基于起动瞬态电流的18台定速电机监督负载识别
Supervised load identification of 18 fixed-speed motors based on their turn-on transient current
摘要:
一些研究已经表明,瞬态电流可以成功地用于识别电力负载。然而,大多数所提出的方法进行了验证,只使用少数的负载,其电气性能往往显着不同。因此,这里使用18个不同的定速电机在真实的工作环境中进行了更具挑战性的实证研究。另一个困难是在稳态期间将电流幅度归一化为1~A的值。结果表明,即使在这些条件下,分类器也可以区分这18个电机,在监督训练期后的f1分数为97.7%。除此之外,还测试了仅使用瞬态电流是否可以推断出定速电机的机械输出类型(泵、风扇或压缩机)。然而,分类结果表明,这是不可能的。
英文摘要:
Several studies have already shown that the transient current can be successfully used to identify electric loads. However, most of the proposed methods were validated using only a handful of loads whose electric properties often differed significantly from each other. Therefore, a much more challenging empirical study was carried out here using 18 different fixed-speed motors in a real work environment. A further difficulty was introduced by normalizing the current amplitude to a value of 1~A during steady state. It is shown that a classifier can distinguish these 18 motors even under those conditions with an f1-score of 97.7% after a supervised training period. In addition to that it was tested whether the mechanical output type (pump, fan or compressor) of the fixed-speed motors could be inferred using only the transient current. However, the classification results indicate that this is not possible.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。