The present $\mathrm{R}\&\mathrm{D}$ activities for the International Large Detector Time Projection Chamber (ILD-TPC) concern the adoption of the micro pattern devices for the gaseous amplification stage. Seven Micromegas modules which are commissioned on the end-plate of a Large Prototype TPC (LPTPC) at DESY, were tested with a 5 GeV electron beam, under a 1 T magnetic field. During experiments, reduced signal sensitivity as well as distortion in the reconstructed track was observed at the boundaries of these modules. Electrostatic field inhomogeneity near the module boundaries was considered to be the possible major reason behind these observations. In the present work, this hypothesis has been explored using the Garfield simulation framework. It has been possible to contain the computational complexity of the problem with suitable simplifications. Qualitative and quantitative agreements with experimental results have been achieved. Possibility of mitigating the problems has been proposed using the same simulation framework.
The aim of the presented work was to develop further techniques based on a Micromegas-TPC, in order to reach a high gas gain with good energy resolution, and to search for gas mixtures suitable for rare event detection. This paper focuses on xenon, which is convenient for the search of neutrinoless double beta decay in 136 Xe. Conversely, a small admixture of xenon to CF 4 can reduce attachment in the latter. This gas mixture would be suitable for dark matter searches and the study of solar and reactor neutrinos. Various configurations of the Micromegas plane were investigated and are describe…
If Dark Matter is made of Weakly Interacting Massive Particles (WIMPs) with masses below $\sim$20 GeV, the corresponding nuclear recoils in mainstream WIMP experiments are of energies too close, or below, the experimental threshold. Gas Time Projection Chambers (TPCs) can be operated with a variety of target elements, offer good tracking capabilities and, on account of the amplification in gas, very low thresholds are achievable. Recent advances in electronics and in novel radiopure TPC readouts, especially micro-mesh gas structure (Micromegas), are improving the scalability and low-background…
Since the summer of 2003, a large Micromegas TPC prototype (1000 channels, 50 cm drift, 50 cm diameter) has been operated in a 2T superconducting magnet at Saclay. A description of this apparatus and first results from cosmic ray tests are presented. Additional measurements using simpler detectors with a laser source, an X-ray gun and radio-active sources are discussed. Drift velocity and gain measurements, electron attachment and aging studies for a Micromegas TPC are presented. In particular, using simulations and measurements, it is shown that an $Argon-CF_4$ mixture is optimal for operatio…
The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $μ$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new MPGD readout concept of charge dispersion to a prototype GEM-TPC and demonstrated the feasibility of achieving good resolution with pads similar in width to the ones used for the proportional wire TPC. …
Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we present the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.300 kg, with an energy threshold below 0.4 keVee and fully built with previously selected radiopure materials. This article describes the actual setup, the first results of the comissioning in Ar+2\%iC$_4$H$_{10}$ at 1.2 bar and the future updates for a p…
The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The new MPGD readout technique of charge dispersion can achieve good resolution without resorting to narrow pads. This has been demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmi…
Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.3 kg, with an energy threshold below 0.4 keVee and fully built with previously selected radiopure materials. This work describes the commissioning of the actual setup situated in a laboratory on surface and the updates needed for a possible physics run a…
We present ion backflow measurements in a Micromegas (MICRO-MEsh GASeous detector) TPC device developed for the next high energy electron-positron linear collider under study and a simple explanation for this backflow. A Micromegas micro-mesh has the intrinsic property to naturally stop a large fraction of the secondary positive ions created in the avalanche. It is shown that under some workable conditions on the pitch of the mesh and on the gas mixture, the ion feedback is equal to the field ratio (ratio of the drift electric field to the amplification field). Measurements with an intense X-r…
The results of a beam test performed at the KEK PS in June 2005 are presented. Drift properties of an argon-isobutane mixture have been accurately measured and compared with predictions at magnetic fields between 0 and 1 Tesla. The r.m.s. point resolution of a padrow is compared with simulation and with an analytical calculation. The fundamental limitations due to detector geometry and gas properties are reviewed and the measured performances of the detector are found to be close to this limit. A numerical application to the case of a Linear Collider TPC is presented.
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure uses a resistive anode to spread the charges over several pads to improve the space point resolution. This innovative technique is combined with the bulk-Micromegas technology to compose the "Encapsula…
We conducted a series of beam tests of prototype TPCs for the International Linear Collider (ILC) experiment, equipped with an MWPC, a MicroMEGAS, or GEMs as a readout device. The prototype operated successfully in a test beam at KEK under an axial magnetic field of up to 1 T. The analysis of data is now in progress and some of the preliminary results obtained with GEMs and MicroMEGAS are presented along with our interpretation. Also given is the extrapolation of the obtained spatial resolution to that of a large TPC expected for the central tracker of the ILC experiment.
Low radioactive material screening is becoming essential for rare event search experiments, such as neutrinoless double beta decay and dark matter searches in underground laboratories. A gaseous time projection chamber (TPC) can be used for such purposes with large active areas and high efficiency. A gaseous TPC with a Micromegas readout plane of approximately 20$\times$20 cm$^2$ is successfully constructed for surface alpha contamination measurements. We have characterized the energy resolution, gain stability, and tracking capability with calibration sources. With the unique track-related ba…
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some drift gas mixtures that are stable in the absence of the neutron beam. The discharges result from recoil ions close to the MICROMEGAS that deposit high specific ionization density and have a limited dif…
In this work we present a systematic study of Micromegas detectors in high pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains and energy resolutions for 22.1 keV X-rays are measured for pressures between 1 and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We observe stable operation at all pressures, and a strongly enhanced gas gain, suggestive of Penning-like energy-transfer processes. The effect is present at all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3 %. Operating in this concentration range, the maximum g…
We present in this work measurements performed with a small Micromegas-TPC using a xenon-trimethylamine (Xe-TMA) Penning-mixture as filling gas. Measurements of gas gain and energy resolutions for 22.1 keV X-rays are presented, spanning several TMA concentrations and pressures between 1 and 10 bar. Across this pressure range, the best energy resolution and largest increase in gain at constant field (a standard figure for characterizing Penning-like energy transfers) is observed to be in the 1.5%-2.5% TMA region. A gain increase (at constant field) up to a factor 100 and a best energy resolutio…
The Particle And Astrophysical Xenon Experiment III (PandaX-III) is an experiment to search for the Neutrinoless Double Beta Decay (NLDBD) using 200 kg radio-pure high-pressure gaseous xenon TPC with Micromegas detectors at both ends and cathode in the middle. A small-scale TPC equipped with 7 Microbulk Micromegas detectors is developed as the prototype detector. 128 channels are readout following an X-Y design with strips of 3 mm pitch (64 channels each direction) from one Micromegas module. Highly integrated front-end electronics composed of 4 front-end cards with 1024 readout channels is de…
T2K is a long baseline neutrino experiment that has been operating since 2009 providing some of the world-wide leading measurements for neutrino oscillation parameters. An upgrade for the Near Detector, ND280, of T2K has been proposed. It includes the installation of two new Time Projection Chambers (TPC) based on a new read-out technology: the resistive anode MicroMegas (RMM). This technology is expected to reduce the number of electronic channels while maintaining or improving the current ND280 TPCs' bulk MicroMegas perfomance. A series of tests have been performed and further studies are on…
The search for the neutrinoless double beta decay (0$νββ$) is one of the most important quests nowadays in neutrino physics. Among the different techniques used, high pressure xenon (HPXe) gas time projection chambers (TPC) stand out because they allow to image the topology of the 0$νββ$ event (one straggling track ending in two blobs), and use it to discriminate signal from background events. Recent results with microbulk Micromegas in Xe + trimethylamine (TMA) mixtures show high promise in terms of gain, stability of operation, and energy resolution at high pressures (up to 10 bar). The addi…
An eight chip InGrid module has been tested as readout of a prototype time projection chamber. The construction of the modules as well as first preliminary results are presented. The InGrids, a Micromegas like amplification structure with a pixel ASIC, have been produced on wafer-level in a photolithographic process. For the measurements a newly developed readout system based on the Scalable Readout System was used.
In the search for the neutrinoless double beta decay of $^{136}$Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which may provide extra discrimination from background events. The PandaX-III experiment has recently proposed a 200 kg HPXe-TPC based on Micromegas readout planes, to be located at the Jinping Underground Laboratory in China. Its detection concept is based on two results obtained within the T-REX project: Micromegas readouts can be built with extremely low level…
We report the design, construction, and initial commissioning results of a large high pressure gaseous Time Projection Chamber (TPC) with Micromegas modules for charge readout. The detector vessel has an inner volume of about 600 L and an active volume of 270 L. At 10 bar operating pressure, the active volume contains about 20 kg of xenon gas and can image charged particle tracks. Drift electrons are collected by the charge readout plane, which accommodates a tessellation of seven Micromegas modules. Each of the Micromegas covers a square of 20 cm by 20 cm. A new type of Microbulk Micromegas i…
Ion backflow is one of the effects limiting the operation of a gaseous detector at high flux, by giving rise to space charge which perturbs the electric field. The natural ability of bulk Micromegas to suppress ion feedback is very effective and can help the TPC drift volume to remain relatively free of space charge build-up. An efficient and precise measurement of the backflow fraction is necessary to cope up with the track distortion due to the space charge effect. In a subtle but significant modification of the usual approach, we have made use of two drift meshes in order to measure the ion…
An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 resistive MicroMegas modules for gas amplification. A first prototype of resistive MicroMegas has been designed, built, installed in the HARP field cage, and exposed to a beam of charged particles at CERN. The data have been used to characterize the performances of the resistive MicroMegas module. A spatial resolution of 300 $μm$ and a deposited energy resolution of 9% were observed for horizontal e…
The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself as a good choice for its performances in terms of gas gain uniformity, energy and space point resolution, and its capability to efficiently pave large readout surfaces with minimum dead zone. The present work involves the comparison of this standard bulk with a relatively less used bulk Micromegas detector having a larger amplification gap of 192 micron. Dete…
NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT $0νββ$ experiment, although the experiment's first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy $γ$-rays emitted by a $^{241}$Am sourc…
The readout electronics of a Micromegas (MM) module consume nearly 26 W of electric power, which causes the temperature of electronic board to increase upto $70\,^{\circ}{\rm C}$. Increase in temperature results in damage of electronics. Development of temperature gradient in the Time Projection Chamber (TPC) may affect precise measurement as well. Two-phase CO$_2$ cooling has been applied to remove heat from the MM modules during two test beam experiments at DESY, Hamburg. Following the experimental procedure, a comprehensive study of the cooling technique has been accomplished for a single M…
The ILD concept, one of two proposed detector concepts for the planned International Linear Collider (ILC), foresees a Time Projection Chamber (TPC) as the main tracking detector. The LCTPC (Linear Collider TPC) collaboration pursues R&D to develop such a TPC based on the best state-of-the-art technology. After tests with smaller prototypes, the current efforts focus on studies using a large prototype with a diameter of 770 mm and a length of 610 mm. This prototype can accommodate seven read-out modules of a size comparable to the ones that would be used in the final TPC. Several prototypes of…
Micromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time Projection Chambers (TPCs) in the field of Rare Event searches (dealing with dark matter, axions or double beta decay). In these experiments, the radiopurity of the detector components and surrounding materials is measured and finely controlled in order to keep the experimental background as low as possible. In the present paper, the first measurement of the radi…
The third generation of the Beijing Electron Spectrometer, BESIII, is an apparatus for high energy physics research. The hunting of new particles and the measurement of their properties or the research of rare processes are sought to understand if the measurements confirm the Standard Model and to look for physics beyond it. The detectors ensure the reconstruction of events belonging to the sub-atomic domain. The operation and the efficiency of the BESIII inner tracker is compromised due to the the radiation level of the apparatus. A new detector is needed to guarantee better performance and t…
The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this…
Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed an original prototype detector which combines a large pixelated Micromegas coupled with a fast, self-triggering, electronics. Aspects of the two-chamber module in oper…
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal), 0.8 +-0.15 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent mixture. The TPC, that houses 1.1 kg of gas in its active volume, operated continuously for 100 liv…
A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift $\times$ 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (~23 l) so as to contain long (~20 cm) electron tracks. First results obtained at 1 bar for Xenon and trimethylamine (Xe-(2 %)TMA) mixture are present…
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred candidate for Dark Matter. WIMPs should interact with the nuclei of detectors. If a robust signal is eventually observed in direct detection experiments, the best signature to confirm its Galactic origin would be the nuclear recoil track direction. The MIMAC collaboration has developed a low pressure gas detector providing both the kinetic energy and three-dimensional track reconstruction of nuclear recoils. In this paper we report the first ever observations of $^{19}$F nuclei tracks in a $5$ cm drift prototype MIMAC d…