In this paper, we introduce a laboratory prototype of a solar energetic particle (SEP) detector which will operate along with other space-based instruments to give us more insight into the SEP physics. The instrument is designed to detect protons and electrons with kinetic energies from 10 to 100 MeV and from 1 to 10 MeV respectively. The detector is based on a scintillation cylinder divided into separated disks to get more information about detected particles. Scintillation light from isolated segments is collected by optical fibers and registered with silicon photo-multipliers (SiPM). The work contains the result of laboratory testing of the detector prototype. The detector channels were calibrated, energy resolution for every channel was obtained. Moreover, we present an advanced integral data acquisition and analysis technique based on Bayesian statistics, which will allow operation even during SEP events with very large fluxes.
The work is motivated by the need for better measurement tools to study acceleration and transport of SEP in the heliosphere as well as by the need for the monitoring tool to mitigate radiation hazard for equipment and people in space.
Three-dimensional finely grained plastic scintillator detectors bring many advantages in particle detectors, allowing a massive active target which enables a high-precision tracking of interaction products, excellent calorimetry and a sub-nanosecond time resolution. Whilst such detectors can be scaled up to several-tonnes, as required by future neutrino experiments, a relatively long production time, where each single plastic-scintillator element is independently manufactured and machined, together with potential challenges in the assembly, complicates their realisation. In this manuscript we …
This paper presents studies on application of convolutional neural network (CNN) to GEANT4 optical simulation data generated with a scintillator detector subdivided into 1 cubic cm, which is designed for the long-baseline neutrino experiment. Classification of interaction, regression of momentum, and segmentation of hits are demonstrated for single particle and neutrino-nucleon interaction events with well established CNN architectures by feeding reconstructed 2D projection images. In the study it is shown that the application of CNN to the 1 cm subdivided scintillator detector can provide a f…
We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of near-field reactor monitoring with sensitivity to antineutrino direction. SANDD comprises three different types of module. A detailed Monte Carlo simulation code was developed to match and validate the performance of each of the three modules. The combined model was then used to produce a prediction of the performance of the entire detector. Analysis cuts were esta…
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will eventually comprise a central module of 64 elongated segments of $^{6}$Li-doped pulse-shape-sensitive scintillator rods, each with a square cross section of 5.4 mm $\times$ 5.4 mm, surrounded by larger cro…
In this study, simulation-based design and optimization studies of a gadolinium loaded segmented plastic scintillator detector are presented for monitoring applications of nuclear reactors in Turkey using antineutrinos. For the first time in the literature, a multivariate analysis technique is introduced to suppress cosmic background for such a reactor antineutrino detector.
A method for reconstructing the direction of a fast neutron source using a segmented organic scintillator-based detector and deep learning model is proposed and analyzed. The model is based on recurrent neural network, which can be trained by a sequence of data obtained from an event recorded in the detector and suitably pre-processed. The performance of deep learning-based model is compared with the conventional double-scatter detection algorithm in reconstructing the direction of a fast neutron source. With the deep learning model, the uncertainty in source direction of 0.301 rad is achieved…
This study presents a new concept of segmented antineutrino detector based on hexagonal plastic scintillator bars for detecting antineutrinos from a nuclear reactor core. The choice of hexagonal scintillator bars is original and provides compactness. The proposed detector detects antineutrinos via inverse beta decay (IBD) with the prompt-delayed double coincidence. Owing to its segmented structure, the background, which satisfies the delayed coincidence condition can be eliminated by applying proper event selection cuts. In this manner, the main focus is to determine proper selection criteria …
This paper describes the data acquisition system used for data readout from a segmented detector of reactor antineutrinos with active shielding. Theoretical approach to the data acquisition is described and two possible solutions using QDCs and digitizers are discussed. Also described are the results of the DAQ performance during routine data taking operation of DANSS. DANSS (Detector of the reactor AntiNeutrino based on Solid Scintillator) is a project aiming to measure a spectrum of reactor antineutrinos using inverse beta decay (IBD) in a plastic scintillator. The detector is located close …
T2K (Tokai-to-Kamioka) is a long-baseline neutrino experiment in Japan designed to study various parameters of neutrino oscillations. A near detector complex (ND280) is located 280~m downstream of the production target and measures neutrino beam parameters before any oscillations occur. ND280's measurements are used to predict the number and spectra of neutrinos in the Super-Kamiokande detector at the distance of 295~km. The difference in the target material between the far (water) and near (scintillator, hydrocarbon) detectors leads to the main non-cancelling systematic uncertainty for the os…
Technology developed for the T2K electromagnetic calorimeter has been adapted to make a small footprint, reliable, segmented detector to characterise anti-neutrinos emitted by nuclear reactors. The device has been developed and demonstrated by the University of Liverpool and underwent field tests at the Wylfa Magnox Reactor on Anglesey, UK. It was situated in a 20\,ft ISO shipping container, above ground, roughly 60\,m from the 1.5\,\GWt\ reactor core. Based on the design of the T2K Near Detector ECal, the device detects anti-neutrinos through the distinctive delayed coincidence signal of inve…
This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the $^{6}$Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850$\pm$20 PE/MeV, an energy reso…
A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation, and the method of analysis. The detector is capable of observing very low neutron fluxes in the presence of ambient gamma background and does not require scintillator pulseshape discrimination. The spectrometer was characterized for its energy response in fast neutron fields of 2.5 MeV and 14 MeV, and the results are compared with Monte Carlo simulations. Meas…
We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and $^3$He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few MeV to 1 GeV. FaNS-2 utilizes capture-gated spectroscopy to identify neutron events and reject backgrounds. Neutrons deposit energy in the plastic scintillator before capturing on a $^3$He nucleus in the proportional counters. Segmentation improves neutron energy reconstruction while the large volume of scintillator increases sensitivity to low neutron flux…
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator technology. The detector target uses cubes of polyvinyltoluene interleaved with $^6$LiF:ZnS(Ag) phosphor screens to detect the products of the inverse beta decay reaction. A multi-tonne detector system built from these individual cells can provide precise localisation of scintillation signals, making efficient use of the detector volume. Monte Carlo simulations …
A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for ${\rm β}$ particles. A Position-Sensitive Photo-Multiplier Tube (PSPMT) is coupled with a $48\times48$ segmented YSO crystal. To demonstrate its capabilities, a known short-lived isomer in $^{76}$Ni and the ${\rm β}$ decay of $^{74}$Co we…
The Miniaturized Detector for Application in Space (MIDAS) is a compact device with dimensions 5 x 5 x 1 cm3 which combines position sensitive Si detectors and a fast neutrons spectrometer. MIDAS is developed with purpose to act as a linear energy transfer (LET) spectrometer for the charged particles and measure dose and dose equivalent from both charged particles and neutrons. It is based on fully depleted monolithic active Si pixel sensors for the charged track and energy deposition measurements, while a plastic scintillator read out by a silicon photomultiplier is used to determine energy d…
DANSS is a one cubic meter highly segmented plastic scintillator detector. Its 2500 one meter long scintillator strips have a Gd-loaded reflective cover. The DANSS detector is placed under an industrial 3.1GW reactor of the Kalinin Nuclear Power plant 350km NW from Moscow. The distance to the core ia varied on-line from 10.7m to 12.7m. Recent results on searches for a sterile neutrino are presented as well as measurements of the antineutrino spectrum dependence on the fuel composition. All results are preliminary. PACS: 14.60.Pq, 14.60.St
Digital Electronics for the Pierre Auger Observatory AMIGA Muon Counters
“俄歇μ子和地面阵列填充”(AMIGA)项目为皮埃尔俄歇天文台提供直接μ子计数能力,并将其能量探测范围扩展到0.3 EeV。它目前由61个探测器对(切伦科夫表面探测器和埋μ子计数器)分布在一个750米的三角形网格上的23.5平方公里的区域。每个计数器依赖于分段的闪烁体模块,该闪烁体模块在给定时隙在每个闪烁体段上存储逻辑“0”和“1”的训练。μ子计数器数据以320 MHz进行采样和存储,从而允许检测单个光电子和实施离线触发器,该离线触发器旨在减轻多像素PMT串扰和暗速率不良效应。采集由围绕低功耗Cyclone III FPGA构建的数字电子设备执行。本文介绍了数字电子学设计,内部和外部同步方案,硬件测试,并从天文台的第一个结果。
A new high-precision detector for studying neutrons from beta-delayed neutron emission and direct reaction studies is proposed. The Neutron dEtector with Xn Tracking (NEXT) array is designed to maintain high intrinsic neutron detection efficiency while reducing uncertainties in neutron energy measurements. A single NEXT module is composed of thin segments of plastic scintillator, each optically separated, capable of neutron-gamma discrimination. Each segmented module is coupled to position sensitive photodetectors enabling the high-precision determination of neutron time of arrival and interac…
The SoLid collaboration is currently operating a 1.6 tons neutrino detector near the Belgian BR2 reactor, with main goal the observation of the oscillation of electron antineutrinos to previously undetected flavor states. The highly segmented SoLid detector employs a compound scintillation technology based on PVT scintillator in combination with a $^{6}$LiF:ZnS(Ag) screens containing $^{6}$Li isotopes. The experiment has demonstrated a channel-to-channel response that can be controlled to the level of a few percent, and energy resolution of better than 14\% at 1 MeV, and a determination of the…
DANSS is a highly segmented 1~m${}^3$ plastic scintillator detector. Its 2500 one meter long scintillator strips have a Gd-loaded reflective cover. The DANSS detector is placed under an industrial 3.1~$\mathrm{GW_{th}}$ reactor of the Kalinin Nuclear Power Plant 350~km NW from Moscow. The distance to the core is varied on-line from 10.7~m to 12.7~m. The reactor building provides about 50~m water-equivalent shielding against the cosmic background. DANSS detects almost 5000 $\widetildeν_e$ per day at the closest position with the cosmic background less than 3$\%$. The inverse beta decay process …
The aim of this study is to design and evaluate a simple free running Analog-Digital Converter (ADC) based on the Field Programmable Gate Array (FPGA) device to accomplish the energy and position readout of the silicon photomultiplier (SiPM) array for application as PET scanners. This simple FPGA-ADC based on a carry chain Time-Digital Converter (TDC) implemented on a Kintex-7 FPGA consists of only one off-chip resistor so it has greater advantages in improving system integration and reducing cost than commercial chips. In this paper, a FPGA-ADC based front-end electronics prototype is present…
We summarize in this paper the detector R&D performed in the framework of the ERC ENUBET Project. We discuss in particular the latest results on longitudinally segmented shashlik calorimeters and the first HEP application of polysiloxane-based scintillators.
Search for a light sterile neutrino is currently a hot topic of neutrino physics, arising from the so-called gallium and reactor anomalies, in which a deficit of neutrinos was observed with respect to expectations. Such anomalies could be explained by short distance oscillations towards a sterile state, with $Δ\mathrm{m}^2\sim$1\,eV$^2$. The STEREO detector has been designed to track the electron anti-neutrino energy spectrum distortion from 3 to 8\,MeV due to such a new $L/E$ oscillation, and should therefore confirm or reject the light sterile neutrino hypothesis. Electron anti-neutrinos pro…
The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine …
The SoLid experiment aims to resolve the reactor neutrino anomaly by searching for electron-to-sterile anti-neutrino oscillations. The search will be performed between 5.5 and 10 m from the highly enriched uranium core of the BR2 reactor at SCK-CEN. The experiment utilises a novel approach to anti-neutrino detection based on a highly segmented, composite scintillator detector design. High experimental sensitivity can be achieved using a combination of high neutron-gamma discrimination using 6 LiF:ZnS(Ag) and precise localisation of the inverse beta decay products. This compact detector system …
Muon-neutrino elastic scattering on electrons is an observable neutrino process whose cross section is precisely known. Consequently a measurement of this process in an accelerator-based $ν_μ$ beam can improve the knowledge of the absolute neutrino flux impinging upon the detector; typically this knowledge is limited to $\sim$ 10% due to uncertainties in hadron production and focusing. We have isolated a sample of 135 $\pm$ 17 neutrino-electron elastic scattering candidates in the segmented scintillator detector of MINERvA, after subtracting backgrounds and correcting for efficiency. We show h…
The Radiation Assessment Detector (RAD), onboard the Mars Science Laboratory (MSL) rover Curiosity, has been measuring the energetic charged and neutral particles and the radiation dose rate on the surface of Mars since the landing of the rover in August 2012. In contrast to charged particles, neutral particles (neutrons and gamma-rays) are measured indirectly: the energy deposition spectra produced by neutral particles are complex convolutions of the incident particle spectra with the detector response functions. An inversion technique has been developed and applied to jointly unfold the depo…
Current models of antineutrino production in nuclear reactors predict detection rates and spectra at odds with the existing body of direct reactor antineutrino measurements. High-resolution antineutrino detectors operated close to compact research reactor cores can produce new precision measurements useful in testing explanations for these observed discrepancies involving underlying nuclear or new physics. Absolute measurement of the 235U-produced antineutrino spectrum can provide additional constraints for evaluating the accuracy of current and future reactor models, while relative measuremen…
We report a search for a magnetic monopole component of the cosmic-ray flux in a 95-day exposure of the NOvA experiment's Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of $2\times 10^{-14} \mathrm{cm^{-2}s^{-1}sr^{-1}}$ at 90% C.L. for monopole speed $6\times 10^{-4} < β< 5\times 10^{-3}$ and mass greater than $5\times 10^{8}$ GeV. Because of NOvA's small overburden of 3 meters-water equivalent, this constraint covers a previously unex…