In dynamic MRI, sufficient time resolution can often only be obtained using imaging protocols which produce undersampled data for each image in the time series. This has led to the popularity of compressed sensing (CS) based image reconstruction approaches. One of the problems in CS approaches is determining the regularization parameters, which control the balance between data fidelity the spatial and temporal regularization terms. A data-driven approach is proposed for the total variation regularization parameter selection such that the reconstructions yield expected sparsity levels in the regularization domains. The expected sparsity levels are obtained from the measurement data for the temporal regularization and from a reference image for the spatial regularization. Two formulations are proposed. The first is a 2D search for a parameter pair which produces expected sparsity in both the temporal and spatial regularization domains. In the second approach, the sparsity-based parameter selection is split to two 1D searches using the S-curve method. The approaches are evaluated using simulated and experimental DCE-MRI. In the simulated test case, both proposed methods produce a parameter pair that is close to the RMSE optimal pair, and the reconstruction error is also close to minimum. In the experimental test case, the methods produce almost similar parameter selection, and the reconstructions are of high perceived quality. Both approaches lead to a highly feasible selection of the temporal and spatial regularization parameters in both the simulated and experimental test cases while the sequential method is computationally more efficient.
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used to study microvascular structure and tissue perfusion. In DCE-MRI a bolus of gadolinium based contrast agent is injected into the blood stream and spatiotemporal changes induced by the contrast agent flow are estimated from a time series of MRI data. Sufficient time resolution can often only be obtained by using an imaging protocol which produces undersampled data for each image in the time series. This has led to the popularity of compressed sensing based image reconstruction approaches, where all the images in the time se…
Purpose: Task-based assessment of image quality in undersampled magnetic resonance imaging provides a way of evaluating the impact of regularization on task performance. In this work, we evaluated the effect of total variation (TV) and wavelet regularization on human detection of signals with a varying background and validated a model observer in predicting human performance. Approach: Human observer studies used two-alternative forced choice (2-AFC) trials with a small signal known exactly task but with varying backgrounds for fluid-attenuated inversion recovery images reconstructed from unde…
Multi-contrast images are commonly acquired together to maximize complementary diagnostic information, albeit at the expense of longer scan times. A time-efficient strategy to acquire high-quality multi-contrast images is to accelerate individual sequences and then reconstruct undersampled data with joint regularization terms that leverage common information across contrasts. However, these terms can cause features that are unique to a subset of contrasts to leak into the other contrasts. Such leakage-of-features may appear as artificial tissues, thereby misleading diagnosis. The goal of this …
Self-Supervised k-Space Regularization for Motion-Resolved Abdominal MRI Using Neural Implicit k-Space Representation
Helmholtz Center Munich(慕尼黑亥姆霍兹中心);Technical University of Munich(慕尼黑工业大学);Imperial College London(伦敦帝国学院);Millenium Institute for Intelligent Healthcare Engineering(千禧智能医疗工程研究所);Pontificia Universidad Católica de Chile(智利天主教大学);King’s College London(伦敦国王学院)
University of Toulouse(图卢兹大学);CEA-NeuroSpin(法国原子能和替代能源委员会-NeuroSpin);University Paris-Est(巴黎东大学)
Parallel MRI is a fast imaging technique that enables the acquisition of highly resolved images in space or/and in time. The performance of parallel imaging strongly depends on the reconstruction algorithm, which can proceed either in the original k-space (GRAPPA, SMASH) or in the image domain (SENSE-like methods). To improve the performance of the widely used SENSE algorithm, 2D- or slice-specific regularization in the wavelet domain has been deeply investigated. In this paper, we extend this approach using 3D-wavelet representations in order to handle all slices together and address reconstr…
Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on the methodology used to combine multichannel signals. Indeed, the two prevailing methods for multichannel signal combination lead to Rician and noncentral Chi noise distributions. Here we develop a Robust and Unbiased Model-BAsed Spherical Deconvolution (RUMBA-SD) technique, intended to dea…
Parallel MRI is a fast imaging technique that enables the acquisition of highly resolved images in space. It relies on $k$-space undersampling and multiple receiver coils with complementary sensitivity profiles in order to reconstruct a full Field-Of-View (FOV) image. The performance of parallel imaging mainly depends on the reconstruction algorithm, which can proceed either in the original $k$-space (GRAPPA, SMASH) or in the image domain (SENSE-like methods). To improve the performance of the widely used SENSE algorithm, 2D- or slice-specific regularization in the wavelet domain has been effi…
PISCO: Self-Supervised k-Space Regularization for Improved Neural Implicit k-Space Representations of Dynamic MRI
Helmholtz Munich(亥姆霍兹慕尼黑中心);Technical University of Munich(慕尼黑工业大学);Klinikum rechts der Isar(右岸医院(慕尼黑工业大学附属));Imperial College London(帝国理工学院);Pontificia Universidad Católica de Chile(智利天主教大学);King’s College London(伦敦国王学院)
Real-time magnetic resonance imaging (MRI) poses unique challenges related to the speed of data acquisition and to the degree of undersampling necessary to achieve this speed. This Master's thesis introduces and evaluates two pre-processing approaches for these problems: Coil compression to reduce the data volume and a channel selection algorithm to reduce streak artifacts which arise as a consequence of undersampling. Both approaches are tested on real data covering anatomical imaging of the head and of the heart.
We develop a Bayesian nonparametric model for reconstructing magnetic resonance images (MRI) from highly undersampled k-space data. We perform dictionary learning as part of the image reconstruction process. To this end, we use the beta process as a nonparametric dictionary learning prior for representing an image patch as a sparse combination of dictionary elements. The size of the dictionary and the patch-specific sparsity pattern are inferred from the data, in addition to other dictionary learning variables. Dictionary learning is performed directly on the compressed image, and so is tailor…
Weight-Guided Constraints for Body Model and Lead Selection in Pediatric CIED MRI Safety Simulations
Northwestern University(西北大学);Feinberg School of Medicine, Northwestern University(西北大学芬伯格医学院);Ann & Robert H. Lurie Children’s Hospital(安和罗伯特·H·卢里儿童医院)
Inverse problems for accelerated MRI typically incorporate domain-specific knowledge about the forward encoding operator in a regularized reconstruction framework. Recently physics-driven deep learning (DL) methods have been proposed to use neural networks for data-driven regularization. These methods unroll iterative optimization algorithms to solve the inverse problem objective function, by alternating between domain-specific data consistency and data-driven regularization via neural networks. The whole unrolled network is then trained end-to-end to learn the parameters of the network. Due t…
Spatiotemporal implicit neural representation for unsupervised dynamic MRI reconstruction
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China(上海交通大学生物医学工程学院);School of Information Science and Technology, ShanghaiTech University, Shanghai, China(上海科技大学信息科学与技术学院);iHuman Institute, Shanghaitech University, Shanghai, China(上海科技大学iHuman研究所)
The compressed sensing (CS) framework leverages the sparsity of MR images to reconstruct from undersampled acquisitions. CS reconstructions involve one or more regularization parameters that weigh sparsity in transform domains against fidelity to acquired data. While parameter selection is critical for reconstruction quality, the optimal parameters are subject and dataset specific. Thus, commonly practiced heuristic parameter selection generalizes poorly to independent datasets. Recent studies have proposed to tune parameters by estimating the risk of removing significant image coefficients. L…
Diffusion MRI requires sufficient coverage of the diffusion wavevector space, also known as the q-space, to adequately capture the pattern of water diffusion in various directions and scales. As a result, the acquisition time can be prohibitive for individuals who are unable to stay still in the scanner for an extensive period of time, such as infants. To address this problem, in this paper we harness non-local self-similar information in the x-q space of diffusion MRI data for q-space upsampling. Specifically, we first perform neighborhood matching to establish the relationships of signals in…
University of Minnesota(明尼苏达大学);Sungkyunkwan University(成均馆大学)
Recent studies show that deep learning (DL) based MRI reconstruction outperforms conventional methods, such as parallel imaging and compressed sensing (CS), in multiple applications. Unlike CS that is typically implemented with pre-determined linear representations for regularization, DL inherently uses a non-linear representation learned from a large database. Another line of work uses transform learning (TL) to bridge the gap between these two approaches by learning linear representations from data. In this work, we combine ideas from CS, TL and DL reconstructions to learn deep linear convol…
GE Global Research Center(GE全球研究中心);Technische Universität München(慕尼黑工业大学);INSERM(法国国家健康与医学研究院);Université de Lorraine(洛林大学);GE Healthcare(GE医疗)
To develop an efficient motion-compensated reconstruction technique for free-breathing cardiac magnetic resonance imaging (MRI) that allows high-quality images to be reconstructed from multiple undersampled single-shot acquisitions. The proposed method is a joint image reconstruction and motion correction method consisting of several steps, including a non-rigid motion extraction and a motion-compensated reconstruction. The reconstruction includes a denoising with the Beltrami regularization, which offers an ideal compromise between feature preservation and staircasing reduction. Results were …