基于流动依赖的颗粒床热导率和近壁阻力的移动颗粒床传热系数
Heat Transfer Coefficients of Moving Particle Beds from Flow-Dependent Particle Bed Thermal Conductivity and Near-Wall Resistance
AI总结:
本文研究了流动颗粒床热物理性质变化对传热系数计算的影响,通过实验测定流动颗粒床热导率和近壁气隙,计算了不同陶瓷颗粒在不同工况下的传热系数,并应用于平行板换热器设计。
摘要:
确定流动填充颗粒床的传热系数对于颗粒换热器及其他热过程的设计至关重要。尽管此类致密颗粒流属于众所周知的平塞流(plug-flow)流型,但颗粒材料的离散特性改变了流动颗粒床在近壁区和体区内的热传输过程,使其与静止颗粒床不同。因此,基于静止颗粒床热导率的传热关联式可能不适用于换热器中的流动颗粒。早期的研究通过将颗粒介质视为具有近壁热阻串联的平塞流连续体,与实验取得了合理的一致性。然而,由于流动颗粒床测量的困难,连续体的属性往往是从静止床的测量中获得的。在本研究中,发现静止床的属性对颗粒填充方法高度敏感,并且在颗粒流动开始时,颗粒床热导率降低,近壁热阻(以有效气隙厚度衡量)增加。静止和流动颗粒床热物理性质的这些变化可能导致传热系数计算出现误差。因此,使用实验确定的流动颗粒床热导率和近壁气隙,计算了陶瓷颗粒——CARBOCP40/100(275μm)、HSP40/70(404μm)和HSP16/30(956μm);在速度为5-15mm s-1;温度为300-650°C条件下的颗粒流传热系数。CP40/100和HSP40/70的热导率和气隙值进一步被用于计算不同平行板换热器尺寸下,不同颗粒床温度和速度的传热系数。
英文摘要:
Determination of heat transfer coefficients for flowing packed particle beds is essential to the design of particle heat exchangers, and other thermal processes. While such dense granular flows fall into the well-known plug-flow regime, the discrete nature of granular materials alters the thermal transport processes in both the near-wall and bulk regions of flowing particle beds from their stationary counterparts. As a result, heat transfer correlations based on the stationary particle bed thermal conductivity could be inadequate for flowing particles in a heat exchanger. Earlier works have achieved reasonable agreement with experiments by treating granular media as a plug-flow continuum with a near-wall thermal resistance in series. However, the properties of the continuum were often obtained from measurements on stationary beds owing to the difficulty of flowing bed measurements. In this work, it was found that the properties of a stationary bed are highly sensitive to the method of particle packing and there is a decrease in the particle bed thermal conductivity and increase in the near-wall thermal resistance, measured as an effective air gap thickness, on the onset of particle flow. These variations in the thermophysical properties of stationary and flowing particle beds can lead to errors in heat transfer coefficient calculations. Therefore, the heat transfer coefficients for granular flows were calculated using experimentally determined flowing particle bed thermal conductivity and near-wall air gap for ceramic particles -CARBOCP40/100(275 um), HSP40/70(404um) and HSP16/30(956um); at velocities of 5-15mms-1; and temperatures of 300-650C. The thermal conductivity and air gap values for CP40/100 and HSP40/70 were further used to calculate heat transfer coefficients across different particle bed temperatures and velocities for different parallel-plate heat exchanger dimensions.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。