In this work we propose a ResNet-based universal method for speckle reduction in optical coherence tomography (OCT) images. The proposed model contains 3 main modules: Convolution-BN-ReLU, Branch and Residual module. Unlike traditional algorithms, the model can learn from training data instead of selecting parameters manually such as noise level. Application of this proposed method to the OCT images shows a more than 22 dB signal-to-noise ratio improvement in speckle noise reduction with minimal structure blurring. The proposed method provides strong generalization ability and can process noisy other types of OCT images without retraining. It outperforms other filtering methods in suppressing speckle noises and revealing subtle features.
Optical coherence tomography (OCT) is an important interferometric diagnostic technique which provides cross-sectional views of the subsurface microstructure of biological tissues. However, the imaging quality of high-speed OCT is limited due to the large speckle noise. To address this problem, this paper proposes a multi-frame algorithmic method to denoise OCT volume. Mathematically, we build an optimization model which forces the temporally registered frames to be low rank, and the gradient in each frame to be sparse, under logarithmic image formation and noise variance constraints. Besides,…
Optical Coherence Tomography (OCT) is an emerging technique in the field of biomedical imaging, with applications in ophthalmology, dermatology, coronary imaging etc. Due to the underlying physics, OCT images usually suffer from a granular pattern, called speckle noise, which restricts the process of interpretation. Here, a sparse and low rank decomposition based method is used for speckle reduction in retinal OCT images. This technique works on input data that consists of several B-scans of the same location. The next step is the batch alignment of the images using a sparse and low-rank decom…
Optical Coherence Tomography (OCT) is an emerging technique in the field of biomedical imaging, with applications in ophthalmology, dermatology, coronary imaging etc. OCT images usually suffer from a granular pattern, called speckle noise, which restricts the process of interpretation. Therefore the need for speckle noise reduction techniques is of high importance. To the best of our knowledge, use of Independent Component Analysis (ICA) techniques has never been explored for speckle reduction of OCT images. Here, a comparative study of several ICA techniques (InfoMax, JADE, FastICA and SOBI) …
Optical Coherence Tomography allows ophthalmologist to obtain cross-section imaging of eye retina. Assisted with digital image analysis methods, effective disease detection could be performed. Various methods exist to extract feature from OCT images. The proposed study aims to compare the effectiveness of handcrafted and deep neural network features. The evaluated dataset consist of 32339 instances distributed in four classes, namely CNV, DME, DRUSEN, and NORMAL. The methods are Histogram of Oriented Gradient (HOG), Local Binary Pattern (LBP), DenseNet-169, and ResNet50. As a result, the deep …
Wayne State University(韦恩州立大学);Mayo Clinic(梅奥诊所);Wayne State University School of Medicine(韦恩州立大学医学院);Roma Tre University(罗马第三大学)
Optical coherence tomography (OCT) has become a favorable device in the Dermatology discipline due to its moderate resolution and penetration depth. OCT images however contain a grainy pattern, called speckle, due to the use of a broadband source in the configuration of OCT. So far, a variety of filtering (de-speckling) techniques is introduced to reduce speckle in OCT images. Most of these methods are generic and can be applied to OCT images of different tissues. The ambition of this work is to provide a de-speckling framework specialized for filtering skin tissues for the community to utiliz…
Noise in speckle-prone optical coherence tomography tends to obfuscate important details necessary for medical diagnosis. In this paper, a denoising approach that preserves disease characteristics on retinal optical coherence tomography images in ophthalmology is presented. By combining a deep convolutional autoencoder with a priorly trained ResNet image classifier as regularizer, the perceptibility of delicate details is encouraged and only information-less background noise is filtered out. With our approach, higher peak signal-to-noise ratios with $ \mathrm{PSNR} = 31.2\,\mathrm{dB} $ and hi…
Comparative Study of UNet-based Architectures for Liver Tumor Segmentation in Multi-Phase Contrast-Enhanced Computed Tomography
School of Computer Science and Engineering(计算机科学与工程学院);The Saigon International University(暹罗国际大学);School of Biomedical Engineering(生物医学工程学院);International University(国际大学);Vietnam National University HCMC(越南国家大学胡志明市分校)
Melbourne Data Analytics Platform(墨尔本数据分析平台);University of Melbourne(墨尔本大学)
Deep learning has been used to assist in the analysis of medical imaging. One such use is the classification of Computed Tomography (CT) scans when detecting for COVID-19 in subjects. This paper presents Cov3d, a three dimensional convolutional neural network for detecting the presence and severity of COVID19 from chest CT scans. Trained on the COV19-CT-DB dataset with human expert annotations, it achieves a macro f1 score of 0.9476 on the validation set for the task of detecting the presence of COVID19. For the task of classifying the severity of COVID19, it achieves a macro f1 score of 0.755…
Mohammed VI Polytechnic University(穆罕默德六世理工大学);Moulay Ismail University(穆莱·伊斯梅尔大学);University Mohammed V in Rabat(拉巴特穆罕默德五世大学);ENSIAS(国立统计与应用经济学院)
Recently, researchers, specialists, and companies around the world are rolling out deep learning and image processing-based systems that can fastly process hundreds of X-Ray and computed tomography (CT) images to accelerate the diagnosis of pneumonia such as SARS, COVID-19, and aid in its containment. Medical images analysis is one of the most promising research areas, it provides facilities for diagnosis and making decisions of a number of diseases such as MERS, COVID-19. In this paper, we present a comparison of recent Deep Convolutional Neural Network (DCNN) architectures for automatic bina…
Automated Prediction of Postoperative Pancreatic Fistula Using Preoperative Computed Tomography
Department of Surgery, Mayo Clinic, Rochester, MN, USA(梅奥诊所外科部,罗切斯特,明尼苏达州,美国);Department of Surgery, University of Auckland, Auckland, NZ(奥克兰大学外科部,奥克兰,新西兰);Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester, MN, USA(健康照护科学中心,梅奥诊所,罗切斯特,明尼苏达州,美国);Department of Artificial Intelligence(人工智能部)
Ghulam Ishaq Khan Institute of Engineering Sciences and Technology(古拉姆·伊沙克·汗工程科学与技术学院)
COVID-19 has been detrimental in terms of the number of fatalities and rising number of critical patients across the world. According to the UNDP (United National Development Programme) Socio-Economic programme, aimed at the COVID-19 crisis, the pandemic is far more than a health crisis: it is affecting societies and economies at their core. There has been greater developments recently in the chest X-ray-based imaging technique as part of the COVID-19 diagnosis especially using Convolution Neural Networks (CNN) for recognising and classifying images. However, given the limitation of supervised…
In this paper, we propose the use of Optical Coherence Tomography (OCT) imaging for the problem of iris presentation attack (PA) detection. We assess its viability by comparing its performance with respect to traditional iris imaging modalities, viz., near-infrared (NIR) and visible spectrum. OCT imaging provides a cross-sectional view of an eye, whereas traditional imaging provides 2D iris textural information. PA detection is performed using three state-of-the-art deep architectures (VGG19, ResNet50 and DenseNet121) to differentiate between bonafide and PA samples for each of the three imagi…
Optical Coherence Tomography (OCT) is one of the most emerging imaging modalities that has been used widely in the field of biomedical imaging. From its emergence in 1990's, plenty of hardware and software improvements have been made. Its applications range from ophthalmology to dermatology to coronary imaging etc. Here, the focus is on applications of OCT in ophthalmology and retinal imaging. OCT is able to non-invasively produce cross-sectional volume images of the tissues which are further used for analysis of the tissue structure and its properties. Due to the underlying physics, OCT image…
Optical coherence tomography (OCT) is a prevalent imaging technique for retina. However, it is affected by multiplicative speckle noise that can degrade the visibility of essential anatomical structures, including blood vessels and tissue layers. Although averaging repeated B-scan frames can significantly improve the signal-to-noise-ratio (SNR), this requires longer acquisition time, which can introduce motion artifacts and cause discomfort to patients. In this study, we propose a learning-based method that exploits information from the single-frame noisy B-scan and a pseudo-modality that is c…
Enhanced Denoising of Optical Coherence Tomography Images Using Residual U-Net
IIT Bhubaneswar(印度理工学院布巴内斯瓦尔分校);Aravind Eye Care Systems(阿拉文德眼科医疗系统);Singapore Eye Research Institute(新加坡眼科研究所);Duke-NUS Medical School(杜克-新加坡国立大学医学院);Yong Loo Lin School of Medicine, National University of Singapore(新加坡国立大学杨潞龄医学院)
本研究提出基于 Residual U-Net 架构的增强去噪模型,有效降低 OCT 图像中的散斑噪声并保留组织细节,在 ASOCT 和 PSOCT 两种模态上均显著提升了图像质量指标,助力更精确的临床诊断。
Friedrich-Alexander-Universität Erlangen-Nürnberg(埃尔朗根-纽伦堡大学);Massachusetts Institute of Technology(麻省理工学院)
Optical coherence tomography (OCT) enables high-resolution and non-invasive 3D imaging of the human retina but is inherently impaired by speckle noise. This paper introduces a spatio-temporal denoising algorithm for OCT data on a B-scan level using a novel quantile sparse image (QuaSI) prior. To remove speckle noise while preserving image structures of diagnostic relevance, we implement our QuaSI prior via median filter regularization coupled with a Huber data fidelity model in a variational approach. For efficient energy minimization, we develop an alternating direction method of multipliers …
National Taiwan University(台湾大学);Chang Gung Memorial Hospital(长庚纪念医院);Chang Gung University(长庚大学)
Automated vascular segmentation on optical coherence tomography angiography (OCTA) is important for the quantitative analyses of retinal microvasculature in neuroretinal and systemic diseases. Despite recent improvements, artifacts continue to pose challenges in segmentation. Our study focused on removing the speckle noise artifact from OCTA images when performing segmentation. Speckle noise is common in OCTA and is particularly prominent over large non-perfusion areas. It may interfere with the proper assessment of retinal vasculature. In this study, we proposed a novel Supervision Vessel Seg…
NVIDIA AI Technology Center(英伟达人工智能技术中心);National Taiwan Normal University(台湾师范大学)
Speckle noise is an inherent disturbance in coherent imaging systems such as digital holography, synthetic aperture radar, optical coherence tomography, or ultrasound systems. These systems usually produce only single observation per view angle of the same interest object, imposing the difficulty to leverage the statistic among observations. We propose a novel image restoration algorithm that can perform speckle noise removal without clean data and does not require multiple noisy observations in the same view angle. Our proposed method can also be applied to the situation without knowing the n…
University of Oxford(牛津大学);Big Data Institute(大数据研究所)
Diabetic retinopathy (DR) is a complication of diabetes, and one of the major causes of vision impairment in the global population. As the early-stage manifestation of DR is usually very mild and hard to detect, an accurate diagnosis via eye-screening is clinically important to prevent vision loss at later stages. In this work, we propose an ensemble method to automatically grade DR using ultra-wide optical coherence tomography angiography (UW-OCTA) images available from Diabetic Retinopathy Analysis Challenge (DRAC) 2022. First, we adopt the state-of-the-art classification networks, i.e., Res…
Friedrich-Alexander-Universität Erlangen-Nürnberg(弗里德里希-亚历山大大学埃尔朗根-纽伦堡分校);Universitätsklinikum Erlangen(埃尔朗根大学医院);Massachusetts Institute of Technology(麻省理工学院);e.solutions GmbH(e.solutions有限公司)
This paper introduces an universal and structure-preserving regularization term, called quantile sparse image (QuaSI) prior. The prior is suitable for denoising images from various medical imaging modalities. We demonstrate its effectiveness on volumetric optical coherence tomography (OCT) and computed tomography (CT) data, which show different noise and image characteristics. OCT offers high-resolution scans of the human retina but is inherently impaired by speckle noise. CT on the other hand has a lower resolution and shows high-frequency noise. For the purpose of denoising, we propose a var…
Tunable Wavelet Unit based Convolutional Neural Network in Optical Coherence Tomography Analysis Enhancement for Classifying Type of Epiretinal Membrane Surgery
University of California San Diego(加州大学圣迭戈分校);Jacobs Retina Center(雅各布视网膜中心)
ARCOS: Zero-shot Boundary Localization for Corneal Layer Segmentation Across Optical Coherence Tomography Devices
Laboratoire d’Optique et Biosciences, CNRS, INSERM, École polytechnique, Institut Polytechnique de Paris(光学与生物光学实验室,法国国家科学研究中心,法国健康与医学研究院,巴黎综合理工学院,巴黎理工学院);GRC 32, Transplantation et Thérapies Innovantes de la Cornée, Sorbonne Université, Centre Hospitalier National d’Ophtalmologie des Quinze-Vingts(GRC 32,角膜创新移植与治疗研究组,索邦大学,十五二十国家眼科中心)
Optical coherence tomography (OCT) is a prevalent non-invasive imaging method which provides high resolution volumetric visualization of retina. However, its inherent defect, the speckle noise, can seriously deteriorate the tissue visibility in OCT. Deep learning based approaches have been widely used for image restoration, but most of these require a noise-free reference image for supervision. In this study, we present a diffusion probabilistic model that is fully unsupervised to learn from noise instead of signal. A diffusion process is defined by adding a sequence of Gaussian noise to self-…
Speckle artifacts degrade image quality in virtually all modalities that utilize coherent energy, including optical coherence tomography, reflectance confocal microscopy, ultrasound, and widefield imaging with laser illumination. We present an adversarial deep learning framework for laser speckle reduction, called DeepLSR (https://durr.jhu.edu/DeepLSR), that transforms images from a source domain of coherent illumination to a target domain of speckle-free, incoherent illumination. We apply this method to widefield images of objects and tissues illuminated with a multi-wavelength laser, using l…
Exploration of Interpretability Techniques for Deep COVID-19 Classification using Chest X-ray Images
Otto von Guericke University Magdeburg(马格德堡奥托·冯·格里克大学);University of Barcelona(巴塞罗那大学);Universitätsklinikum Erlangen(埃尔兰根大学医院);Apollo Hospitals(阿波罗医院);HCG Cancer Centre(HCG癌症中心);Computer Vision Centre(计算机视觉中心)
The novel coronavirus 2019 (COVID-19) is a respiratory syndrome that resembles pneumonia. The current diagnostic procedure of COVID-19 follows reverse-transcriptase polymerase chain reaction (RT-PCR) based approach which however is less sensitive to identify the virus at the initial stage. Hence, a more robust and alternate diagnosis technique is desirable. Recently, with the release of publicly available datasets of corona positive patients comprising of computed tomography (CT) and chest X-ray (CXR) imaging; scientists, researchers and healthcare experts are contributing for faster and autom…
An Efficient Deep Learning Framework for Brain Stroke Diagnosis Using Computed Tomography Images
Department of Computer Science;Engineering, Bangladesh University, Mohammadpur, Dhaka - 1207, Bangladesh;School of Computing, Montclair State University, Montclair, NJ 07043, USA;Technology University, Tangail-1902, Dhaka, Bangladesh;School of Computing, Georgia Southern University, Statesboro, GA 30458, Georgia, USA;Engineering, National Institute of Textile Engineering;Research (NITER), \ Institute of Dhaka University, Savar, Dhaka-1350, Bangladesh;Faculty of Computer Science;Informatics, Berlin School of Business;Centre for Image;Vision Computing (CIVC), COE for Artificial Intelligence, Faculty of Artificial Intelligence;Engineering (FAIE), Multimedia University, Cyberjaya 63100, Malaysia;Engineering, The University of Aizu, Aizuwakamatsu, Fukushima, Japan
University of Trento(特伦托大学);Information Engineering University(信息工程大学);Space Engineering University NCO School(航天工程大学士官学校)
There are limited studies on the semantic segmentation of high-resolution Polarimetric Synthetic Aperture Radar (PolSAR) images due to the scarcity of training data and the inference of speckle noises. The Gaofen contest has provided open access of a high-quality PolSAR semantic segmentation dataset. Taking this chance, we propose a Multi-path ResNet (MP-ResNet) architecture for the semantic segmentation of high-resolution PolSAR images. Compared to conventional U-shape encoder-decoder convolutional neural network (CNN) architectures, the MP-ResNet learns semantic context with its parallel mul…
Christian Brothers University(基督教兄弟大学);University of Dayton(代顿大学)
With a Coronavirus disease (COVID-19) case count exceeding 10 million worldwide, there is an increased need for a diagnostic capability. The main variables in increasing diagnostic capability are reduced cost, turnaround or diagnosis time, and upfront equipment cost and accessibility. Two candidates for machine learning COVID-19 diagnosis are Computed Tomography (CT) scans and plain chest X-rays. While CT scans score higher in sensitivity, they have a higher cost, maintenance requirement, and turnaround time as compared to plain chest X-rays. The use of portable chest X-radiograph (CXR) is rec…
University of Nottingham(诺丁汉大学);Shenzhen University(深圳大学);Wuhan University of Technology(武汉理工大学);University of Leicester(莱斯特大学)
In this paper, we propose a novel retinal layer boundary model for segmentation of optical coherence tomography (OCT) images. The retinal layer boundary model consists of 9 open parametric contours representing the 9 retinal layers in OCT images. An intensity-based Mumford-Shah (MS) variational functional is first defined to evolve the retinal layer boundary model to segment the 9 layers simultaneously. By making use of the normals of open parametric contours, we construct equal sized adjacent narrowbands that are divided by each contour. Regional information in each narrowband can thus be int…
Deakin University(迪肯大学);National University of Singapore(新加坡国立大学)
The early and reliable detection of COVID-19 infected patients is essential to prevent and limit its outbreak. The PCR tests for COVID-19 detection are not available in many countries and also there are genuine concerns about their reliability and performance. Motivated by these shortcomings, this paper proposes a deep uncertainty-aware transfer learning framework for COVID-19 detection using medical images. Four popular convolutional neural networks (CNNs) including VGG16, ResNet50, DenseNet121, and InceptionResNetV2 are first applied to extract deep features from chest X-ray and computed tom…
Khulna University of Engineering and Technology(库尔纳工程技术大学)
In medical science, the use of computer science in disease detection and diagnosis is gaining popularity. Previously, the detection of disease used to take a significant amount of time and was less reliable. Machine learning (ML) techniques employed in recent biomedical researches are making revolutionary changes by gaining higher accuracy with more concise timing. At present, it is even possible to automatically detect diseases from the scanned images with the help of ML. In this research, we have taken such an attempt to detect retinal diseases from optical coherence tomography (OCT) X-ray i…
Singapore Eye Research Institute(新加坡眼科研究所);National University of Singapore(新加坡国立大学);Beihang University(北京航空航天大学);Duke-NUS Medical School(杜克-新加坡国立大学医学院)
Speckle noise and retinal shadows within OCT B-scans occlude important edges, fine textures and deep tissues, preventing accurate and robust diagnosis by algorithms and clinicians. We developed a single process that successfully removed both noise and retinal shadows from unseen single-frame B-scans within 10.4ms. Mean average gradient magnitude (AGM) for the proposed algorithm was 57.2% higher than current state-of-the-art, while mean peak signal to noise ratio (PSNR), contrast to noise ratio (CNR), and structural similarity index metric (SSIM) increased by 11.1%, 154% and 187% respectively c…
This paper evaluates the performance of supervised and unsupervised deep learning models for denoising positron emission tomography (PET) images in the presence of reduced acquisition times. Our experiments consider 212 studies (56908 images), and evaluate the models using 2D (RMSE, SSIM) and 3D (SUVpeak and SUVmax error for the regions of interest) metrics. It was shown that, in contrast to previous studies, supervised models (ResNet, Unet, SwinIR) outperform unsupervised models (pix2pix GAN and CycleGAN with ResNet backbone and various auxiliary losses) in the reconstruction of 2D PET images…
Divyadrishti Imaging Laboratory, IIT Roorkee, Indian Institute of Technology Roorkee(IIT Roorkee 的 Divyadrishti 成像实验室,印度理工学院 Roorkee)
Image data set from a multi-spectral animal imaging system is used to address two issues: (a) registering the oscillation in optical coherence tomography (OCT) images due to mouse eye movement and (b) suppressing the shadow region under the thick vessels/structures. Several classical and AI-based algorithms in combination are tested for each task to see their compatibility with data from the combined animal imaging system. Hybridization of AI with optical flow followed by Homography transformation is shown to be working (correlation value>0.7) for registration. Resnet50 backbone is shown to be…
Carnegie Mellon University(卡内基梅隆大学);University of Pittsburgh(匹兹堡大学)
Optical Coherence Tomography (OCT) is an imaging modality that has been widely adopted for visualizing corneal, retinal and limbal tissue structure with micron resolution. It can be used to diagnose pathological conditions of the eye, and for developing pre-operative surgical plans. In contrast to the posterior retina, imaging the anterior tissue structures, such as the limbus and cornea, results in B-scans that exhibit increased speckle noise patterns and imaging artifacts. These artifacts, such as shadowing and specularity, pose a challenge during the analysis of the acquired volumes as they…
National Heart and Lung Institute, Imperial College London(帝国理工学院国家心肺研究所);Cardiovascular Research Centre, Royal Brompton Hospital(皇家布朗普顿医院心血管研究中心)
Medical image classification and segmentation based on deep learning (DL) are emergency research topics for diagnosing variant viruses of the current COVID-19 situation. In COVID-19 computed tomography (CT) images of the lungs, ground glass turbidity is the most common finding that requires specialist diagnosis. Based on this situation, some researchers propose the relevant DL models which can replace professional diagnostic specialists in clinics when lacking expertise. However, although DL methods have a stunning performance in medical image processing, the limited datasets can be a challeng…
West Virginia University(西弗吉尼亚大学);Rockefeller Neuroscience Institute(洛克菲勒神经科学研究所);Georgia Institute of Technology(佐治亚理工学院);Twentieth Century Fox(二十世纪福克斯公司);Starfleet Academy(星际舰队学院)
In this paper, we design a Generative Adversarial Network (GAN)-based solution for super-resolution and segmentation of optical coherence tomography (OCT) scans of the retinal layers. OCT has been identified as a non-invasive and inexpensive modality of imaging to discover potential biomarkers for the diagnosis and progress determination of neurodegenerative diseases, such as Alzheimer's Disease (AD). Current hypotheses presume the thickness of the retinal layers, which are analyzable within OCT scans, can be effective biomarkers. As a logical first step, this work concentrates on the challeng…
Tracking the pose of instruments is a central problem in image-guided surgery. For microscopic scenarios, optical coherence tomography (OCT) is increasingly used as an imaging modality. OCT is suitable for accurate pose estimation due to its micrometer range resolution and volumetric field of view. However, OCT image processing is challenging due to speckle noise and reflection artifacts in addition to the images' 3D nature. We address pose estimation from OCT volume data with a new deep learning-based tracking framework. For this purpose, we design a new 3D convolutional neural network (CNN) …
Fractures occur in the shoulder area, which has a wider range of motion than other joints in the body, for various reasons. To diagnose these fractures, data gathered from Xradiation (X-ray), magnetic resonance imaging (MRI), or computed tomography (CT) are used. This study aims to help physicians by classifying shoulder images taken from X-ray devices as fracture / non-fracture with artificial intelligence. For this purpose, the performances of 26 deep learning-based pretrained models in the detection of shoulder fractures were evaluated on the musculoskeletal radiographs (MURA) dataset, and …
This paper presents a novel automated system that segments six sub-retinal layers from optical coherence tomography (OCT) image stacks of healthy patients and patients with diabetic macular edema (DME). First, each image in the OCT stack is denoised using a Wiener deconvolution algorithm that estimates the additive speckle noise variance using a novel Fourier-domain based structural error. This denoising method enhances the image SNR by an average of 12dB. Next, the denoised images are subjected to an iterative multi-resolution high-pass filtering algorithm that detects seven sub-retinal surfa…
Primary angle-closure disease (PACD) is a severe retinal disease, which might cause irreversible vision loss. In clinic, accurate identification of angle-closure and localization of the scleral spur's position on anterior segment optical coherence tomography (AS-OCT) is essential for the diagnosis of PACD. However, manual delineation might confine in low accuracy and low efficiency. In this paper, we propose an efficient and accurate end-to-end architecture for angle-closure classification and scleral spur localization. Specifically, we utilize a revised ResNet152 as our backbone to improve th…
At the present time Optical Coherence Tomography (OCT) is among the most commonly used non-invasive imaging methods for the acquisition of large volumetric scans of human retinal tissues and vasculature. To resolve decisive information from extracted OCT volumes and to make it applicable for further diagnostic analysis, the exact identification of retinal layer thicknesses serves as an essential task be done for each patient separately. However, the manual examination of multiple OCT scans in a row is a demanding and time consuming task, which results in a lengthy qualification process and is …
According to the World Health Organization, 285 million people worldwide live with visual impairment. The most commonly used imaging technique for diagnosis in ophthalmology is optical coherence tomography (OCT). However, analysis of retinal OCT requires trained ophthalmologists and time, making a comprehensive early diagnosis unlikely. A recent study established a diagnostic tool based on convolutional neural networks (CNN), which was trained on a large database of retinal OCT images. The performance of the tool in classifying retinal conditions was on par to that of trained medical experts. …
WAVE-UNET: Wavelength based Image Reconstruction method using attention UNET for OCT images
Institute of Optical Materials and Technologies, Bulgarian Academy of Sciences(保加利亚科学院光学材料与技术研究所);Faculty of Information Technology and Communication Sciences, Tampere University(坦佩雷大学信息技术与通信科学学院);Electronics and Telecommunications Research Institute(电子与电信研究所)