Timing performance of the LHCb VELO Timepix3 Telescope
K. Heijhoff, K. Akiba, M. van Beuzekom, P. Bosch, J. Buytaert, M. Campbell, A. P. Colijn, P. Collins, E. Dall'Occo, T. Evans, R. Geertsema, M. L. E. Heidotting,… 展开作者
K. Heijhoff, K. Akiba, M. van Beuzekom, P. Bosch, J. Buytaert, M. Campbell, A. P. Colijn, P. Collins, E. Dall'Occo, T. Evans, R. Geertsema, M. L. E. Heidotting, D. Hynds, X. Llopart Cudie, H. Schindler, H. Snoek
We performed a detailed study of the timing performance of the LHCb VELO Timepix3 Telescope with a 180 GeV/c mixed hadron beam at the CERN SPS. A twofold method was developed to improve the resolution of single-plane time measurements, resulting in a more precise overall track time measurement. The first step uses spatial information of reconstructed tracks in combination with the measured signal charge in the sensor to correct for a mixture of different effects: variations in charge carrier drift time; variations in signal induction, which are the result of a non-uniform weighting field in the pixels; and lastly, timewalk in the analog front-end. The second step corrects for systematic timing offsets in Timepix3 that vary from -2 ns to 2 ns. By applying this method, we improved the track time resolution from 438$\,\pm\,$16 ps to 276$\,\pm\,$4 ps.
The Ring-Imaging Cherenkov (RICH) detectors at LHCb have an intrinsic time resolution of better than 10 ps owing to the prompt Cherenkov radiation and focusing mirrors optics. While only spatial information has been used in the experiment to date, the addition of photon time information is one of the cornerstones of the future RICH upgrade programme. The novel timing techniques provide a powerful tool for background suppression and particle ID performance improvements. Here, developments to implement fast-timing in the front-end electronics are presented.
In 2019, the LHCb experiment at CERN will undergo a major upgrade where its detector electronics and the entire readout system will be replaced. The goal is to read-out all events at the full LHC frequency of 40 MHz, reaching a total data rate of ~40 Tb/s. In this context, a new timing, trigger and readout control system has been developed: its main tasks are to distribute centrally the clock, the timing information and to synchronize all elements in the readout system: from the very last Front-End ASIC to the building of events to be stored. The heart of the timing and readout control system …
The LHCb Vertex Locator contains 42 silicon sensor modules. Each module has two silicon sensors. A method for determining the relative alignment of the silicon sensors within each module from data is presented. The software implementation details are discussed. Monte-Carlo simulation studies are described that demonstrate an alignment precision of 1.3 micron is obtained in the sensor plane.
The upgraded CERN LHCb detector, due to start data taking in 2021, will have to reconstruct 4 TB/s of raw detector data in real time using commodity processors. This is one of the biggest real-time data processing challenges in any scientific domain. We present an intrinsically parallel reconstruction algorithm for the vertex detector of the LHCb experiment designed to optimally exploit multi-core general purpose architectures. We compare it to previous state-of-the-art scalar pattern recognition algorithms and show significantly faster processing and in some cases increased physics performanc…
The LHCb VELO Timepix3 telescope is a silicon pixel tracking system constructed initially to evaluate the performance of LHCb VELO Upgrade prototypes. The telesope consists of eight hybrid pixel silicon sensor planes equipped with the Timepix3 ASIC. The planes provide excellent charge measurement, timestamping and spatial resolution and the system can function at high track rates. This paper describes the construction of the telescope and its data acquisition system and offline reconstruction software. A timing resolution of 350~ps was obtained for reconstructed tracks. A pointing resolution o…
A comprehensive study of the spatial resolution and detection efficiency of sensor prototypes developed for the LHCb VELO upgrade is presented. Data samples were collected at the CERN SPS H8 beam line using a hadron mixture of protons and pions with momenta of approximately 180 GeV/c. The sensor performance was characterised using both irradiated and non-irradiated sensors. Irradiated samples were subjected to a maximum fluence of $\mathrm{8\times10^{15}~1~MeV~n_{eq}~cm^{-2}}$, of both protons and neutrons. The spatial resolution is measured comparing the detected hits to the position as predi…
LHCb will commence data taking as the first dedicated heavy flavour experiment at a hadron collider in 2008. A very high hit precision from its vertex detector (VELO) is essential to meet the tight requirements of vertex reconstruction in B-physics. The single hit precision of the VELO is better than 10 micron. However, the VELO is operated only 8 mm from the beam and must be retracted and reinserted each LHC fill. Hence, the detector places unique demands on its alignment algorithm. The partially assembled VELO system has already been tested in a beam test. The novel software alignment method…
An extensive sensor testing campaign is presented, dedicated to measuring the charge collection properties of prototype candidates for the Vertex Locator (VELO) detector for the upgraded LHCb experiment. The charge collection is measured with sensors exposed to fluences of up to $8 \times 10^{15}~1~\mathrm{\,Me\kern -0.1em V}~ \mathrm{ \,n_{eq}}~{\mathrm{ \,cm}}^{-2}$, as well as with nonirradiated prototypes. The results are discussed, including the influence of different levels of irradiation and bias voltage on the charge collection properties. Charge multiplication is observed on some sens…
The thermal properties of the LHCb Vertex Locator (VELO) are studied using the real-time detector alignment procedure. The variation of the position and orientation of the detector elements as a function of the operating temperature of the VELO is presented. This study uses a dataset collected by the LHCb experiment during a VELO temperature scan performed at the end of LHC Run 2 (October 2018). Significant shrinkage of the VELO modules is observed at the operating temperature of $-30^\circ$ compared to the laboratory measurements on a single module taken at a range of temperatures from $+45^\…
We describe the Hybrid seeding, a standalone pattern recognition algorithm aiming at finding charged particle trajectories for the LHCb upgrade. A significant improvement to the charged particle reconstruction efficiency is accomplished by exploiting the knowledge of the LHCb magnetic field and the position of energy deposits in the scintillating fibre tracker detector. Moreover, we achieve a low fake rate and a small contribution to the overall timing budget of the LHCb real-time data processing.
LHCb is a forward spectrometer experiment dedicated to the study of new physics in the decays of beauty and charm hadrons produced in proton collisions at the Large Hadron Collider (LHC) at CERN. The VErtex LOcator (VELO) is the microstrip silicon detector surrounding the interaction point, providing tracking and vertexing measurements. The upgrade of the LHCb experiment, planned for 2018, will increase the luminosity up to $\rm 2\times10^{33}\ cm^{-2}s^{-1}$ and will perform the readout as a trigger-less system with an event rate of 40 MHz. Extremely non-uniform radiation doses will reach up …
The upgrade of the LHCb experiment, scheduled for LHC Run-III, scheduled to start in 2021, will transform the experiment to a trigger-less system reading out the full detector at 40 MHz event rate. All data reduction algorithms will be executed in a high-level software farm enabling the detector to run at luminosities of $2\times10^{33} \mathrm{cm}^{-2}\mathrm{s}^{-1}$. The Vertex Locator (VELO) is the silicon vertex detector surrounding the interaction region. The current detector will be replaced with a hybrid pixel system equipped with electronics capable of reading out at 40 MHz. The upgra…
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in combination with the five-fold increase in luminosity, requires radical changes to LHCb's electronics, and, in some cases, the replacement of entire sub-detectors with state-of-the-art detector techno…
LHCb is the dedicated heavy flavour experiment at the Large Hadron Collider at CERN. The partially assembled silicon vertex locator (VELO) of the LHCb experiment has been tested in a beam test. The data from this beam test have been used to determine the performance of the VELO alignment algorithm. The relative alignment of the two silicon sensors in a module and the relative alignment of the modules has been extracted. This alignment is shown to be accurate at a level of approximately 2 micron and 0.1 mrad for translations and rotations, respectively in the plane of the sensors. A single hit …
The LHCb VELO Upgrade I, currently being installed for the 2022 start of LHC Run 3, uses silicon microchannel coolers with internally circulating bi-phase \cotwo for thermal control of hybrid pixel modules operating in vacuum. This is the largest scale application of this technology to date. Production of the microchannel coolers was completed in July 2019 and the assembly into cooling structures was completed in September 2021. This paper describes the R\&D path supporting the microchannel production and assembly and the motivation for the design choices. The microchannel coolers have excelle…
After a highly successful first data taking period at the LHC, the LHCb experiment developed a new trigger strategy with a real-time reconstruction, alignment and calibration for Run II. This strategy relies on offline-like track reconstruction in the high level trigger, making a separate offline event reconstruction unnecessary. To enable such reconstruction, and additionally keeping up with a higher event rate due to the accelerator upgrade, the time used by the track reconstruction had to be decreased. Timing improvements have in parts been achieved by utilizing parallel computing technique…
LHCb is one of the four main experiments of the Large Hadron Collider (LHC) project, which will start at CERN in 2008. The experiment is primarily dedicated to B-Physics and hence requires precise vertex reconstruction. The silicon vertex locator (VELO) has a single hit precision of better than 10 micron and is used both off-line and in the trigger. These requirements place strict constraints on its alignment. Additional challenges for the alignment arise from the detector being retracted between each fill of the LHC and from its unique circular disc r/phi strip geometry. This paper describes …
LHCb is an experiment dedicated to the study of new physics in the decays of beauty and charm hadrons at the Large Hadron Collider (LHC) at CERN. The Vertex Locator (VELO) is the silicon detector surrounding the LHCb interaction point. The detector operates in a severe and highly non-uniform radiation environment. The small pitch and analogue readout result in a best single hit precision of 4 $\rm μ$m. The upgrade of the LHCb experiment, planned for 2018, will transform the entire readout to a trigger-less system operating at 40 MHz event rate. The vertex detector will have to cope with radiat…
The LHCb experiment at CERN is currently completing its first big data taking campaign at the LHC started in 2009. It has been collecting data at more than 2.5 times its nominal design luminosity value and with a global efficiency of ~92%. Even more striking, the efficiency between online and offline recorded luminosity, obtained by comparing the data quality output, is close to 99%, which highlights how well the detector, its data acquisition system and its control system have been performing despite much harsher and more variable conditions than initially foreseen. In this paper, the excelle…
We demonstrate a coincidence velocity map imaging apparatus equipped with a novel time stamping fast optical camera, Tpx3Cam, whose high sensitivity and ns timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.
The LHCb Outer Tracker is a gaseous detector covering an area of $5\times 6 m^2$ with 12 double layers of straw tubes. The performance of the detector is presented based on data of the LHC Run 2 running period from 2015 and 2016. Occupancies and operational experience for data collected in $p p$, pPb and PbPb collisions are described. An updated study of the ageing effects is presented showing no signs of gain deterioration or other radiation damage effects. In addition several improvements with respect to LHC Run 1 data taking are introduced. A novel real-time calibration of the time-alignmen…
Precise knowledge of the location of the material in the LHCb vertex locator (VELO) is essential to reducing background in searches for long-lived exotic particles, and in identifying jets that originate from beauty and charm quarks. Secondary interactions of hadrons produced in beam-gas collisions are used to map the location of material in the VELO. Using this material map, along with properties of a reconstructed secondary vertex and its constituent tracks, a $p$-value can be assigned to the hypothesis that the secondary vertex originates from a material interaction. A validation of this pr…
A significant upgrade of the LHCb detector is scheduled to be installed in 2018-2019. Afterwards all sub-detectors will be read out at the LHC bunch crossing frequency of 40 MHz and the trigger will be fully implemented in software. The silicon strip vertex detector will be replaced by a hybrid pixel detector. In these proceedings the following items are discussed: frontend ASIC, data rates, data transmission, cooling, radiation hard sensors, module design and simulated performance.
A FPGA-based architecture for real-time cluster finding in the LHCb silicon pixel detector
INFN Sezione di Pisa(意大利国家核物理研究所比萨分部);Scuola Normale Superiore(比萨高等师范学校);Università di Pisa(比萨大学);Università degli Studi di Padova(帕多瓦大学);Liverpool University(利物浦大学);University of Oxford(牛津大学);Instituto Galego de Física de Altas Enerxías (IGFAE)(加利西亚高能物理研究所(IGFAE));Universidade de Santiago de Compostela(圣地亚哥德孔波斯特拉大学)
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately $\rm{45 \times 10^{12}\,1\,MeV}$ neutron equivalent ($\rm{1\,MeV\,n_{eq}}$). At the operational sensor temperature of approximately $-7\,^{\circ}\rm{C}$, the average rate of sensor current increase is $18\,\upmu\rm{A}$ per $\rm{fb^{-1}}$, in excellent agreement with predictions. The si…
The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations based on GARFIELD++ reproduce the experimental PICOSEC timing characteristics. This agreement is exploited to identify the microscopic physical variables, which determine the observed timing properties.…
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented…
The TORCH time-of-flight detector is designed to provide a 15 ps timing resolution for charged particles, resulting in $π$/$K$ particle identification up to 10 GeV/c momentum over a 10 m flight path. Cherenkov photons, produced in a quartz plate of 10 mm thickness, are focused onto an array of micro-channel plate photomultipliers (MCP-PMTs) which measure the photon arrival times and spatial positions. A half-scale ($660\times1250\times10$ mm$^3$) TORCH demonstrator module has been tested in an 8 GeV/c mixed proton-pion beam at CERN. Customised square MCP-PMTs of active area $53\times53$ mm$^2$…
Since 2017, the LHCSpin study group is investigating the installation of a HERMES-type polarized gas target (PGT) in front of the LHCb detector in order to perform Single-Spin Transverse Asymmetry (SSTA) measurements. In cooperation with LHC experts, the conditions for applying a PGT are being studied. As a viable option, a cold openable storage cell is considered. A key role for avoiding instabilities of the 7 TeV proton beam is the choice of a proper coating and the suppression of wake fields. A first warm (300 K) test storage cell is planned for installation in 2019 inside the VELO vessel, …