arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2009.09997astro-ph.IMphysics.ins-det
收藏

BICEP阵列项目的亚开尔文冷却

Sub-Kelvin Cooling for the BICEP Array Project

Lionel Duband, Thomas Prouve, James Bock, Lorenzo Moncelsi, Alessandro Schillaci

摘要:

在天体物理学领域,来自遥远星系和其他暗淡宇宙源的毫米和亚毫米波长的微弱信号需要使用高灵敏度实验。低温技术和使用低温探测器对实现科学目标至关重要,可以降低探测器噪声水平,提高仪器稳定性。测辐射热探测器通常被冷却到1 K以下的温度,无论实验是天基平台还是地基望远镜,对仪器的限制都很严格。后者通常部署在偏远和恶劣的环境中,如南极,需要保持最低限度的维护。CEA-SBT在无振动多级氦吸附冷却器的开发方面拥有强大的传统,当安装在温度<5 K的冷台上时,该冷却器可以提供低至200 mK的冷却。在本文中,我们专注于一个三级冷却器的发展,致力于由加州理工学院/喷气推进实验室领导的BICEP阵列项目,该项目旨在研究宇宙的诞生,特别是独特的B模式模式印记的原始引力波的偏振的宇宙微波背景。几个低温接收器正在开发中,每个都有一个这样的氦吸附冷却器,从一个由Cryomech脉冲管冷却的4K级运行,在4.2K时热升>1.35W,在45 K时热升> 36 W。该项目的主要挑战是要冷却到亚开尔文温度(250 mK时为26 kg)的大质量以及由此产生的长冷却时间,在这种新颖的冷却器设计中,通过在不同温度阶段之间实施被动和主动热链接,将冷却时间保持在最低限度。第一个单元的大小分别为2.8K、340和250 mK的最高温度下提供230、70和2μW的净热升,最短持续时间为48小时。

英文摘要:

In the field of astrophysics, the faint signal from distant galaxies and other dim cosmological sources at millimeter and submillimeter wavelengths require the use of high-sensitivity experiments. Cryogenics and the use of low-temperature detectors are essential to the accomplishment of the scientific objectives, allowing lower detector noise levels and improved instrument stability. Bolometric detectors are usually cooled to temperatures below 1K, and the constraints on the instrument are stringent, whether the experiment is a space-based platform or a ground-based telescope. The latter are usually deployed in remote and harsh environments such as the South Pole, where maintenance needs to be kept minimal. CEA-SBT has acquired a strong heritage in the development of vibration-free multistage helium-sorption coolers, which can provide cooling down to 200 mK when mounted on a cold stage at temperatures <5K. In this paper, we focus on the development of a three-stage cooler dedicated to the BICEP Array project led by Caltech/JPL, which aims to study the birth of the Universe and specifically the unique B-mode pattern imprinted by primordial gravitational waves on the polarization of the Cosmic Microwave Background. Several cryogenic receivers are being developed, each featuring one such helium-sorption cooler operated from a 4K stage cooled by a Cryomech pulse-tube with heat lifts of >1.35W at 4.2K and >36W at 45K. The major challenge of this project is the large masses to be cooled to sub-kelvin temperatures (26 kg at 250mK) and the resulting long cool-down time, which in this novel cooler design is kept to a minimum with the implementation of passive and active thermal links between different temperature stages. A first unit has been sized to provide 230, 70 and 2μW of net heat lifts at the maximum temperatures of 2.8K, 340 and 250mK, respectively, for a minimum duration of 48 hours.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑