arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2003.13440eess.IVcs.CV

Computer Aided Detection for Pulmonary Embolism Challenge (CAD-PE)

Ferdowsi University of Mashhad(马什哈德菲尔多西大学);Universidad de Alicante(阿利坎特大学);Sierra Research S.L.(塞拉研究有限公司);Unidad de Radiodiagnostico, Madrid(马德里放射诊断科);CIBERBBN(西班牙生物医学网络研究中心);Brigham and Women’s Hospital(布里格姆妇女医院);Corades S.L.(科拉德斯有限公司);LNM Institute of Information Technology(LNM信息技术学院);Arizona State University(亚利桑那州立大学)
Germán González, Daniel Jimenez-Carretero, Sara Rodríguez-López, Carlos Cano-Espinosa, Miguel Cazorla, Tanya Agarwal, Vinit Agarwal, Nima Tajbakhsh, Michael B. … 展开作者

Germán González, Daniel Jimenez-Carretero, Sara Rodríguez-López, Carlos Cano-Espinosa, Miguel Cazorla, Tanya Agarwal, Vinit Agarwal, Nima Tajbakhsh, Michael B. Gotway, Jianming Liang, Mojtaba Masoudi, Noushin Eftekhari, Mahdi Saadatmand, Hamid-Reza Pourreza, Patricia Fraga-Rivas, Eduardo Fraile, Frank J. Rybicki, Ara Kassarjian, Raúl San José Estépar, Maria J. Ledesma-Carbayo

英文摘要:

Rationale: Computer aided detection (CAD) algorithms for Pulmonary Embolism (PE) algorithms have been shown to increase radiologists' sensitivity with a small increase in specificity. However, CAD for PE has not been adopted into clinical practice, likely because of the high number of false positives current CAD software produces. Objective: To generate a database of annotated computed tomography pulmonary angiographies, use it to compare the sensitivity and false positive rate of current algorithms and to develop new methods that improve such metrics. Methods: 91 Computed tomography pulmonary angiography scans were annotated by at least one radiologist by segmenting all pulmonary emboli visible on the study. 20 annotated CTPAs were open to the public in the form of a medical image analysis challenge. 20 more were kept for evaluation purposes. 51 were made available post-challenge. 8 submissions, 6 of them novel, were evaluated on the 20 evaluation CTPAs. Performance was measured as per embolus sensitivity vs. false positives per scan curve. Results: The best algorithms achieved a per-embolus sensitivity of 75% at 2 false positives per scan (fps) or of 70% at 1 fps, outperforming the state of the art. Deep learning approaches outperformed traditional machine learning ones, and their performance improved with the number of training cases. Significance: Through this work and challenge we have improved the state-of-the art of computer aided detection algorithms for pulmonary embolism. An open database and an evaluation benchmark for such algorithms have been generated, easing the development of further improvements. Implications on clinical practice will need further research.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑