Purpose: Many useful image quality metrics for evaluating linear image reconstruction techniques do not apply to or are difficult to interpret for non-linear image reconstruction. The vast majority of metrics employed for evaluating non-linear image reconstruction are based on some form of global image fidelity, such as image root mean square error (RMSE). Use of such metrics can lead to over-regularization in the sense that they can favor removal of subtle details in the image. To address this shortcoming, we develop an image quality metric based on signal detection that serves as a surrogate to the qualitative loss of fine image details. Methods: The metric is demonstrated in the context of a breast CT simulation, where different equal-dose configurations are considered. The configurations differ in the number of projections acquired. Image reconstruction is performed with a non-linear algorithm based on total variation constrained least-squares (TV-LSQ). The images are evaluated visually, with image RMSE, and with the proposed signal-detection based metric. The latter uses a small signal, and computes detectability in the sinogram and in the reconstructed image. Loss of signal detectability through the image reconstruction process is taken as a quantitative measure of loss of fine details in the image. Results: Loss of signal detectability is seen to correlate well with the blocky or patchy appearance due to over-regularization with TV-LSQ, and this trend runs counter to the image RMSE metric, which tends to favor the over-regularized images. Conclusions: The proposed signal detection based metric provides an image quality assessment that is complimentary to that of image RMSE. Using the two metrics in concert may yield a useful prescription for determining CT algorithm and configuration parameters when non-linear image reconstruction is used.
Among all tissue imaging modalities, photo-acoustic tomography (PAT) has been getting increasing attention in the recent past due to the fact that it has high contrast, high penetrability, and has capability of retrieving high resolution. Model-based regularized reconstruction methods used in PAT plays a crucial role in the applicability of PAT because such methods can yield high quality images from measurements obtained using fewer number of transducers. A crucial factor that determines the quality of reconstruction in such methods is the choice of regularization weight. Unfortunately, an app…
Classical total variation (TV) based iterative reconstruction algorithms assume that the signal is piecewise smooth, which causes reconstruction results to suffer from the over-smoothing effect. To address this problem, this work presents a novel computed tomography (CT) reconstruction method for the few-view problem called the group-sparsity regularization-based simultaneous algebraic reconstruction technique (GSR-SART). Group-based sparse representation, which utilizes the concept of a group as the basic unit of sparse representation instead of a patch, is introduced as the image domain prio…
Iterative image reconstruction (IIR) with sparsity-exploiting methods, such as total variation (TV) minimization, investigated in compressive sensing (CS) claim potentially large reductions in sampling requirements. Quantifying this claim for computed tomography (CT) is non-trivial, because both full sampling in the discrete-to-discrete imaging model and the reduction in sampling admitted by sparsity-exploiting methods are ill-defined. The present article proposes definitions of full sampling by introducing four sufficient-sampling conditions (SSCs). The SSCs are based on the condition number …
Multi-contrast images are commonly acquired together to maximize complementary diagnostic information, albeit at the expense of longer scan times. A time-efficient strategy to acquire high-quality multi-contrast images is to accelerate individual sequences and then reconstruct undersampled data with joint regularization terms that leverage common information across contrasts. However, these terms can cause features that are unique to a subset of contrasts to leak into the other contrasts. Such leakage-of-features may appear as artificial tissues, thereby misleading diagnosis. The goal of this …
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used to study microvascular structure and tissue perfusion. In DCE-MRI a bolus of gadolinium based contrast agent is injected into the blood stream and spatiotemporal changes induced by the contrast agent flow are estimated from a time series of MRI data. Sufficient time resolution can often only be obtained by using an imaging protocol which produces undersampled data for each image in the time series. This has led to the popularity of compressed sensing based image reconstruction approaches, where all the images in the time se…
In dynamic MRI, sufficient time resolution can often only be obtained using imaging protocols which produce undersampled data for each image in the time series. This has led to the popularity of compressed sensing (CS) based image reconstruction approaches. One of the problems in CS approaches is determining the regularization parameters, which control the balance between data fidelity the spatial and temporal regularization terms. A data-driven approach is proposed for the total variation regularization parameter selection such that the reconstructions yield expected sparsity levels in the re…
Purpose: Task-based assessment of image quality in undersampled magnetic resonance imaging provides a way of evaluating the impact of regularization on task performance. In this work, we evaluated the effect of total variation (TV) and wavelet regularization on human detection of signals with a varying background and validated a model observer in predicting human performance. Approach: Human observer studies used two-alternative forced choice (2-AFC) trials with a small signal known exactly task but with varying backgrounds for fluid-attenuated inversion recovery images reconstructed from unde…
High radiation dose in CT scans increases a lifetime risk of cancer and has become a major clinical concern. Recently, iterative reconstruction algorithms with Total Variation (TV) regularization have been developed to reconstruct CT images from highly undersampled data acquired at low mAs levels in order to reduce the imaging dose. Nonetheless, TV regularization may lead to over-smoothed images and lost edge information. To solve this problem, in this work we develop an iterative CT reconstruction algorithm with edge-preserving TV regularization to reconstruct CT images from highly undersampl…
With the development of computed tomography (CT) imaging technology, it is possible to acquire multi-energy data by spectral CT. Being different from conventional CT, the X-ray energy spectrum of spectral CT is cutting into several narrow bins which leads to the result that only a part of photon can be collected in each individual energy channel, which cause the image qualities to be severely degraded by noise and artifacts. To address this problem, we propose a spectral CT reconstruction algorithm based on low-rank representation and structure preserving regularization in this paper. To make …
This work is to develop a general framework, namely analytical iterative reconstruction (AIR) method, to incorporate analytical reconstruction (AR) method into iterative reconstruction (IR) method, for enhanced CT image quality and reconstruction efficiency. Specifically, AIR is established based on the modified proximal forward-backward splitting (PFBS) algorithm, and its connection to the filtered data fidelity with sparsity regularization is discussed. As a result, AIR decouples data fidelity and image regularization with a two-step iterative scheme, during which an AR-projection step updat…
Repeated computed tomography (CT) scans are required in some clinical applications such as image-guided radiotherapy and follow-up observations over a time period. To optimize the radiation dose utility, a normal-dose (or full-dose) CT scan is often first performed to set up reference, followed by a series of low-dose scans. Using the previous normal-dose scan to improve follow-up low-dose scans reconstruction has drawn great interests recently, such as the previous normal-dose induced nonlocal means (ndiNLM) regularization method. However, one major concern with this method is that whether it…
Regularization methods are commonly used in X-ray CT image reconstruction. Different regularization methods reflect the characterization of different prior knowledge of images. In a recent work, a new regularization method called a low-dimensional manifold model (LDMM) is investigated to characterize the low-dimensional patch manifold structure of natural images, where the manifold dimensionality characterizes structural information of an image. In this paper, we propose a CT image reconstruction method based on the prior knowledge of the low-dimensional manifold of CT image. Using the clinica…
Ultrasound computed tomography (USCT) holds great promise for breast cancer screening. Waveform inversion-based image reconstruction methods account for higher order diffraction effects and can produce high-resolution USCT images, but are computationally demanding. Recently, a source encoding technique was combined with stochastic gradient descent to greatly reduce image reconstruction times. However, this method bundles the stochastic data fidelity term with the deterministic regularization term. This limitation can be overcome by replacing stochastic gradient descent (SGD) with a structured …
This paper proposes a spatial-Radon domain CT image reconstruction model based on data-driven tight frames (SRD-DDTF). The proposed SRD-DDTF model combines the idea of joint image and Radon domain inpainting model of \cite{Dong2013X} and that of the data-driven tight frames for image denoising \cite{cai2014data}. It is different from existing models in that both CT image and its corresponding high quality projection image are reconstructed simultaneously using sparsity priors by tight frames that are adaptively learned from the data to provide optimal sparse approximations. An alternative mini…
Multi-energy CT takes advantage of the non-linearly varying attenuation properties of elemental media with respect to energy, enabling more precise material identification than single-energy CT. The increased precision comes with the cost of a higher radiation dose. A straightforward way to lower the dose is to reduce the number of projections per energy, but this makes tomographic reconstruction more ill-posed. In this paper, we propose how this problem can be overcome with a combination of a regularization method that promotes structural similarity between images at different energies and a …
Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose X-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method for various clinical tasks. According to the maximum a posterior (MAP) estimation, the SIR methods can be typically formulated by an objective function consisting of two terms: (1) data-fidelity (or equivalently, data-fitting or data-mismatch) term modeling the statistics of projection measurements, and (2) regularization (or equivalently, prior or penalty) term reflecting …
Parallel MRI is a fast imaging technique that enables the acquisition of highly resolved images in space. It relies on $k$-space undersampling and multiple receiver coils with complementary sensitivity profiles in order to reconstruct a full Field-Of-View (FOV) image. The performance of parallel imaging mainly depends on the reconstruction algorithm, which can proceed either in the original $k$-space (GRAPPA, SMASH) or in the image domain (SENSE-like methods). To improve the performance of the widely used SENSE algorithm, 2D- or slice-specific regularization in the wavelet domain has been effi…
University of Toulouse(图卢兹大学);CEA-NeuroSpin(法国原子能和替代能源委员会-NeuroSpin);University Paris-Est(巴黎东大学)
Parallel MRI is a fast imaging technique that enables the acquisition of highly resolved images in space or/and in time. The performance of parallel imaging strongly depends on the reconstruction algorithm, which can proceed either in the original k-space (GRAPPA, SMASH) or in the image domain (SENSE-like methods). To improve the performance of the widely used SENSE algorithm, 2D- or slice-specific regularization in the wavelet domain has been deeply investigated. In this paper, we extend this approach using 3D-wavelet representations in order to handle all slices together and address reconstr…
Self-Supervised k-Space Regularization for Motion-Resolved Abdominal MRI Using Neural Implicit k-Space Representation
Helmholtz Center Munich(慕尼黑亥姆霍兹中心);Technical University of Munich(慕尼黑工业大学);Imperial College London(伦敦帝国学院);Millenium Institute for Intelligent Healthcare Engineering(千禧智能医疗工程研究所);Pontificia Universidad Católica de Chile(智利天主教大学);King’s College London(伦敦国王学院)
Recent years have seen growing interest in exploiting dual- and multi-energy measurements in computed tomography (CT) in order to characterize material properties as well as object shape. Material characterization is performed by decomposing the scene into constitutive basis functions, such as Compton scatter and photoelectric absorption functions. While well motivated physically, the joint recovery of the spatial distribution of photoelectric and Compton properties is severely complicated by the fact that the data are several orders of magnitude more sensitive to Compton scatter coefficients …
An automatic regularization method: An application for 3D X-ray micro-CT reconstruction using sparse data
University of Helsinki(赫尔辛基大学);Universitas Gadjah Mada(加查马达大学);Infotech Oulu, University of Oulu(奥卢大学英福泰克奥卢中心);University of Oulu(奥卢大学);University of Eastern Finland(芬兰东部大学);Oulu University Hospital(奥卢大学医院)
Nonperiodic dynamic CT reconstruction using backward-warping INR with regularization of diffeomorphism (BIRD)
Department of Engineering Physics, Tsinghua University(清华大学工程物理系);Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua Medicine, Tsinghua University(北京清华长庚医院放射科,清华大学临床医学院,清华大学医学院,清华大学);United Imaging Healthcare, North America(联合影像(北美));Shanghai United Imaging Healthcare Co., Ltd.(上海联合影像医疗科技有限公司)
Diffusion MRI is a well established imaging modality providing a powerful way to probe the structure of the white matter non-invasively. Despite its potential, the intrinsic long scan times of these sequences have hampered their use in clinical practice. For this reason, a large variety of methods have been recently proposed to shorten the acquisition times. Among them, spherical deconvolution approaches have gained a lot of interest for their ability to reliably recover the intra-voxel fiber configuration with a relatively small number of data samples. To overcome the intrinsic instabilities …