeled disturbance is reduced by an $\mathcal{H}_\infty$ compensator. The Kalman filter can be also introduced in the stabilization loop to deal with the white noise. Furthermore, the tracking error in the presence/absence of noise and distu…
With the large-scale integration of renewable power generation, frequency regulation resources (FRRs) are required to have larger capacities and faster ramp rates, which increases the cost of the frequency regulation ancillary service. Therefore, it is necessary to consider the frequency regulation cost and constraint along with real-time economic dispatch (RTED). In this paper, a data-driven distributionally robust optimization (DRO) method for RTED considering automatic generation control (AGC) is proposed. First, a Copula-based AGC signal model is developed to reflect the correlations among…
This paper deals with the problem of adaptive output regulation for multivariable nonlinear systems by presenting a learning-based adaptive internal model-based design strategy. The approach builds on the recently proposed adaptive internal model design techniques based on the theory of nonlinear Luenberger observers, and the adaptation side is approached as a probabilistic regression problem. In particular, Gaussian process priors are employed to cope with the learning problem. Unlike the previous approaches in the field, here only coarse assumptions about the friend structure are required, m…
In this paper we propose a new design paradigm, which employing a postprocessing internal model unit, to approach the problem of output regulation for a class of multivariable minimum-phase nonlinear systems possessing a partial normal form. Contrary to previous approaches, the proposed regulator handles control inputs of dimension larger than the number of regulated variables, provided that a controllability assumption holds, and can employ additional measurements that need not to vanish at the ideal error-zeroing steady state, but that can be useful for stabilization purposes or to fulfil th…
This study focuses on periodic event-triggered (PET) cooperative output regulation problem for a class of nonlinear multi-agent systems. The key feature of PET mechanism is that event-triggered conditions are required to be monitored only periodically. This approach is beneficial for Zeno behavior exclusion and saving of battery energy of onboard sensors. At first, new PET distributed observers are proposed to estimate the leader information. We show that the estimation error converges to zero exponentially with a known convergence rate under asynchronous PET communication. Second, a novel PET…
This paper deals with the output regulation problem of a linear time-invariant system in the presence of sporadically available measurement streams. A regulator with a continuous intersample injection term is proposed, where the intersample injection is provided by a linear dynamical system and the state of which is reset with the arrival of every new measurement updates. The resulting system is augmented with a timer triggering an instantaneous update of the new measurement and the overall system is then analyzed in a hybrid system framework. With the Lyapunov based stability analysis, we off…
We consider the problem of designing a state feedback control law to achieve nonovershooting tracking for feedback linearisable multiple-input multiple-output nonlinear systems. The reference signal is assumed to be obtained from a linear exosystem. The design method adopts known methods for the nonovershooting tracking of linear systems and extends them to the output regulation of feedback linearisable nonlinear systems. The method accommodates arbitrary initial conditions and offers design choice of the tracking convergence speed.
We investigate the problem of practical output regulation, i.e., to design a controller that brings the system output in the vicinity of a desired target value while keeping the other variables bounded. We consider uncertain systems that are possibly nonlinear and the uncertainty of their linear parts is modeled element-wise through a parametric family of matrix boxes. An optimization-based design procedure is proposed that delivers a continuous-time control and estimates the maximal regulation error. We also analyze an event-triggered emulation of this controller, which can be implemented on …
This study considers the problem of periodic event-triggered (PET) cooperative output regulation for a class of linear multi-agent systems. The advantage of the PET output regulation is that the data transmission and triggered condition are only needed to be monitored at discrete sampling instants. It is assumed that only a small number of agents can have access to the system matrix and states of the leader. Meanwhile, the PET mechanism is considered not only in the communication between various agents, but also in the sensor-to-controller and controller-to-actuator transmission channels for e…
Distributed Output Regulation for a Class of Nonlinear Multi-Agent Systems with Unknown-Input Leaders
School of Automation, Beijing University of Posts and Telecommunications(北京邮电大学自动化学院);Key Laboratory of Systems and Control, Institute of Systems Science, Chinese Academy of Sciences(中国科学院系统与控制重点实验室,系统科学研究所)
Politecnico di Milano(米兰理工大学);Nanyang Technological University(南洋理工大学);Huazhong University of Science and Technology(华中科技大学);University of Groningen(格罗宁根大学)