从频率复用信号中提取大鼠坐骨神经神经活动时阻抗变化的初步研究

Extracting impedance changes from a frequency multiplexed signal during neural activity in sciatic nerve of rat: preliminary study in-vitro

J. Hope, K. Aristovich, C. A. R. Chapman, A. Volschenk, F. Vanholsbeeck, A. McDaid

摘要:

目的:建立适当的频率间隔和解调步骤,用于从外周神经中的频分复用(FDM)载波信号提取阻抗变化。方法:在安乐死后立即对尸体进行体外实验。通过刺激后爪中的神经诱发神经活动,同时注入载体信号,并通过在坐骨神经上植入双环神经套来获得记录。频率分析记录的复合动作电位(CAP)和提取的阻抗变化,后者获得使用已建立的解调方法,被用来确定合适的频率间隔的载波信号,带通滤波器(BPF)的带宽和顺序,频率复用信号。主要结果:CAP和阻抗变化分别在200 - 500 Hz和100 - 200 Hz频段占主导地位。引入Tukey窗口来消除Gibbs现象中的振铃。选择+/- 750 Hz BPF带宽,以涵盖阻抗变化的频率功率的99.99%。为了避免来自相邻载波信号的振铃,模型预测的最小BPF阶数对于2kHz间隔为16,对于4kHz间隔为10,而FDM实验验证的BPF阶数分别为12和8。对于以相邻信号为中心的陷波滤波器,2 kHz和4 kHz分别需要至少6或4阶的BPF。重要性:研究结果建立了用于FDM电阻抗断层扫描(EIT)实验的驱动频率间隔和解调设置,以及它们的选择框架,并首次证明了周围神经上神经活动的FDM-EIT的可行性,这将是未来实时神经EIT系统和基于EIT的神经假体接口的一个核心方面。

英文摘要:

Objective: Establish suitable frequency spacing and demodulation steps to use when extracting impedance changes from frequency division multiplexed (FDM) carrier signals in peripheral nerve. Approach: Experiments were performed in-vitro on cadavers immediately following euthanasia. Neural activity was evoked via stimulation of nerves in the hind paw, while carrier signals were injected, and recordings obtained, with a dual ring nerve cuff implanted on the sciatic nerve. Frequency analysis of recorded compound action potentials (CAPs) and extracted impedance changes, with the latter obtained using established demodulation methods, were used to determine suitable frequency spacing of carrier signals, and bandpass filter (BPF) bandwidth and order, for a frequency multiplexed signal. Main results: CAPs and impedance changes were dominant in the frequency band 200 to 500 Hz and 100 to 200 Hz, respectively. A Tukey window was introduced to remove ringing from Gibbs phenomena. A +/- 750 Hz BPF bandwidth was selected to encompass 99.99 % of the frequency power of the impedance change. Modelling predicted a minimum BPF order of 16 for 2 kHz spacing, and 10 for 4 kHz spacing, were required to avoid ringing from the neighbouring carrier signal, while FDM experiments verified BPF orders of 12 and 8, respectively, were required. With a notch filter centred on the neighbouring signal, a BPF order of at least 6 or 4 was required for 2 and 4 kHz, respectively. Significance: The results establish drive frequency spacing and demodulation settings for use in FDM electrical impedance tomography (EIT) experiments, as well as a framework for their selection, and, for the first time, demonstrates the viability of FDM-EIT of neural activity on peripheral nerve, which will be a central aspect of future real-time neural-EIT systems and EIT-based neural prosthetics interfaces.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑