arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1912.08474cond-mat.str-el
收藏

Anderson杂质模型对猝灭响应的含时谱函数及其在时间分辨光电子能谱中的应用

Time-dependent spectral functions of the Anderson impurity model in response to a quench with application to time-resolved photoemission spectroscopy

H. T. M. Nghiem, H. T. Dang, T. A. Costi

摘要:

我们研究了Anderson杂质模型在猝灭后的含时谱函数$A(ω,t)$的几种定义,并在含时数值重整化群方法中进行了讨论。在二次延迟格林函数$G^r(t_1,t_2)$方面,定义在时间变量$t$相对于$t_1$和/或$t_2$的选择上不同。在先前的研究中[Nghiem { \it et al.}物理修订信函119,156601(2017)],我们研究了从${\rm Im}[G^r(t_1,t_2)]$ w.r.t.时间差$t'=t_1-t_2$与$t=t_2$。在这里,我们推导出延迟格林函数的表达式,选择$t=t_1$和平均时间$t=(t_1+t_2)/2$,在TDNRG方法。我们比较和对比所得到的$A(ω,t)$的不同选择的时间参考。对于时间基准的所有选择,在TDNRG中还推导出了较小、较大和高级格林函数的表达式。平均时间较小的格林函数$G^<(ω,t)$是特别有趣的,因为它决定了依赖于时间的占据态密度$N(ω,t)=G^<(ω,t)/(2πi)$,一个量,确定在时间分辨泵浦探测光电发射光谱的光电发射电流。我们提出了$N(ω,t)$的安德森模型淬火后的计算,并讨论了由此产生的时间演化的光谱特征,如近藤共振和高能量峰。我们还讨论了$N(ω,t)$长时间热化的问题。最后,我们使用$N(ω,t)$的结果来计算安德森模型的时间分辨的光发射电流后淬火(作为泵),并研究不同的行为,可以观察到不同的分辨率时间的高斯探测脉冲。

英文摘要:

We investigate several definitions of the time-dependent spectral function $A(ω,t)$ of the Anderson impurity model following a quench and within the time-dependent numerical renormalization group method. In terms of the two-time retarded Green function $G^r(t_1,t_2)$, the definitions differ in the choice of the time variable $t$ with respect to $t_1$ and/or $t_2$. In a previous study [Nghiem {\it et al.} Phys. Rev. Lett. 119, 156601 (2017)], we investigated the spectral function, obtained from the Fourier transform of ${\rm Im}[G^r(t_1,t_2)]$ w.r.t. the time difference $t'=t_1-t_2$, with $t=t_2$. Here, we derivie expressions for the retarded Green function for the choices $t=t_1$ and the average time $t=(t_1+t_2)/2$, within the TDNRG approach. We compare and contrast the resulting $A(ω,t)$ for the different choices of time reference. Expressions for the lesser, greater and advanced Green functions are also derived within TDNRG for all choices of time reference. The average time lesser Green function $G^<(ω,t)$ is particularly interesting, as it determines the time-dependent occupied density of states $N(ω,t)=G^<(ω,t)/(2πi)$, a quantity that determines the photoemission current in time-resolved pump-probe photoemission spectroscopy. We present calculations for $N(ω,t)$ for the Anderson model following a quench, and discuss the resulting time evolution of the spectral features, such as the Kondo resonance and high-energy peaks. We also discuss the issue of thermalization at long times for $N(ω,t)$. Finally, we use the results for $N(ω,t)$ to calculate the time-resolved photoemission current for the Anderson model following a quench (acting as the pump) and study the different behaviors that can be observed for different resolution times of a Gaussian probe pulse.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑