Image reconstruction from computed tomography (CT) measurement is a challenging statistical inverse problem since a high-dimensional conditional distribution needs to be estimated. Based on training data obtained from high-quality reconstructions, we aim to learn a conditional density of images from noisy low-dose CT measurements. To tackle this problem, we propose a hybrid conditional normalizing flow, which integrates the physical model by using the filtered back-projection as conditioner. We evaluate our approach on a low-dose CT benchmark and demonstrate superior performance in terms of structural similarity of our flow-based method compared to other deep learning based approaches.
Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing Flows
School of Mathematical Sciences, Capital Normal University(首都师范大学数学学院);Centre for Mathematical Imaging Techniques, University of Liverpool(利物浦大学数学成像技术中心);Department of Mathematics and Statistics, University of Strathclyde(斯特拉思克莱德大学数学与统计学系)
Physics-/Model-Based and Data-Driven Methods for Low-Dose Computed Tomography: A survey
Sichuan University(四川大学);Fudan University(复旦大学);Shanghai Center for Brain Science and Brain-Inspired Technology(上海脑科学与类脑研究中心);Rensselaer Polytechnic Institute(伦斯勒理工学院)
X2CT-FLOW: Maximum a posteriori reconstruction using a progressive flow-based deep generative model for ultra sparse-view computed tomography in ultra low-dose protocols
The University of Tokyo Hospital(东京大学医学部附属医院);Center for Frontier Medical Engineering, Chiba University(千叶大学前沿医疗工程中心);Division of Radiology and Biomedical Engineering, Graduate School of Medicine, The University of Tokyo(东京大学医学研究生院放射科与生物医学工程学系)
Enhancing Low Dose Computed Tomography Images Using Consistency Training Techniques
University of Kentucky(肯塔基大学);Institute for Biomedical Informatics(生物医学信息学研究所);Rensselaer Polytechnic Institute(伦斯勒理工学院);University of Alabama at Birmingham(阿拉巴马大学伯明翰分校)
GAN-Based Architecture for Low-dose Computed Tomography Imaging Denoising
College of Life Science and Technology, Huazhong University of Science and Technology(华中科技大学生命科学技术学院);New York University Shanghai(上海纽约大学);School of Life Sciences and Biotechnology, Shanghai Jiao Tong University(上海交通大学生命科学技术学院)
DeepVox and SAVE-CT: a contrast- and dose-independent 3D deep learning approach for thoracic aorta segmentation and aneurysm prediction using computed tomography scans
Albert Einstein Israeli Institute of Education and Research(阿尔伯特·爱因斯坦以色列教育与研究学院);Health Innovation Techcenter(健康创新技术中心);Department of Radiology(放射科);Department of Vascular and Endovascular Surgery(血管与血管外科)
本研究提出 DeepVox 分割模型和 SAVE-CT 分类模型,在独立于对比剂和剂量的 3D CT 扫描上实现全自动胸主动脉瘤筛查,分割和分类测试集表现优异,有望降低死亡率并优化放射科评估队列。
3D unsupervised anomaly detection and localization through virtual multi-view projection and reconstruction: Clinical validation on low-dose chest computed tomography
Samsung Medical Center(三星医疗中心);Sungkyunkwan University School of Medicine(成均馆大学医学院);Sungkyunkwan University(成均馆大学)
Combining Deep Learning and Adaptive Sparse Modeling for Low-dose CT Reconstruction
传统的基于模型的图像重建(MBIR)方法将前向模型和噪声模型与简单的对象先验相结合。最近深度学习方法在图像重建中的应用提供了一种成功的数据驱动方法,可以解决在测量欠采样或各种类型噪声的情况下重建图像时面临的挑战。在这项工作中,我们提出了一个混合监督-无监督学习框架的X射线计算机断层扫描(CT)图像重建。所提出的学习公式利用稀疏或无监督学习的先验知识和神经网络重构器来模拟定点迭代过程。每个建议的训练块由确定性MBIR求解器和神经网络组成。信息并行地流过这两个重构器,然后被最佳地组合,并且多个这样的块被级联以形成重构流水线。我们证明了这种学习的混合模型在训练数据有限的情况下用于低剂量CT图像重建的有效性,其中我们使用NIH AAPM Mayo Clinic低剂量CT Grand Challenge数据集进行训练和测试。在我们的实验中,我们研究了有监督的深度网络重构器和基于稀疏表示(无监督)的学习或分析先验的组合。我们的研究结果表明,所提出的框架相比,最近的重建方法有前途的性能。
Ultra Low-Parameter Denoising: Trainable Bilateral Filter Layers in Computed Tomography
Friedrich-Alexander University Erlangen-Nürnberg(埃尔朗根-纽伦堡弗里德里希-亚历山大大学);Fraunhofer Institute for Ceramic Technologies and Systems IKTS(弗劳恩霍夫陶瓷技术与系统研究所(IKTS));Leibniz Institute for Analytical Sciences ISAS(莱布尼茨分析科学研究所(ISAS));University Hospital Erlangen(埃尔朗根大学医院);Institute for Nanotechnology and Correlative Microscopy e.V. INAM(纳米技术与关联显微镜协会研究所(INAM))
计算机断层扫描被广泛用作一种成像工具,以显示具有表达性骨-软组织对比度的三维结构。然而,CT分辨率和辐射剂量是紧密纠缠在一起的,突出了低剂量CT与复杂的去噪算法相结合的重要性。大多数数据驱动的去噪技术都基于深度神经网络,因此包含数十万个可训练的参数,这使得它们难以理解,并且容易出现预测失败。开发可理解且强大的去噪算法,实现最先进的性能,有助于在保持数据完整性的同时最大限度地减少辐射剂量。本文提出了一种基于双边滤波思想的开放源代码CT去噪框架。我们提出了一种双边滤波器,可以将其纳入深度学习管道,并通过计算其超参数及其输入的梯度流以纯粹的数据驱动方式进行优化。在纯图像到图像的管道和跨不同的域,如原始探测器数据和重建的体积,使用可微反投影层,去噪,证明。虽然每个滤波器层仅使用三个空间参数和一个范围参数,但所提出的去噪管道可以与具有数十万个参数的深度最先进的去噪架构竞争。在SSIM和PSNR方面,在X射线显微镜骨骼数据(0.7053和33.10)和2016年低剂量CT Grand Challenge数据集(0.9674和43.07)上实现了具有竞争力的去噪性能。由于具有明确效果的可训练参数数量极低,与大多数其他基于深度学习的去噪架构相比,在拟议的管道中随时保证预测可靠性和数据完整性。
WIA-LD2ND: Wavelet-based Image Alignment for Self-supervised Low-Dose CT Denoising
School of Computer Science, Wuhan University(武汉大学计算机学院);School of Computer Science, Central China Normal University(华中师范大学计算机学院);University of Louisville(路易斯维尔大学)
Low-Dose 3D Bonding Mapping Through "Soft" Core-Loss EELS Tomography and Unsupervised Deep Learning
Université de Lille(里尔大学);Instituto de Nanociencia y Materiales de Aragon (INMA), CSIC-U. de Zaragoza(阿拉贡纳米科学与材料研究所(INMA),萨拉戈萨大学/西班牙国家研究委员会);Univ. Grenoble Alpes, CEA, Leti(格勒诺布尔阿尔卑斯大学,法国原子能和替代能源委员会,技术研究所);Centre d’Elaboration de Matériaux et d’Etudes Structurales (CEMES), University of Toulouse and CNRS(材料与结构研究制备中心(CEMES),图卢兹大学及法国国家科学研究中心);Univ. Lille, FR 2638-IMEC-Institut Michel-Eugène Chevreul(里尔大学,FR 2638-IMEC-米歇尔·欧仁·谢弗勒尔研究所);CEA, Joliot, NeuroSpin(法国原子能和替代能源委员会,若利奥神经影像中心);Inria, MIND, Université Paris-Saclay(法国国家信息与自动化研究所,MIND团队,巴黎萨克雷大学);Department of Inorganic and Organic Chemistry, Inorganic Chemistry Section, University of Barcelona(巴塞罗那大学无机与有机化学系,无机化学教研室);Institute of Nanoscience and Nanotechnology (IN2UB), Universitat de Barcelona(巴塞罗那大学纳米科学与纳米技术研究所(IN2UB));Department of Materials Science and Engineering, Ångström Laboratory, Uppsala University(乌普萨拉大学昂斯特实验室材料科学与工程系);LENS-MIND, Departament d'Enginyeria Electrònica i Biomèdica, Universitat de Barcelona(巴塞罗那大学电子与生物医学工程系,LENS-MIND);Laboratorio de Microscopias Avanzadas, Universidad de Zaragoza(萨拉戈萨大学先进显微术实验室)
Two-Phase Multi-Dose-Level PET Image Reconstruction with Dose Level Awareness
School of Computer Science, Sichuan University(四川大学计算机学院);School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University(上海科技大学生物医学工程学院 & 先进医学材料与器件国家重点实验室);Shanghai United Imaging Intelligence Co., Ltd.(上海联影智能医疗科技有限公司)
Amortized Normalizing Flows for Transcranial Ultrasound with Uncertainty Quantification
Georgia Institute of Technology(佐治亚理工学院);Rice University(莱斯大学);University Medical Center Utrecht(乌得勒支大学医学中心);Centrum Wiskunde & Informatica(荷兰数学与计算机科学研究院)
Rensselaer Polytechnic Institute(伦斯勒理工学院);UT Southwestern Medical Center(德克萨斯大学西南医学中心);Stony Brook University(石溪大学);U.S. Food and Drug Administration(美国食品药品监督管理局)
MDAA-Diff: CT-Guided Multi-Dose Adaptive Attention Diffusion Model for PET Denoising
School of Biomedical Engineering, Southern Medical University(南方医科大学生物医学工程学院);School of Biomedical Engineering, Shanghai Jiao Tong University(上海交通大学生物医学工程学院);Nanfang PET Center, Nanfang Hospital Southern Medical University(南方医科大学南芳医院PET中心)
SDCNet: Smoothed Dense-Convolution Network for Restoring Low-Dose Cerebral CT Perfusion
University of Florida(佛罗里达大学)
随着公众对医学成像中累积的辐射暴露引起的潜在癌症风险和健康危害的大量关注,减少基于X射线的医学成像(诸如计算机断层扫描灌注(CTP))中的辐射剂量已经引起了重大的研究兴趣。在本文中,我们采用基于深度卷积神经网络(CNN)的方法,并引入平滑密集卷积神经网络(SDCNet)来从低剂量图像恢复高剂量质量CTP图像。SDCNet由通过跳跃连接级联的子网络块组成,以从成对的低/高剂量CT扫描中推断噪声(差异)。SDCNet可以有效地去除实际低剂量CT扫描中的噪声,提高医学图像的质量。我们评估了数千个CT灌注帧的重建图像去噪和灌注图量化,包括脑血流量(CBF)和脑血容量(CBV)的建议架构。SDCNet在视觉和定量结果方面都实现了高性能,具有良好的计算效率,与最先进的方法相比毫不逊色。\textit{The code is available at \url{https://github.com/cswin/RC-Nets}}。