摘要:

扫描透射电子显微镜(STEM)的仪器性能取决于入射电子探针的尺寸和形状。实现最佳探头轮廓的最重要的光学因素是探头形成孔径的半径,其确定照明的会聚半角。然而,经常被忽视的是,偏离这个最佳值的小偏差会降低图像对比度的分辨率和可解释性。孔径半径的30%误差会导致典型晶格间距的对比度降低2倍,以及薄层(如栅极氧化物)厚度测量的5倍误差。理论计算的最佳会聚角,从波光学考虑的探头形成的条件,解释和讨论其后果。然后介绍了一种测量和调节会聚角的实验方法。这适用于未校正的电子显微镜。对于校正的仪器,Cs=0,并且Cc通常确定孔径的选择-参见例如ULTRAMICROSCOPY 108,(2008)1454-1466

英文摘要:

The achievable instrumental performance of a scanning transmission electron microscope (STEM) is determined by the size and shape of the incident electron probe. The most important optical factor in achieving the optimum probe profile is the radius of the probe-forming aperture, which determines the convergence semi-angle of the illumination. What is often overlooked however is that small deviations from this optimum can degrade both the resolution and interpretability of image contrast. A 30% error in aperture radius can lead to a factor of 2 contrast reduction in typical lattice spacings, and a 5 Å error in the thickness measurement of thin layers (such as gate oxides). Theoretical calculations of the optimum convergence angles, from a wave-optical consideration of the probe forming conditions, are explained and their consequences discussed. An experimental approach to the measurement and tuning of the convergence angle is then introduced. This is intended for uncorrected electron microscopes. For corrected instruments, Cs=0, and Cc usually determines the choice of aperture - see e.g. ULTRAMICROSCOPY 108, (2008) 1454-1466