Temperature below 100 microKelvin is achieved in a customized cryogen-free dilution refrigerator with a copper-nuclear demagnetization stage. The lowest temperature of conduction electrons of the demagnetization stage is below 100 microKelvin as measured by a pulsed platinum NMR thermometer and the temperature can remain below 100 microKelvin for over 10 hours. An up to 9 T demagnetization magnetic field and an up to 12 T research magnetic field can be controlled independently, provided by a coaxial room-temperature-bore cryogen-free magnet.
We present a parallel network of 16 demagnetization refrigerators mounted on a cryofree dilution refrigerator aimed to cool nanoelectronic devices to sub-millikelvin temperatures. To measure the refrigerator temperature, the thermal motion of electrons in a Ag wire -- thermalized by a spot-weld to one of the Cu nuclear refrigerators -- is inductively picked-up by a superconducting gradiometer and amplified by a SQUID mounted at 4 K. The noise thermometer as well as other thermometers are used to characterize the performance of the system, finding magnetic field independent heat-leaks of a few …
Improved accessibility to the microkelvin temperature regime is important for future research in quantum materials; for quantum information science; and for applications of quantum sensors. Here we report the design and performance of a microkelvin platform based on a nuclear demagnetization stage, engineered and well optimized for operation on a standard cryogen-free dilution refrigerator. PrNi5 is used as the dominant refrigerant. The platform provides a large area for mounting experiments in an ultralow temperature, low electromagnetic noise environment. The performance is characterized usi…
We report experimental demonstration of the feasibility of reaching temperatures below 1 mK using cryogen-free technology. Our prototype system comprises an adiabatic nuclear demagnetisation stage, based on hyperfine-enhanced nuclear magnetic cooling, integrated with a commercial cryogen-free dilution refrigerator and 8 T superconducting magnet. Thermometry was provided by a current-sensing noise thermometer. The minimum temperature achieved at the experimental platform was 600 μK. The platform remained below 1 mK for over 24 hours, indicating a total residual heat-leak into the experimental s…
We report on our design of a scanning gate microscope housed in a cryogen-free dilution refrigerator with a base temperature of 15 mK. The recent increase in efficiency of pulse tube cryocoolers has made cryogen-free systems popular in recent years. However, this new style of cryostat presents challenges for performing scanning probe measurements, mainly as a result of the vibrations introduced by the cryocooler. We demonstrate scanning with root-mean-square vibrations of 0.8 nm at 3 K and 2.1 nm at 15 mK in a 1 kHz bandwidth with our design.
Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts at the cold end, pulse tube cryocoolers introduce vibrations that can be detrimental to the experiments. We characterize the coupling of these vibrations to the electrical signal observed on cables installed in a cryogen-free dilution refrigerator. The dominant electrical noise is in the 5 to 10 kHz range and its magnitude is found to be strongly temperatur…
Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons or residual helium. We present the design and performance of a hermetic cell installed on the mixing chamber plate of a cryogen-free dilution refrigerator. The performance was quantified by measuring the dependence of the resonance frequency of a mechanical oscillator installed inside the cell on the mixing chamber temperature down to 10 mK. We found the expe…
We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss the design guidelines necessary to meet the competing requirements of having a low mechanical stiffness in combination with a high thermal conductance. We demonstrate the effectiveness of our approach by measuring the vibrational noise levels of an ultrasoft mechanical resonator positioned above a SQUID. Starting from a cryostat base temperature of 8 mK, the…
Silicon double paddle osillators (DPO) have been successfully used for measuring the elastic properties of amorphous films down to 10 mK (see for example \cite{Fefferman16,Liu14}). Until now, our group has used a wet dilution refrigerator for the lowest temperature measurements. We present measurements carried out on a Bluefors cryogen-free dilution refrigerator that demonstrate an extreme sensitivity of the thermal coupling of the DPO to its environment. These measurements show that it is necessary to enclose the DPO in a shield at the mixing chamber (MXC) temperature. Any gaps in the shield …
Pulse tube refrigerators are becoming more common, because they are cost efficient and demand less handling than conventional (wet) refrigerators. However, a downside of a pulse tube system is the vibration level at the cold-head, which is in most designs several micrometers. We implemented vibration isolation techniques which significantly reduced vibration levels at the experiment. These optimizations were necessary for the vibration sensitive Magnetic Resonance Force Microscopy experiments (MRFM) at milli-kelvin temperatures for which the cryostat is intended. With these modifications we sh…
Fragile quantum effects such as single electron charging in quantum dots or macroscopic coherent tunneling in superconducting junctions are the basis of modern quantum technologies. These phenomena can only be observed in devices where the characteristic spacing between energy levels exceeds the thermal energy, $k_\textrm{B}T$, demanding effective refrigeration techniques for nanoscale electronic devices. Commercially available dilution refrigerators have enabled typical electron temperatures in the $10$ to $100\,$mK regime, however indirect cooling of nanodevices becomes inefficient due to st…
Traceable In Situ Microwave Power Measurement at the Cryogenic Device Plane in a Dilution Refrigerator
Politecnico di Torino(都灵理工大学);University of Palermo(巴勒莫大学);Istituto Nazionale di Ricerca Metrologica (INRiM)(意大利国家计量研究所);Università degli Studi di Pisa(比萨大学)
Vibrational sensing at mK temperatures in dry dilution refrigerators using commercial accelerometers for diverse fundamental physics applications
INFN -- Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所大萨索国家实验室);University of Pittsburgh(匹兹堡大学);Virginia Polytechnic Institute and State University(弗吉尼亚理工大学);Massachusetts Institute of Technology(麻省理工学院)
We present the evaluation of two different design configurations of a two-stage PrNi$_5$ continuous nuclear demagnetization refrigerator. Serial and parallel configurations of the two stages are considered, with emphasis on the attainable cooling power at sub-mK temperatures and the impact of the design choices on the operation of the refrigerator. Numerical simulations of heat transfer in the setup are used to evaluate the performance of the refrigerator as well as the technological requirements for the essential thermal links. In accord with similar findings for adiabatic demagnetization ref…
In this article we summarize experimental work on cryogen-free 3He/4He dilution refrigerators which, in addition to the dilution refrigeration circuit, are equipped with a 4He-1K-stage. This type of DR becomes worth considering when high cooling capacities are needed at T ~ 1 K to cool cold amplifiers and heat sink cables. In our application, the motivation for the construction of this type of cryostat was to do experiments on superconducting quantum circuits for quantum information technology and quantum simulations. In other work, DRs with 1K-stage were proposed for astro-physical cryostats.…
Magnetic fields are a standard tool in the toolbox of every physicist, and are required for the characterization of materials, as well as the polarization of spins in nuclear magnetic resonance or electron paramagnetic resonance experiments. Quite often a static magnetic field of sufficiently large, but fixed magnitude is suitable for these tasks. Here we present a permanent magnet assembly that can achieve magnetic field strengths of up to 1.5T over an air gap length of 7mm. The assembly is based on a Halbach array of neodymium (NdFeB) magnets, with the inclusion of the soft magnetic material…
We present the design and operation of a fiber-based cryogenic confocal microscope. It is designed as a compact cold-finger that fits inside the bore of a superconducting magnet, and which is a modular unit that can be easily swapped between use in a dilution refrigerator and other cryostats. We aimed at application in quantum optical experiments with electron spins in semiconductors and the design has been optimized for driving with, and detection of optical fields with well-defined polarizations. This was implemented with optical access via a polarization maintaining fiber together with Voig…
We describe the design and in--flight performance of the cryostat and the self-contained $^{3}$He refrigerator for the OLIMPO balloon--borne experiment, a spectrophotometer to measure the Sunyaev-Zel'dovich effect in clusters of galaxies. The $^{3}$He refrigerator provides the 0.3 K operation temperature for the four arrays of kinetic inductance detectors working in 4 bands centered at 150, 250, 350 and 460 GHz. The cryostat provides the 1.65 K base temperature for the $^{3}$He refrigerator, and cools down the reimaging optics and the filters chain at about 2 K. The integrated system was desig…
At the Walther-Meißner-Institut (WMI), a new cryogen-free 3He/4He dilution refrigerator (DR) has been completed; the cryostat will be employed to cool experiments on superconducting quantum circuits for quantum information technology and quantum simulations. All major components have been made at the WMI. The DR offers lots of space at the various stages of the apparatus for microwave components and cables. E. g., the usable space at the mixing chamber has a height of more than 60 cm and a diameter of 30 cm (mixing chamber mounting plate). To cool cables and cold amplifiers, the DR is equipped…
The external shell of the CUORE cryostat is a large cryogen-free system designed to host the dilution refrigerator and the bolometers of the CUORE experiment in a low radioactivity environment. The three vessels that form the outer shell were produced and delivered to the Gran Sasso underground Laboratories in July 2012. In this paper, we describe the production techniques and the validation tests done at the production site in 2012.