LaNi $_5$粉末填充床有效导热系数的测定
Measurement of effective thermal conductivity of LaNi$_5$ powder packed bed
摘要:
利用自制的保护热板(GHP)装置对LaNi $_5$粉末填充床的有效导热系数进行了分析。在这里,GHP被设计用于精确测量金属氢化物粉末的有效热导率,即使样品量很小(2.12 $\times$ 10 $^4$ mm $^3$)。通过二维稳态热传导分析确定了样品容器和装置的尺寸。通过标定实验和不确定度分析,验证了GHP的准确性。通过对LaNi $_5$填充床的残余热导率的测定,估算了颗粒尺寸对LaNi $_5$填充床接触因子的影响。将Yagi和Kunii(YK)模型应用于LaNi $_5$填充床的有效导热系数,重新分析了接触因子和气体导热系数对气膜特征长度的影响。对模型中的因子进行了修正,并与文献中的实验数据进行了对比验证。
英文摘要:
Effective thermal conductivity of LaNi$_5$ powder packed bed was analyzed with customized guarded hot-plate (GHP) apparatus. Here, GHP was designed for precise measurement of effective thermal conductivity of metal-hydride powders even with small sample amounts (2.12$\times$10$^4$ mm$^3$). Dimensions of sample container and apparatus were determined through two-dimensional (2-D) steady-state heat conduction analysis. Calibration experiment and uncertainty analysis were conducted to validate the accuracy of the GHP. Based on the measurements of the residual thermal conductivity of the LaNi$_5$ packed bed, effect of particle size on contact factor of LaNi$_5$ packed bed was estimated. By applying the Yagi and Kunii (YK) model to the effective thermal conductivity of LaNi$_5$ packed bed, effect of contact factor and gas thermal conductivity on characteristic length of gas film were newly analyzed. Factors of YK model were modified in present work and validated through comparison with experimental data from previous literature.