arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1902.10969physics.plasm-phphysics.class-ph
收藏

在WEST下部偏滤器中用嵌入的热测量进行的第一次热通量估算

First heat flux estimation in the lower divertor of WEST with embedded thermal measurements

J. Gaspar, Y. Corre, M. Firdaouss, J. Gardarein, J. Gerardin, J. Gunn, M. Houry, G. Laffont, T. Loarer, M. Missirlian, J. Morales, P. Moreau, C. Pocheau, E. Tsitrone, West Team

摘要:

研究了WEST托卡马克装置面向等离子体组件(PFC)中热电偶(TC)和光纤光栅(FBG)的表面热流估算。采用共轭梯度法(CGM)和伴随状态相结合的二维传热模型,计算了等离子体在PFC上的热流密度,给出了等离子体热流密度随时间的变化特征,并给出了热流密度衰减长度$λ^t_q$、热流密度分布区域$S^t$和撞击点位置$x_0$.作为第一步,五欧姆脉冲已被调查与不同的磁配置和偏滤器X-点的高度从44到68毫米从表面变化。尽管外侧移位,外部撞击点的相对位移以及来自TC/FBG系统的热通量衰减长度与磁平衡重建是一致的。

英文摘要:

The present paper deals with the surface heat flux estimation with thermocouples (TC) and fiber Bragg grating (FBG) embedded in the plasma facing components (PFC) of the WEST tokamak. A 2D heat transfer model combined with the conjugate gradient method (CGM) and the adjoint state is used to estimate the plasma heat flux deposited on the PFC. The plasma heat flux is characterized by the time evolution of its amplitude and spatial shape on the target (heat flux decay length $λ^t_q$, power spreading in the private flux region $S^t$ and the strike point location $x_0$). As a first step, five ohmic pulses have been investigated with different magnetic configuration and divertor X-point height varying from 44 to 68 mm from the surface. Despite an outboard shift, the relative displacements of the outer strike point as well as the heat flux decay length derived from the TC/FBG systems are consistent with the magnetic equilibrium reconstruction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑