江门地下中微子观测站水切伦科夫探测器镭测量系统的研制

Developing the radium measurement system for the water Cherenkov detector of the Jiangmen Underground Neutrino Observatory

Lifei Xie, Jinchang Liu, Shoukang Qiu, Cong Guo, Changgen Yang, Quan Tang, Yongpeng Zhang, Peng Zhang

摘要:

江门地下中微子观测站拟采用20~ k吨液体闪烁探测器测定中微子质量等级。对探测器的所有组件都提出了严格的放射性纯度要求。根据MC模拟结果,切伦科夫探测器的水氡浓度应小于200 mBq/m $^3$。氡的前身镭也应该得到认真考虑。为了测量水中的镭浓度,研制了一套由镭提取系统、氡射气室和氡浓度测量系统组成的镭测量系统。本文介绍了一天测量灵敏度为$\sim$ 5~mBq/$^3$的气体氡浓度测量系统的改进情况,以及一天测量灵敏度为$\sim$ 23~mBq/$^3$的水中镭浓度测量系统的研制情况和大亚湾水样的测量结果。

英文摘要:

The Jiangmen Underground Neutrino Observatory is proposed to determine neutrino mass hierarchy using a 20~ktonne liquid scintillator detector. Strict radio-purity requirements have been put forward for all the components of the detector. According to the MC simulation results, the radon dissolved in the water Cherenkov detector should be below 200~mBq/m$^3$. Radium, the progenitor of radon, should also be taken seriously into account. In order to measure the radium concentration in water, a radium measurement system, which consists of a radium extraction system, a radon emanation chamber and a radon concentration measurement system, has been developed. In this paper, the updated radon concentration in gas measurement system with a one-day-measurement sensitivity of $\sim$5~mBq/m$^3$, the detail of the development of the radium concentration in water measurement system with a sensitivity of $\sim$23~mBq/m$^3$ as well as the measurement results of Daya Bay water samples will be presented.