气体调制折射法(GAMOR)-消除漂移影响的能力

Gas modulation refractometry (GAMOR) - On its ability to eliminate the influence of drifts

Ove Axner, Isak Silander, Clayton Forssén, Yin Guo, Martin Zelan

摘要:

气体调制折射法(GAMOR)是一种基于双法布里-珀罗(FP)腔(DFPC)的技术,用于评估气体的折射活性、密度和压力,可以减轻传统折射法系统的显著限制,主要是与漂移相关的限制。当测量腔被抽空时,重复评估拍频提供了这样的条件,在该条件下,该方法不受系统中漂移的线性部分的影响,这些线性部分来自腔的长度变化以及来自气体泄漏和除气的线性部分。这意味着该技术仅受漂移的非线性部分的影响。这项工作提供了一个描述的原则背后的GAMOR方法,并阐述了其独特的属性的背景。基于简单的模型的漂移的温度在腔间隔和参考腔中的残余气体,这项工作预测,一个GAMOR系统,当用于评估放射性活度,可以维持显着的温度漂移和泄漏率,而不会受到明显的误差或不确定性的影响。腔间隔件可以在103 s内暴露于100 mK的温度波动,并且参考腔可以具有泄漏,该泄漏在几天的时间尺度上用气体填充,而不会在评估N2活度时提供3 x 10^(-12)的误差或不确定性,对于N2,01 ppm(百万分之一),因此为1 mPa。由于精心设计的系统通常具有小于这些的温度波动和泄漏率,因此可以得出结论,在实践中,在GAMOR方法中,腔长漂移、气体泄漏和放气不会产生任何明显的影响。

英文摘要:

Gas modulation refractometry (GAMOR) is a technique based on a dual-Fabry-Perot (FP) cavity (DFPC) for assessment of gas refractivity, density, and pressure that can alleviate significant limitations of conventional refractometry systems, predominantly those related to drifts. Repeated assessments of the beat frequency when the measurement cavity is evacuated provide conditions under which the methodology is immune to the linear parts of the drifts in the system, both those from length changes of the cavities and those from gas leaks and outgassing. This implies that the technique is solely influenced by the non-linear parts of the drifts. This work provides a description of the principle behind the GAMOR methodology and explicates the background to its unique property. Based on simple models of the drifts of the temperature in the cavity spacer and the residual gas in the reference cavity, this work predicts that a GAMOR system, when used for assessment of refractivity, can sustain significant temperature drifts and leakage rates without being affected by noticeable errors or uncertainties. The cavity spacer can be exposed to temperature fluctuations of 100 mK over 103 s, and the reference cavity can have a leakage that fills it up with gas on a timescale of days, without providing errors or uncertainties in the assessment of refractivity that are 3 x 10^(-12), which, for N2, corresponds to 0.01 ppm (parts per million) of the value under atmospheric pressure conditions, and thereby 1 mPa. Since well-designed systems often have temperature fluctuations and leakage rates that are smaller than these, it is concluded that there will, in practice, not be any appreciable influence from cavity length drifts, gas leaks, and outgassing in the GAMOR methodology.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑