arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1906.01846astro-ph.IMastro-ph.CO
收藏

近红外探测器中的增亮增胖效应--I.平坦自相关理论

Brighter-fatter effect in near-infrared detectors -- I. Theory of flat auto-correlations

Christopher M. Hirata, Ami Choi

摘要:

弱引力透镜研究的目的是测量遥远星系形状的微小变形,因此对理解天文图像中探测器引起的系统效应提出了非常严格的要求。宽视场红外巡天望远镜(WFIRST)将使用新的Teledyne H4RG-10探测器阵列进行近红外弱透镜测量,这使得可能的探测器系统的范围与使用光学CCD的传统弱透镜测量非常不同。在CCD中观察到的非线性检测器效应之一是更亮-更胖效应(BFE),其中已经在像素中积累的电荷改变电场几何形状并导致新电荷被偏转远离更亮的像素。在这里,我们描述的形式主义测量的BFE使用平场相关函数在红外探测器阵列。CCD平场的自相关通常用于测量BFE,但由于红外探测器阵列是在电荷"就位"的情况下读出的,所以平场相关性由相邻像素之间的电容串扰(像素间电容,或IPC)主导。相反,如果BFE存在并且不考虑它,则它可以使IPC的相关测量和增益的光子传输测量偏置。我们表明,因为红外探测器阵列可以读出非破坏性的,可以计算许多交叉关联函数之间的不同时间片的相同的平面曝光,和相关性由于IPC和BFE留下不同的印记。我们生成了一套模拟平场,并表明,基本的IPC和BFE参数可以提取,即使两者都存在于模拟。在BFE系数中存在高达12%的偏差,这可能是由从该分析中丢弃的高阶项引起的。

英文摘要:

Weak gravitational lensing studies aim to measure small distortions in the shapes of distant galaxies, and thus place very tight demands on the understanding of detector-induced systematic effects in astronomical images. The Wide-Field Infrared Survey Telescope (WFIRST) will carry out weak lensing measurements in the near infrared using the new Teledyne H4RG-10 detector arrays, which makes the range of possible detector systematics very different from traditional weak lensing measurements using optical CCDs. One of the non-linear detector effects observed in CCDs is the brighter-fatter effect (BFE), in which charge already accumulated in a pixel alters the electric field geometry and causes new charge to be deflected away from brighter pixels. Here we describe the formalism for measuring the BFE using flat field correlation functions in infrared detector arrays. The auto-correlation of CCD flat fields is often used to measure the BFE, but because the infrared detector arrays are read out with the charge "in place," the flat field correlations are dominated by capacitive cross-talk between neighboring pixels (the inter-pixel capacitance, or IPC). Conversely, if the BFE is present and one does not account for it, it can bias correlation measurements of the IPC and photon transfer measurements of the gain. We show that because the infrared detector arrays can be read out non-destructively, one can compute numerous cross-correlation functions between different time slices of the same flat exposures, and that correlations due to IPC and BFE leave distinct imprints. We generate a suite of simulated flat fields and show that the underlying IPC and BFE parameters can be extracted, even when both are present in the simulation. There are some biases in the BFE coefficients up to 12%, which are likely caused by higher order terms that are dropped from this analysis.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑